Optical performance of toric intraocular lenses in the presence of decentration.

Bin Zhang1, Jin-Xue Ma1, Dan-Yan Liu1, Ying-Hua Du1, Cong-Rong Guo1, Yue-Xian Cui1.   

Abstract

AIM: To evaluate the optical performance of toric intraocular lenses (IOLs) after decentration and with different pupil diameters, but with the IOL astigmatic axis aligned.
METHODS: Optical performances of toric T5 and SN60AT spherical IOLs after decentration were tested on a theoretical pseudophakic model eye based on the Hwey-Lan Liou schematic eye using the Zemax ray-tracing program. Changes in optical performance were analyzed in model eyes with 3-mm, 4-mm, and 5-mm pupil diameters and decentered from 0.25 mm to 0.75 mm with an interval of 5° at the meridian direction from 0° to 90°. The ratio of the modulation transfer function (MTF) between a decentered and a centered IOL (MTFDecentration/MTFCentration) was calculated to analyze the decrease in optical performance.
RESULTS: Optical performance of the toric IOL remained unchanged when IOLs were decentered in any meridian direction. The MTFs of the two IOLs decreased, whereas optical performance remained equivalent after decentration. The MTFDecentration/MTFCentration ratios of the IOLs at a decentration from 0.25 mm to 0.75 mm were comparable in the toric and SN60AT IOLs. After decentration, MTF decreased further, with the MTF of the toric IOL being slightly lower than that of the SN60AT IOL. Imaging qualities of the two IOLs decreased when the pupil diameter and the degree of decentration increased, but the decrease was similar in the toric and spherical IOLs.
CONCLUSIONS: Toric IOLs were comparable to spherical IOLs in terms of tolerance to decentration at the correct axial position.

Keywords:  artificial; astigmatism; cornea; decentration; lens; model

Year:  2015        PMID: 26309871      PMCID: PMC4539640          DOI: 10.3980/j.issn.2222-3959.2015.04.16

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  37 in total

1.  Age-related changes of defocus-specific contrast sensitivity in healthy subjects.

Authors:  Y K Nio; N M Jansonius; V Fidler; E Geraghty; S Norrby; A C Kooijman
Journal:  Ophthalmic Physiol Opt       Date:  2000-07       Impact factor: 3.117

2.  Modulation transfer function of a toric intraocular lens: evaluation of the changes produced by rotation and tilt.

Authors:  Adelina Felipe; José M Artigas; Amparo Díez-Ajenjo; Carmen García-Domene; Cristina Peris
Journal:  J Refract Surg       Date:  2012-03-26       Impact factor: 3.573

3.  Adaptive optics simulation of intraocular lenses with modified spherical aberration.

Authors:  Patricia A Piers; Enrique J Fernandez; Silvestre Manzanera; Sverker Norrby; Pablo Artal
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-12       Impact factor: 4.799

4.  Optical quality differences between three multifocal intraocular lenses: bifocal low add, bifocal moderate add, and trifocal.

Authors:  David Madrid-Costa; Javier Ruiz-Alcocer; Teresa Ferrer-Blasco; Santiago García-Lázaro; Robert Montés-Micó
Journal:  J Refract Surg       Date:  2013-11       Impact factor: 3.573

Review 5.  Intraocular lens tilt and decentration: a concern for contemporary IOL designs.

Authors:  J B Ale
Journal:  Nepal J Ophthalmol       Date:  2011 Jan-Jun

6.  In-the-bag decentration of a hydrophilic radially asymmetric multifocal intraocular lens secondary to capsule contraction.

Authors:  Jan Willem van der Linden; Ivanka J van der Meulen; Maarten P Mourits; Ruth Lapid-Gortzak
Journal:  J Cataract Refract Surg       Date:  2013-04       Impact factor: 3.351

7.  Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slitlamp observation.

Authors:  Paul J Carey; Antonio Leccisotti; Victoria E McGilligan; Ed A Goodall; C B Tara Moore
Journal:  J Cataract Refract Surg       Date:  2010-02       Impact factor: 3.351

8.  Acrylic toric intraocular lens implantation: a single center experience concerning clinical outcomes and postoperative rotation.

Authors:  Ioannis T Tsinopoulos; Konstantinos T Tsaousis; Dimitrios Tsakpinis; Nikolaos G Ziakas; Stavros A Dimitrakos
Journal:  Clin Ophthalmol       Date:  2010-03-24

9.  Expected effects of surgically induced astigmatism on AcrySof toric intraocular lens results.

Authors:  Warren Hill
Journal:  J Cataract Refract Surg       Date:  2008-03       Impact factor: 3.351

10.  Relationship of the actual thick intraocular lens optic to the thin lens equivalent.

Authors:  J T Holladay; K J Maverick
Journal:  Am J Ophthalmol       Date:  1998-09       Impact factor: 5.258

View more
  2 in total

1.  Effect of decentration, tilt and rotation on the optical quality of various toric intraocular lens designs: a numerical and experimental study.

Authors:  Jesús Pérez-Gracia; Jorge Ares; Francisco J Ávila; Laura Remón
Journal:  Biomed Opt Express       Date:  2022-03-08       Impact factor: 3.562

Review 2.  Tilt and decentration with various intraocular lenses: A narrative review.

Authors:  Xiao-Yong Chen; Yu-Chen Wang; Tian-Yao Zhao; Zi-Zhen Wang; Wei Wang
Journal:  World J Clin Cases       Date:  2022-04-26       Impact factor: 1.534

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.