Literature DB >> 20483189

Biomechanical analysis of proximal humeral fixation using locking plate fixation with an intramedullary fibular allograft.

Craig Mathison1, Rey Chaudhary, Lauren Beaupre, Mathew Reynolds, Samer Adeeb, Martin Bouliane.   

Abstract

BACKGROUND: Loss of locking plate fixation has been reported in proximal humeral fractures, particularly in older patients with poor bone density. In such fractures, the medial support between the humeral head and shaft is occasionally missing, resulting in varus collapse of the construct. A biomechanical study was performed to understand the behaviour of the interface of these fractures fixed with a locking plate fixation with and without augmentation. The augmentation consisted of an intramedullary fibular allograft (bone peg) that has been reported for use in these fractures.
METHODS: Six embalmed pairs of specimens were utilized; each pair of specimens had one humerus repaired with the locking plate fixation, and the other humerus repaired with the plate fixation and bone peg. The constructs were tested in bending to determine the relative movement between the humeral head and the shaft under bending loads, and the failure loads of both constructs. Digital Imaging Correlation was used to determine the relative movement.
FINDINGS: The bone peg increased the failure load of the constructs by 1.72 (SD 0.54) times (P=0.02). The relative movement was measured by comparing the initial stiffness of both constructs. Initial stiffness of the construct was increased 3.84 (SD 1.92) times (P=0.005) with the use of the bone peg.
INTERPRETATION: The intramedullary bone peg significantly decreases the relative movement at the interface. Further studies are needed to accurately determine the effect this reduction has on the healing process, and overall clinical result. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20483189     DOI: 10.1016/j.clinbiomech.2010.04.006

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  21 in total

1.  Periprosthetic supracondylar femoral fractures following knee arthroplasty: a biomechanical comparison of four methods of fixation.

Authors:  Tatu J Mäkinen; Herman S Dhotar; Simcha G Fichman; Matthew J Gunton; Mitchell Woodside; Oleg Safir; David Backstein; Thomas L Willett; Paul R T Kuzyk
Journal:  Int Orthop       Date:  2015-04-16       Impact factor: 3.075

2.  [Innovations and prognoses].

Authors:  C Voigt; H Lill
Journal:  Unfallchirurg       Date:  2011-12       Impact factor: 1.000

3.  Open reduction and fixation with a locking plate without bone grafting is a reasonable and safe option for treating proximal humerus nonunion.

Authors:  Stefan Quadlbauer; Georg J Hofmann; Martin Leixnering; Rudolf Rosenauer; Thomas Hausner; Jürgen Reichetseder
Journal:  Int Orthop       Date:  2018-02-13       Impact factor: 3.075

4.  Endosteal strut augment reduces complications associated with proximal humeral locking plates.

Authors:  Andrew S Neviaser; Carolyn M Hettrich; Brandon S Beamer; Joshua S Dines; Dean G Lorich
Journal:  Clin Orthop Relat Res       Date:  2011-12       Impact factor: 4.176

5.  Effects of fibular strut augmentation for the open reduction and internal fixation of proximal humeral fractures: a systematic review and meta-analysis.

Authors:  Wei Nie; Zhaojun Wang; Fei Gu; Shizhuang Xu; Yang Yue; Anze Shao; Kefu Sun
Journal:  J Orthop Surg Res       Date:  2022-06-21       Impact factor: 2.677

6.  Open reduction internal fixation of proximal humerus fractures.

Authors:  Marschall B Berkes; Milton T M Little; Dean G Lorich
Journal:  Curr Rev Musculoskelet Med       Date:  2013-03

7.  Clinical and radiological outcomes of unstable proximal humeral fractures treated with a locking plate and fibular strut allograft.

Authors:  Karnav Panchal; Jae-Jung Jeong; Sang-Eun Park; Weon-Yoo Kim; Hyung-Ki Min; Ju-Yeong Kim; Jong-Hun Ji
Journal:  Int Orthop       Date:  2015-08-11       Impact factor: 3.075

Review 8.  Primary screw perforation or subsequent screw cut-out following proximal humerus fracture fixation using locking plates: a review of causative factors and proposed solutions.

Authors:  Tristan E McMillan; Alan J Johnstone
Journal:  Int Orthop       Date:  2017-10-07       Impact factor: 3.075

Review 9.  [Research progress in treatment of proximal humeral fracture with fibular allograft and locking plate].

Authors:  Fei Xing; Xin Duan; Ming Liu; Fuguo Huang; Zhou Xiang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-02-15

Review 10.  [Research progress on intra-articular screw penetration in proximal humeral fracture treated with locking plate].

Authors:  Bo Li; Wenfeng Xiong; Shimin Chang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-04-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.