Literature DB >> 26257277

Clinical and radiological outcomes of unstable proximal humeral fractures treated with a locking plate and fibular strut allograft.

Karnav Panchal1, Jae-Jung Jeong1, Sang-Eun Park2, Weon-Yoo Kim1, Hyung-Ki Min1, Ju-Yeong Kim1, Jong-Hun Ji3.   

Abstract

PURPOSE: To evaluate the clinical and radiological outcomes of unstable proximal humeral fractures (PHFs) treated with a locking plate and fibular strut allograft.
METHODS: This study included 36 patients [7 men, 29 women; mean age, 68 years (range, 22-94 years)] with unstable PHFs with medial column disruption. All patients were treated with open reduction and internal fixation using a locking plate and fibular strut allograft. Post-operative assessment included clinical outcomes, shoulder range of motion, radiographic examination, and any complications. Post-operative radiological assessment including the humerus neck-shaft angle (NSA) and the humeral head height was performed.
RESULTS: At the mean two year follow-up visit, the mean American Shoulder and Elbow Society (ASES) and University of California, Los Angeles (UCLA) scores were 77 and 28, respectively. According to the UCLA rating scale, the result was excellent in six, good in 20, fair in six, and poor in four cases. According to the Paavolainen method, 31 patients had good results with an NSA of 130 ± 10°; three patients showed fair results with an NSA of 100-120°, and two patients experienced a poor result with an NSA of <100°. When calculating the humeral head height, the mean loss of reduction was measured as 1.6 mm (from 10.8 or 9.2 mm). Varus collapse and avascular necrosis of the humeral head was noted in two patients for each condition.
CONCLUSIONS: For unstable proximal humerus fractures, particularly in elderly patients with severe osteoporosis or in younger patients with a four-part fracture, locking plate fixation with a fibular strut allograft provided rigid medial support and showed satisfactory clinical and radiological outcomes.

Entities:  

Keywords:  Fibular strut allograft; Locking plate; Unstable proximal humeral fracture

Mesh:

Year:  2015        PMID: 26257277     DOI: 10.1007/s00264-015-2950-0

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  28 in total

1.  Biomechanical analysis of proximal humeral fixation using locking plate fixation with an intramedullary fibular allograft.

Authors:  Craig Mathison; Rey Chaudhary; Lauren Beaupre; Mathew Reynolds; Samer Adeeb; Martin Bouliane
Journal:  Clin Biomech (Bristol, Avon)       Date:  2010-05-16       Impact factor: 2.063

2.  Fixation of proximal humerus fractures using the PHILOS plate: early experience.

Authors:  Athanasios Koukakis; Constantinos D Apostolou; Tarun Taneja; Dimitrios S Korres; Alexander Amini
Journal:  Clin Orthop Relat Res       Date:  2006-01       Impact factor: 4.176

3.  Displaced proximal humeral fractures: part I. Classification and evaluation. 1970.

Authors:  Charles S Neer
Journal:  Clin Orthop Relat Res       Date:  2006-01       Impact factor: 4.176

4.  Use of locking plates in the treatment of proximal humerus fractures.

Authors:  Eric T Ricchetti; William J Warrender; Joseph A Abboud
Journal:  J Shoulder Elbow Surg       Date:  2010-03       Impact factor: 3.019

5.  Predictive factors for functional outcome and failure in angular stable osteosynthesis of the proximal humerus.

Authors:  Francois Hardeman; Peter Bollars; Michaël Donnelly; Johan Bellemans; Stefaan Nijs
Journal:  Injury       Date:  2011-05-12       Impact factor: 2.586

6.  Decision making in displaced fractures of the proximal humerus: fracture or surgeon based?

Authors:  Gertraud Gradl; Matthias Knobe; Hans-Christoph Pape; Paul Valentin Neuhaus; David Ring; Thierry Guitton
Journal:  Int Orthop       Date:  2014-12-14       Impact factor: 3.075

