Literature DB >> 17346590

A computed tomographic image study on the thickness of the infrazygomatic crest of the maxilla and its clinical implications for miniscrew insertion.

Eric J W Liou1, Po-Hsun Chen, Yu-Chih Wang, James Chen-Yi Lin.   

Abstract

INTRODUCTION: The purpose of this study was to measure the thickness of the infrazygomatic (IZ) crest above the maxillary first molar at different angles and positions to the maxillary occlusal plane. These measurements were then used to derive clinical implications and guidance for inserting miniscrews in the IZ crest without injuring the mesiobuccal root of the maxillary first molar.
METHODS: Computed tomographic images of 16 adults were used. For each subject, on the coronal slice of the computed tomographic image containing the IZ crest and mesiobuccal root of the maxillary first molar, the IZ crest thickness and the miniscrew insertion position were measured by postulating that the miniscrew would be inserted at each 5 degrees increment from 40 degrees to 75 degrees to the maxillary occlusal plane.
RESULTS: The IZ crest thickness above the maxillary first molar ranged from 5.2 +/- 1.1 mm to 8.8 +/- 2.3 mm, measured at 40 degrees to 75 degrees to the maxillary occlusal plane and 13 to 17 mm above the maxillary occlusal plane.
CONCLUSIONS: By adopting 6 mm as the minimal IZ crest thickness for sustaining a miniscrew well throughout treatment and avoiding injury to the mesiobuccal root of the maxillary first molar, the clinical implication for miniscrew placement in the IZ crest of an adult is to insert it 14 to 16 mm above the maxillary occlusal plane and the maxillary first molar at an angle of 55 degrees to 70 degrees to the maxillary occlusal plane.

Mesh:

Year:  2007        PMID: 17346590     DOI: 10.1016/j.ajodo.2005.04.044

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  16 in total

1.  Bone condition of the maxillary zygomatic process prior to orthodontic anchorage plate fixation.

Authors:  T M Präger; H G Brochhagen; R Mischkowski; P G Jost-Brinkmann; R Müller-Hartwich
Journal:  J Orofac Orthop       Date:  2014-11-26       Impact factor: 1.938

2.  Zygomatic mini-implant for Class II correction in growing patients.

Authors:  M M El-Dawlatly; A M Abou-El-Ezz; F A El-Sharaby; Y A Mostafa
Journal:  J Orofac Orthop       Date:  2014-05-15       Impact factor: 1.938

3.  Accuracy of two orthodontic mini-implant templates in the infrazygomatic crest zone: a prospective cohort study.

Authors:  Li Su; Hui Song; Xiaofeng Huang
Journal:  BMC Oral Health       Date:  2022-06-24       Impact factor: 3.747

4.  Diagnostic reliability of low dose multidetector CT and cone beam CT in maxillofacial trauma-an experimental blinded and randomized study.

Authors:  Romke Rozema; Michiel Hj Doff; Peter Ma van Ooijen; Douwe Postmus; Henriëtte E Westerlaan; Martijn F Boomsma; Baucke van Minnen
Journal:  Dentomaxillofac Radiol       Date:  2018-05-31       Impact factor: 2.419

5.  An evaluation of insertion sites for mini-implants: a micro - CT study of human autopsy material.

Authors:  Morten G Laursen; Birte Melsen; Paolo M Cattaneo
Journal:  Angle Orthod       Date:  2012-08-27       Impact factor: 2.079

6.  Dentofacial effects of two facemask therapies for maxillary protraction.

Authors:  Yuan Shu Ge; Jin Liu; Lin Chen; Jian Li Han; Xin Guo
Journal:  Angle Orthod       Date:  2012-05-28       Impact factor: 2.079

7.  Tomographic evaluation of infrazygomatic crest for orthodontic anchorage in different vertical and sagittal skeletal patterns.

Authors:  Alana Tavares; Iêda-Margarida Crusoé-Rebello; Frederico-Sampaio Neves
Journal:  J Clin Exp Dent       Date:  2020-11-01

8.  Failure rates of mini-implants placed in the infrazygomatic region.

Authors:  Flavio Uribe; Rana Mehr; Ajay Mathur; Nandakumar Janakiraman; Veerasathpurush Allareddy
Journal:  Prog Orthod       Date:  2015-09-15       Impact factor: 2.750

9.  Are temporary anchorage devices truly effective in the treatment of skeletal open bites?

Authors:  Hakan Turkkahraman; Mehmet Sarioglu
Journal:  Eur J Dent       Date:  2016 Oct-Dec

10.  Assessing bone thickness in the infrazygomatic crest area aiming the orthodontic miniplates positioning: a tomographic study.

Authors:  Aline Rode Santos; Marcelo Castellucci; Iêda Margarida Crusoé-Rebello; Márcio Costa Sobral
Journal:  Dental Press J Orthod       Date:  2017 Jul-Aug
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.