Literature DB >> 12582369

Magnetic resonance imaging diagnosis of the temporomandibular joint in patients with orthodontic appliances.

Yoshie Okano1, Mitsuaki Yamashiro, Takashi Kaneda, Kazutaka Kasai.   

Abstract

OBJECTIVE: The purpose of this study was to investigate the accuracy of magnetic resonance imaging diagnosis of the temporomandibular joint in those with orthodontic appliances by comparing magnetic resonance images of the temporomandibular joints with and without orthodontic appliances. STUDY
DESIGN: Magnetic resonance imaging was performed in a total of 20 temporomandibular joints before and after the insertion of 6 kinds of orthodontic appliances (types 1-6), and the magnetic resonance images were compared.
RESULTS: With respect to disk position, the diagnostic accuracy was 80%, 75%, 70%, 70%, 65%, and 60% in order from type 1 through type 6. The distribution of stages for the assessment of condylar configurations was 80%, 55%, 40%, 40%, 20%, and 10% in order from type 1 through type 6. No significant changes were found in the condylar head marrow signals.
CONCLUSION: Magnetic resonance imaging is performed in orthodontic patients preferably by using ceramic brackets in the front teeth and direct bonding tubes in the molar teeth while removing arch wires.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12582369     DOI: 10.1067/moe.2003.37

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  14 in total

1.  Orthodontic springs and auxiliary appliances: assessment of magnetic field interactions associated with 1.5 T and 3 T magnetic resonance systems.

Authors:  J Kemper; A N Priest; D Schulze; B Kahl-Nieke; G Adam; A Klocke
Journal:  Eur Radiol       Date:  2006-06-29       Impact factor: 5.315

2.  Radiofrequency-induced heating near fixed orthodontic appliances in high field MRI systems at 3.0 Tesla.

Authors:  Marc Regier; Jörn Kemper; Michael G Kaul; Markus Feddersen; Gerhard Adam; Bärbel Kahl-Nieke; Arndt Klocke
Journal:  J Orofac Orthop       Date:  2009-12-04       Impact factor: 1.938

Review 3.  Recent advances in imaging technologies in dentistry.

Authors:  Naseem Shah; Nikhil Bansal; Ajay Logani
Journal:  World J Radiol       Date:  2014-10-28

4.  Predictability of magnetic susceptibility artifacts from metallic orthodontic appliances in magnetic resonance imaging.

Authors:  F Blankenstein; B T Truong; A Thomas; N Thieme; C Zachriat
Journal:  J Orofac Orthop       Date:  2014-11-26       Impact factor: 1.938

5.  MRI with intraoral orthodontic appliance-a comparative in vitro and in vivo study of image artefacts at 1.5 T.

Authors:  C Zachriat; P Asbach; K I Blankenstein; I Peroz; F H Blankenstein
Journal:  Dentomaxillofac Radiol       Date:  2015-03-03       Impact factor: 2.419

6.  [Metal objects of the head and neck region in magnetic resonance imaging : Survey among radiologists].

Authors:  Ulrike Kielburg; Felix H Blankenstein
Journal:  Radiologe       Date:  2019-10       Impact factor: 0.635

7.  Ceramic brackets and low friction : A possible synergy in patients requiring multiple MRI scanning.

Authors:  Matteo Camporesi; Mariana Bulhoes Galvão; André Tortamano; Gladys Cristina Dominguez; Nicolò Defraia; Efisio Defraia; Lorenzo Franchi
Journal:  J Orofac Orthop       Date:  2016-04-20       Impact factor: 1.938

8.  Magnetic permeability as a predictor of the artefact size caused by orthodontic appliances at 1.5 T magnetic resonance imaging.

Authors:  Felix H Blankenstein; Patrick Asbach; Florian Beuer; Johannes Glienke; Stefan Mayer; Christine Zachriat
Journal:  Clin Oral Investig       Date:  2016-03-17       Impact factor: 3.573

Review 9.  Should the orthodontic brackets always be removed prior to magnetic resonance imaging (MRI)?

Authors:  Arash Poorsattar-Bejeh Mir; Manouchehr Rahmati-Kamel
Journal:  J Oral Biol Craniofac Res       Date:  2015-09-15

10.  Interactions between magnetic resonance imaging and dental material.

Authors:  Chalakuzhiyl Abraham Mathew; Sudhakara Maller
Journal:  J Pharm Bioallied Sci       Date:  2013-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.