Literature DB >> 10751207

Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring.

B Aussedat1, M Dupire-Angel, R Gifford, J C Klein, G S Wilson, G Reach.   

Abstract

The changes in plasma glucose concentration and in interstitial glucose concentration, determined with a miniaturized subcutaneous glucose sensor, were investigated in anesthetized nondiabetic rats. Interstitial glucose was estimated through two different calibration procedures. First, after a glucose load, the magnitude of the increase in interstitial glucose, estimated through a one-point calibration procedure, was 70% of that in plasma glucose. We propose that this is due to the effect of endogenous insulin on peripheral glucose uptake. Second, during the spontaneous secondary decrease in plasma glucose after the glucose load, interstitial glucose decreased faster than plasma glucose, which may also be due to the effect of insulin on peripheral glucose uptake. Third, during insulin-induced hypoglycemia, the decrease in interstitial glucose was less marked than that of plasma glucose, suggesting that hypoglycemia suppressed transfer of glucose into the interstitial tissue; subsequently, interstitial glucose remained lower than plasma glucose during its return to basal value, suggesting that the stimulatory effect of insulin on peripheral glucose uptake was protracted. If these observations obtained in rats are relevant to human physiology, such discrepancies between plasma and interstitial glucose concentration may have major implications for the use of a subcutaneous glucose sensor in continuous blood glucose monitoring in diabetic patients.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10751207     DOI: 10.1152/ajpendo.2000.278.4.E716

Source DB:  PubMed          Journal:  Am J Physiol Endocrinol Metab        ISSN: 0193-1849            Impact factor:   4.310


  46 in total

1.  Injectable hydrogel microbeads for fluorescence-based in vivo continuous glucose monitoring.

Authors:  Hideaki Shibata; Yun Jung Heo; Teru Okitsu; Yukiko Matsunaga; Tetsuro Kawanishi; Shoji Takeuchi
Journal:  Proc Natl Acad Sci U S A       Date:  2010-10-04       Impact factor: 11.205

2.  Modeling Plasma-to-Interstitium Glucose Kinetics from Multitracer Plasma and Microdialysis Data.

Authors:  Michele Schiavon; Chiara Dalla Man; Simmi Dube; Michael Slama; Yogish C Kudva; Thomas Peyser; Ananda Basu; Rita Basu; Claudio Cobelli
Journal:  Diabetes Technol Ther       Date:  2015-08-27       Impact factor: 6.118

3.  Effects of pioglitazone and insulin on tight glycaemic control assessed by the continuous glucose monitoring system : a monocentric, parallel-cohort study.

Authors:  Wolfgang Jung; Sigrun Jung
Journal:  Clin Drug Investig       Date:  2005       Impact factor: 2.859

4.  Graphical and numerical evaluation of continuous glucose sensing time lag.

Authors:  Boris P Kovatchev; Devin Shields; Marc Breton
Journal:  Diabetes Technol Ther       Date:  2009-03       Impact factor: 6.118

5.  Recent advances in continuous glucose monitoring: biocompatibility of glucose sensors for implantation in subcutis.

Authors:  Peter H Kvist; Henrik E Jensen
Journal:  J Diabetes Sci Technol       Date:  2007-09

6.  Signal processing algorithms implementing the "smart sensor" concept to improve continuous glucose monitoring in diabetes.

Authors:  Andrea Facchinetti; Giovanni Sparacino; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2013-09-01

7.  Professional continuous glucose monitoring in subjects with type 1 diabetes: retrospective hypoglycemia detection.

Authors:  Morten Hasselstrøm Jensen; Toke Folke Christensen; Lise Tarnow; Zeinab Mahmoudi; Mette Dencker Johansen; Ole Kristian Hejlesen
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

8.  Acute in vivo performance evaluation of the fluorescence affinity sensor in the intravascular and interstitial space in Swine.

Authors:  Ralph Dutt-Ballerstadt; Colton Evans; Arun P Pillai; Ashok Gowda; Roger McNichols; Jesse Rios; William Cohn
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

9.  Hypoglycemia Reduction and Accuracy of Continuous Glucose Monitoring.

Authors:  Boris P Kovatchev
Journal:  Diabetes Technol Ther       Date:  2015-05-15       Impact factor: 6.118

10.  Assessment of a Noninvasive Chronic Glucose Monitoring System in Euglycemic and Diabetic Swine (Sus scrofa).

Authors:  Rebecca A Ober; Gail E Geist
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-04-13       Impact factor: 1.232