7.  The importance of medial support in locked plating of proximal humerus fractures.

Authors:  Michael J Gardner; Yoram Weil; Joseph U Barker; Bryan T Kelly; David L Helfet; Dean G Lorich
Journal:  J Orthop Trauma       Date:  2007-03       Impact factor: 2.512

8.  Operative treatment of severe proximal humeral fractures.

Authors:  P Paavolainen; J M Björkenheim; P Slätis; P Paukku
Journal:  Acta Orthop Scand       Date:  1983-06

9.  Surgical treatment of three and four-part proximal humeral fractures.

Authors:  Brian D Solberg; Charles N Moon; Dennis P Franco; Guy D Paiement
Journal:  J Bone Joint Surg Am       Date:  2009-07       Impact factor: 5.284

10.  Reconstruction of the valgus-impacted humeral head fracture.

Authors:  H Resch; E Beck; I Bayley
Journal:  J Shoulder Elbow Surg       Date:  1995 Mar-Apr       Impact factor: 3.019

View more
  19 in total

1.  Repair of proximal humerus fracture nonunions using a standardized treatment algorithm: a case series.

Authors:  Kurtis D Carlock; Sanjit R Konda; Isabella R Bianco; Joseph D Zuckerman; Kenneth A Egol
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-01-08

2.  The Use of Fibular Allograft in Complex Periarticular Fractures Around the Knee.

Authors:  Ashley E Levack; Naomi Gadinsky; Elizabeth B Gausden; Craig Klinger; David L Helfet; Dean G Lorich
Journal:  Oper Tech Orthop       Date:  2018-07-29

3.  Open reduction and fixation with a locking plate without bone grafting is a reasonable and safe option for treating proximal humerus nonunion.

Authors:  Stefan Quadlbauer; Georg J Hofmann; Martin Leixnering; Rudolf Rosenauer; Thomas Hausner; Jürgen Reichetseder
Journal:  Int Orthop       Date:  2018-02-13       Impact factor: 3.075

4.  Novel Treatment Options for the Surgical Management of Young Femoral Neck Fractures.

Authors:  Ashley E Levack; Elizabeth B Gausden; Aleksey Dvorzhinskiy; Dean G Lorich; David L Helfet
Journal:  J Orthop Trauma       Date:  2019-01       Impact factor: 2.512

5.  Numerical investigation of fracture impaction in proximal humeral fracture fixation with locking plate and intramedullary nail.

Authors:  Yen-Nien Chen; Chih-Wei Chang; Chia-Wei Lin; Chih-Wei Wang; Yao-Te Peng; Chih-Han Chang; Chun-Ting Li
Journal:  Int Orthop       Date:  2017-01-24       Impact factor: 3.075

6.  [Three-dimensional finite element analysis of exo-cortical placement of humeral calcar screw for reconstruction of medial column stability].

Authors:  Bo Li; Shimin Chang; Sunjun Hu; Shouchao Du; Wenfeng Xiong
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-08-15

7.  Postoperative Evaluation of Reduction Loss in Proximal Humeral Fractures: A Comparison of Plain Radiographs and Computed Tomography.

Authors:  Xiao-Yang Jia; Yan-Xi Chen; Min-Fei Qiang; Kun Zhang; Hao-Bo Li; Yu-Chen Jiang; Yi-Jie Zhang
Journal:  Orthop Surg       Date:  2017-05-30       Impact factor: 2.071

Review 8.  Primary screw perforation or subsequent screw cut-out following proximal humerus fracture fixation using locking plates: a review of causative factors and proposed solutions.

Authors:  Tristan E McMillan; Alan J Johnstone
Journal:  Int Orthop       Date:  2017-10-07       Impact factor: 3.075

Review 9.  [Research progress on medial support augmentation of plate osteosynthesis for proximal humeral fractures].

Authors:  Zuhao Chang; Wei Zhang; Peifu Tang; Hua Chen
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-03-15

Review 10.  Biomechanical analysis of plate systems for proximal humerus fractures: a systematic literature review.

Authors:  Ali Jabran; Chris Peach; Lei Ren
Journal:  Biomed Eng Online       Date:  2018-04-27       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.