Five-year experience with orthodontic miniscrew implants: a retrospective investigation of factors influencing success rates.

Joanna Antoszewska1, Moschos A Papadopoulos, Hyo-Sang Park, Björn Ludwig.   

Abstract

INTRODUCTION: Anchorage control is important for efficient orthodontic treatment with fixed appliances. Successful osseointegration encouraged many orthodontists to use dental implants as stationary anchorage units for force application. However, their use has some drawbacks, which led to the development of miniscrew implants (MIs). Our aim was to investigate factors significantly contributing to the success rates of MIs in various orthodontic treatment procedures in white patients.
METHODS: In total, 350 self-tapping (187 Abso Anchor [Dentos, Daegu, South Korea] and 163 Ortho Easy Pin [Forestadent, Pforzheim, Germany]) MIs used to reinforce orthodontic anchorage and placed in 130 consecutively chosen patients were assessed retrospectively. Clinical variables possibly influencing the success rates of MIs were categorized into patient-related, implant-related, location-related, and orthodontic-related. Statistical evaluation included descriptive statistics and survival analysis. The survival curves of the MIs with respect to the various factors were estimated and plotted by using the Kaplan-Meier product-limit estimate. The MI survival distributions for each factor were compared with the log rank test for simple comparisons or the Cox regression for multiple variables.
RESULTS: The overall success rates of MIs that remained stable during a mean treatment time of 19.2 +/- 2.3 months was 93.43%; this was considerably higher than in previous reports. Only a few factors were found to be associated with statistically significant higher success rates of MIs, including deep bites, placement in the attached gingiva of the maxilla, and en-masse distalization of teeth.
CONCLUSIONS: The success rates of MIs in white patients were greater than the corresponding rates reported for Asian patients. Our results confirm the effectiveness of orthodontic MIs as temporary anchorage reinforcement devices and suggest various clinical factors as potential causes of failure.

Entities:  

Mesh:

Year:  2009        PMID: 19651342     DOI: 10.1016/j.ajodo.2009.03.031

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  22 in total

1.  Effects of low-intensity laser therapy over mini-implants success rate in pigs.

Authors:  Aguinaldo S Garcez; Selly Sayuri Suzuki; Elisabeth Ferreira Martinez; Mylene Garcez Iemini; Hideo Suzuki
Journal:  Lasers Med Sci       Date:  2013-08-09       Impact factor: 3.161

2.  Upper molar distalization with skeletally anchored TopJet appliance.

Authors:  Bernhard C Pseiner; Anne Wunderlich; Josef W Freudenthaler
Journal:  J Orofac Orthop       Date:  2014-01-19       Impact factor: 1.938

3.  Survey of orthodontists' attitudes and experiences regarding miniscrew implants.

Authors:  Jeffrey D Hyde; Gregory J King; Geoffrey M Greenlee; Charles Spiekerman; Greg J Huang
Journal:  J Clin Orthod       Date:  2010-08

4.  Patient expectations, acceptance and preferences in treatment with orthodontic mini-implants. A randomly controlled study. Part I: insertion techniques.

Authors:  Sandra Lehnen; Fraser McDonald; Christoph Bourauel; Martin Baxmann
Journal:  J Orofac Orthop       Date:  2011-03       Impact factor: 1.938

5.  Stability comparison between commercially available mini-implants and a novel design: part 1.

Authors:  Christine Hong; Haofu Lee; Richard Webster; Jinny Kwak; Benjamin M Wu; Won Moon
Journal:  Angle Orthod       Date:  2011-02-09       Impact factor: 2.079

6.  3-D Evaluation of temporary skeletal anchorage sites in the maxilla.

Authors:  Humberto Zago; Ricardo-de Lima Navarro; Vinicius Laranjeira; Thais-Maria-Freire Fernandes; Ana-Cláudia-de Castro-Ferreira Conti; Paula-Vanessa-Pedron Oltramari
Journal:  J Clin Exp Dent       Date:  2021-11-01

7.  Root proximity and cortical bone thickness effects on the success rate of orthodontic micro-implants using cone beam computed tomography.

Authors:  Kyung-Inn Min; Sang-Cheol Kim; Kyung-Hwa Kang; Jin-Hyoung Cho; Eon-Hwa Lee; Na-Young Chang; Jong-Moon Chae
Journal:  Angle Orthod       Date:  2012-03-14       Impact factor: 2.079

8.  Effect of Low-Level Laser Therapy on Peri-Miniscrew Fluid Prostaglandin E2 and Substance P Levels: A Controlled Clinical Trial.

Authors:  Özer Alkan; Yeşim Kaya; Esra Yüksek; Ahmet Ufuk Kömüroglu
Journal:  Turk J Orthod       Date:  2021-03-01

9.  In vivo evaluation of immediately loaded stainless steel and titanium orthodontic screws in a growing bone.

Authors:  Kerstin Gritsch; Norbert Laroche; Jeanne-Marie Bonnet; Patrick Exbrayat; Laurent Morgon; Muriel Rabilloud; Brigitte Grosgogeat
Journal:  PLoS One       Date:  2013-10-04       Impact factor: 3.240

10.  Periodontopathogens around the surface of mini-implants removed from orthodontic patients.

Authors:  André Tortamano; Gladys Cristina Dominguez; Ana Cristina Soares Santos Haddad; Fabio Daumas Nunes; Mônica Nacao; Camillo Morea
Journal:  Angle Orthod       Date:  2012-07       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.