Literature DB >> 21505548

Intraocular lens tilt and decentration: a concern for contemporary IOL designs.

J B Ale1.   

Abstract

PURPOSE: To review published studies reporting the posterior chamber intraocular lens tilt and decentration after surgically uneventful implantation. Potential influences of normally occurring misalignment of modern designs of IOL on the optical performances are discussed.
MATERIALS AND METHODS: Published theoretical and clinical studies in relation to primarily implanted posterior chamber intraocular lenses and reports relating to more recent development of intraocular lens technologies were reviewed.
RESULTS: Capsulotomy type and integrity, ocular pathology, fixation position of the haptics are some of the important factors causing the misalignment. On an average, a 2-3 degrees tilt and a 0.2 -0.3 mm decentration are common, and which remain clinically unnoticed for any design of IOL. However, theoretical studies predict deterioration of retinal image quality particularly with customized wavefront correcting IOLs. More than a 10 degrees tilt and above 1 mm decentration are occasionally reported even with modern cataract surgery in about 10 % of pseudophakic population.
CONCLUSIONS: The rate and extent of the complication have lowered substantially concomitant with developments in surgical techniques and IOL designs. While emerging designs of modern IOLs offer improved quality of postoperative vision, optimum performance is vastly influenced by the position of the device in the eye. Therefore, additional precision in alignment of modern designs of IOL may be warranted. © NEPjOPH.

Entities:  

Mesh:

Year:  2011        PMID: 21505548     DOI: 10.3126/nepjoph.v3i1.4281

Source DB:  PubMed          Journal:  Nepal J Ophthalmol        ISSN: 2072-6805


  12 in total

1.  Optical performance of toric intraocular lenses in the presence of decentration.

Authors:  Bin Zhang; Jin-Xue Ma; Dan-Yan Liu; Ying-Hua Du; Cong-Rong Guo; Yue-Xian Cui
Journal:  Int J Ophthalmol       Date:  2015-08-18       Impact factor: 1.779

2.  Visual and optical performance of diffractive multifocal intraocular lenses with different haptic designs: 6 month follow-up.

Authors:  Mengmeng Wang; Christine Carole C Corpuz; Megumi Fujiwara; Minoru Tomita
Journal:  Clin Ophthalmol       Date:  2014-05-14

3.  Standard manual capsulorhexis / Ultrasound phacoemulsification compared to femtosecond laser-assisted capsulorhexis and lens fragmentation in clear cornea small incision cataract surgery.

Authors:  Anastasios John Kanellopoulos; George Asimellis
Journal:  Eye Vis (Lond)       Date:  2016-07-29

4.  The Effect of Anterior Capsule Polishing on Capsular Contraction and Lens Stability in Cataract Patients with High Myopia.

Authors:  Dandan Wang; Xiaoyu Yu; Zhangliang Li; Xixia Ding; Hengli Lian; Jianyang Mao; Yinying Zhao; Yun-E Zhao
Journal:  J Ophthalmol       Date:  2018-10-23       Impact factor: 1.909

5.  Keratoconic eyes with stable corneal tomography could benefit more from custom intraocular lens design than normal eyes.

Authors:  Simon Schröder; Timo Eppig; Weidi Liu; Jens Schrecker; Achim Langenbucher
Journal:  Sci Rep       Date:  2019-03-05       Impact factor: 4.379

6.  Evaluation of the optical performance for aspheric intraocular lenses in relation with tilt and decenter errors.

Authors:  Jesús Pérez-Gracia; Alejandra Varea; Jorge Ares; Juan A Vallés; Laura Remón
Journal:  PLoS One       Date:  2020-05-04       Impact factor: 3.240

7.  Rotational stability of modified toric intraocular lens.

Authors:  Ryoko Osawa; Tetsuro Oshika; Masahiko Sano; Takuma Yuguchi; Tadayoshi Kaiya
Journal:  PLoS One       Date:  2021-03-01       Impact factor: 3.240

8.  The Repeatability Assessment of Three-Dimensional Capsule-Intraocular Lens Complex Measurements by Means of High-Speed Swept-Source Optical Coherence Tomography.

Authors:  Xixia Ding; Qinmei Wang; Pingjun Chang; Jin Li; Giacomo Savini; Jinhai Huang; Shenghai Huang; Yinying Zhao; Na Liao; Lei Lin; Xiaoyu Yu; Yun-e Zhao
Journal:  PLoS One       Date:  2015-11-23       Impact factor: 3.240

9.  Outcomes study between femtosecond laser-assisted cataract surgery and conventional phacoemulsification surgery using an active fluidics system.

Authors:  Wilson Takashi Hida; Patrick Frenzel Tzelikis; César Vilar; Mario Augusto Pereira Dias Chaves; Antônio Francisco Pimenta Motta; Pedro Carlos Carricondo; Bruna Vieira Ventura; Renato Ambrosio; Walton Nosé; Milton Ruiz Alves
Journal:  Clin Ophthalmol       Date:  2017-09-25

Review 10.  Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations.

Authors:  Zahra Ashena; Sundas Maqsood; Syed Naqib Ahmed; Mayank A Nanavaty
Journal:  Vision (Basel)       Date:  2020-09-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.