Modeling Plasma-to-Interstitium Glucose Kinetics from Multitracer Plasma and Microdialysis Data.

Michele Schiavon1, Chiara Dalla Man1, Simmi Dube2, Michael Slama2, Yogish C Kudva2, Thomas Peyser3, Ananda Basu2, Rita Basu2, Claudio Cobelli1.   

Abstract

BACKGROUND: Quantitative assessment of the dynamic relationship between plasma and interstitial fluid (ISF) glucose and the estimation of the plasma-to-ISF delay are of major importance to determine the accuracy of subcutaneous glucose sensors, an essential component of open- and closed-loop therapeutic systems for type 1 diabetes mellitus (T1DM). The goal of this work is to develop a model of plasma-to-ISF glucose kinetics from multitracer plasma and interstitium data, obtained by microdialysis, in healthy and T1DM subjects, under fasting conditions.
MATERIALS AND METHODS: A specific experimental design, combining administration of multiple tracers with the microdialysis technique, was used to simultaneously frequently collect plasma and ISF data. Linear time-invariant compartmental modeling was used to describe glucose kinetics from the tracer data because the system is in steady state.
RESULTS: A two-compartment model was shown accurate and was identified from both plasma and ISF data. An "equilibration time" between plasma and ISF of 9.1 and 11.0 min (median) in healthy and T1DM subjects, respectively, was calculated.
CONCLUSIONS: We have demonstrated that, in steady-state condition, the glucose plasma-to-ISF kinetics can be modeled with a linear two-compartment model and that the "equilibration time" between the two compartments can be estimated with precision. Future studies will assess plasma-to-interstitium glucose kinetics during glucose and insulin perturbations in both healthy and T1DM subjects.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26313215      PMCID: PMC4649763          DOI: 10.1089/dia.2015.0119

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  22 in total

1.  Determination of time delay between blood and interstitial adipose tissue glucose concentration change by microdialysis in healthy volunteers.

Authors:  K J Wientjes; A J Schoonen
Journal:  Int J Artif Organs       Date:  2001-12       Impact factor: 1.595

2.  Use of subcutaneous interstitial fluid glucose to estimate blood glucose: revisiting delay and sensor offset.

Authors:  Kerstin Rebrin; Norman F Sheppard; Garry M Steil
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

3.  Accuracy of the 5-day FreeStyle Navigator Continuous Glucose Monitoring System: comparison with frequent laboratory reference measurements.

Authors:  Richard L Weinstein; Sherwyn L Schwartz; Ronald L Brazg; Jolyon R Bugler; Thomas A Peyser; Geoffrey V McGarraugh
Journal:  Diabetes Care       Date:  2007-03-02       Impact factor: 19.112

4.  Analysis of time lags and other sources of error of the DexCom SEVEN continuous glucose monitor.

Authors:  Apurv Kamath; Aarthi Mahalingam; James Brauker
Journal:  Diabetes Technol Ther       Date:  2009-11       Impact factor: 6.118

Review 5.  Who needs an artificial pancreas? (?).

Authors:  Janet Winikoff; Andrew Drexler
Journal:  J Diabetes       Date:  2013-05-29       Impact factor: 4.006

6.  Time lag of glucose from intravascular to interstitial compartment in type 1 diabetes.

Authors:  Ananda Basu; Simmi Dube; Sona Veettil; Michael Slama; Yogish C Kudva; Thomas Peyser; Rickey E Carter; Claudio Cobelli; Rita Basu
Journal:  J Diabetes Sci Technol       Date:  2014-10-10

7.  Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring.

Authors:  B Aussedat; M Dupire-Angel; R Gifford; J C Klein; G S Wilson; G Reach
Journal:  Am J Physiol Endocrinol Metab       Date:  2000-04       Impact factor: 4.310

Review 8.  The artificial pancreas: current status and future prospects in the management of diabetes.

Authors:  Thomas Peyser; Eyal Dassau; Marc Breton; Jay S Skyler
Journal:  Ann N Y Acad Sci       Date:  2014-04       Impact factor: 5.691

Review 9.  Artificial pancreas: past, present, future.

Authors:  Claudio Cobelli; Eric Renard; Boris Kovatchev
Journal:  Diabetes       Date:  2011-11       Impact factor: 9.461

10.  Time lag of glucose from intravascular to interstitial compartment in humans.

Authors:  Ananda Basu; Simmi Dube; Michael Slama; Isabel Errazuriz; Jose Carlos Amezcua; Yogish C Kudva; Thomas Peyser; Rickey E Carter; Claudio Cobelli; Rita Basu
Journal:  Diabetes       Date:  2013-09-05       Impact factor: 9.461

View more
  9 in total

1.  Discrepancies Between Blood Glucose and Interstitial Glucose: Technological Artifacts or Physiology: A Reply.

Authors:  Eberhard Biermann
Journal:  J Diabetes Sci Technol       Date:  2018-05-20

2.  Glucose Monitoring in Individuals With Diabetes Using a Long-Term Implanted Sensor/Telemetry System and Model.

Authors:  Joseph Y Lucisano; Timothy L Routh; Joe T Lin; David A Gough
Journal:  IEEE Trans Biomed Eng       Date:  2016-10-19       Impact factor: 4.538

3.  A Comparison of Time Delay in Three Continuous Glucose Monitors for Adolescents and Adults.

Authors:  Manasi Sinha; Katherine M McKeon; Savan Parker; Laura G Goergen; Hui Zheng; Firas H El-Khatib; Steven J Russell
Journal:  J Diabetes Sci Technol       Date:  2017-05-01

Review 4.  Microdialysis techniques and microdialysis-based patient-near diagnostics.

Authors:  Mark Thomas O'Connell; Jan Krejci
Journal:  Anal Bioanal Chem       Date:  2022-01-14       Impact factor: 4.142

5.  Interstitial Fluid Glucose Is Not Just a Shifted-in-Time but a Distorted Mirror of Blood Glucose: Insight from an In Silico Study.

Authors:  Claudio Cobelli; Michele Schiavon; Chiara Dalla Man; Ananda Basu; Rita Basu
Journal:  Diabetes Technol Ther       Date:  2016-06-02       Impact factor: 6.118

6.  A comparison of adipose tissue interstitial glucose and venous blood glucose during postprandial resistance exercise in patients with type 2 diabetes.

Authors:  Timothy D Heden; Ying Liu; Jill A Kanaley
Journal:  J Appl Physiol (1985)       Date:  2017-09-28

Review 7.  Calibration of Minimally Invasive Continuous Glucose Monitoring Sensors: State-of-The-Art and Current Perspectives.

Authors:  Giada Acciaroli; Martina Vettoretti; Andrea Facchinetti; Giovanni Sparacino
Journal:  Biosensors (Basel)       Date:  2018-03-13

8.  Limits to the Evaluation of the Accuracy of Continuous Glucose Monitoring Systems by Clinical Trials.

Authors:  Patrick Schrangl; Florian Reiterer; Lutz Heinemann; Guido Freckmann; Luigi Del Re
Journal:  Biosensors (Basel)       Date:  2018-05-18

9.  Development of an Error Model for a Factory-Calibrated Continuous Glucose Monitoring Sensor with 10-Day Lifetime.

Authors:  Martina Vettoretti; Cristina Battocchio; Giovanni Sparacino; Andrea Facchinetti
Journal:  Sensors (Basel)       Date:  2019-12-03       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.