Flavio Uribe1, Rana Mehr2, Ajay Mathur3, Nandakumar Janakiraman4, Veerasathpurush Allareddy5.
Abstract
BACKGROUND: The purpose of this pilot study was to evaluate the failure rates of mini-implants placed in the infrazygomatic region and to evaluate factors that affect their stability.Entities:
Keywords: Failure rate; Infrazygomatic mini-implants; Stability
Mesh:
Substances:
Year: 2015 PMID: 26373730 PMCID: PMC4571029 DOI: 10.1186/s40510-015-0100-2
Source DB: PubMed Journal: Prog Orthod ISSN: 1723-7785 Impact factor: 2.750
Failure rates by characteristics of patients
| Characteristic | Total | Failure rate (%) | |
|---|---|---|---|
| Age | <18 years | 29 | 20.69 |
| ≥18 years | 26 | 23.08 | |
| Gender | Male | 13 | 38.46 |
| Female | 42 | 16.67 | |
| Presence of medical condition | Yes | 6 | 50 |
| No | 49 | 18.37 | |
| Lomas (Mondeal, Tuttligen, Germany) | Yes | 43 | 18.60 |
| No | 12 | 33.33 | |
| Diameter of implant | 1.50 or 1.80 | 10 | 30 |
| 2.00 or 2.30 | 45 | 20 | |
| Length of implant | 6 to 8 mm | 13 | 30.77 |
| 9 mm | 42 | 19.05 | |
| Force magnitude | 150 g | 12 | 16.67 |
| >150 g | 43 | 23.26 | |
| Type of movement | Purely intrusive | 25 | 16 |
| All others | 30 | 26.67 | |
| Oral hygiene | Poor | 14 | 35.71 |
| Good or fair | 41 | 17.07 | |
| Operator experience | Experienced | 11 | 18.18 |
| Inexperienced | 44 | 22.73 | |
| Use of pilot hole | Yes | 22 | 13.64 |
| No | 33 | 27.27 | |
| Side of implant | Left | 28 | 25 |
| Right | 27 | 18.52 | |
Fig. 1Mini-implant placed in the IZ region of the maxilla
Estimates from univariate regression analysis (independent association between predictor variables and failed implants)
| Predictor variable | Estimate | Odds ratio |
| |
|---|---|---|---|---|
| Age | <18 years | −0.1182 | 0.89 | 0.86 |
| ≥18 years | Reference | |||
| Gender | Female | −1.1383 | 0.32 | 0.11 |
| Male | Reference | |||
| Presence of medical condition | Yes | 1.50 | 4.48 | 0.14 |
| No | Reference | |||
| Lomas (Mondeal, Tuttligen, Germany) | Yes | −0.7983 | 0.45 | 0.31 |
| No | Reference | |||
| Diameter of implant | 1.50 or 1.80 | 0.5630 | 1.76 | 0.40 |
| 2.00 or 2.30 | Reference | |||
| Length of implant | 6 to 8 mm | 0.7078 | 2.03 | 0.37 |
| 9 mm | Reference | |||
| Force | 150 g | −0.4282 | 0.65 | 0.59 |
| >150 g | Reference | |||
| Type of movement | Purely intrusive | −0.6377 | 0.53 | 0.34 |
| All others | Reference | |||
| Oral hygiene | Poor | 1.0269 | 2.79 | 0.09 |
| Good | Reference | |||
| Operator experience | Experienced | −0.3145 | 0.73 | 0.6848 |
| Inexperienced | Reference | |||
| Use of pilot hole | Yes | −0.8610 | 0.42 | 0.32 |
| No | Reference | |||
| Side of implant | Left | 0.3962 | 1.49 | 0.53 |
| Right | Reference | |||