Literature DB >> 26203706

State of the Art: Iterative CT Reconstruction Techniques.

Lucas L Geyer1, U Joseph Schoepf1, Felix G Meinel1, John W Nance1, Gorka Bastarrika1, Jonathon A Leipsic1, Narinder S Paul1, Marco Rengo1, Andrea Laghi1, Carlo N De Cecco1.   

Abstract

Owing to recent advances in computing power, iterative reconstruction (IR) algorithms have become a clinically viable option in computed tomographic (CT) imaging. Substantial evidence is accumulating about the advantages of IR algorithms over established analytical methods, such as filtered back projection. IR improves image quality through cyclic image processing. Although all available solutions share the common mechanism of artifact reduction and/or potential for radiation dose savings, chiefly due to image noise suppression, the magnitude of these effects depends on the specific IR algorithm. In the first section of this contribution, the technical bases of IR are briefly reviewed and the currently available algorithms released by the major CT manufacturers are described. In the second part, the current status of their clinical implementation is surveyed. Regardless of the applied IR algorithm, the available evidence attests to the substantial potential of IR algorithms for overcoming traditional limitations in CT imaging. (©) RSNA, 2015.

Mesh:

Year:  2015        PMID: 26203706     DOI: 10.1148/radiol.2015132766

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  118 in total

1.  Dose reduction in 64-row whole-body CT in multiple trauma: an optimized CT protocol with iterative image reconstruction on a gemstone-based scintillator.

Authors:  Lucas L Geyer; Markus Körner; Andreas Harrieder; Fabian G Mueck; Zsuzsanna Deak; Stefan Wirth; Ulrich Linsenmaier
Journal:  Br J Radiol       Date:  2016-02-08       Impact factor: 3.039

2.  Deep learning-based image restoration algorithm for coronary CT angiography.

Authors:  Fuminari Tatsugami; Toru Higaki; Yuko Nakamura; Zhou Yu; Jian Zhou; Yujie Lu; Chikako Fujioka; Toshiro Kitagawa; Yasuki Kihara; Makoto Iida; Kazuo Awai
Journal:  Eur Radiol       Date:  2019-04-08       Impact factor: 5.315

Review 3.  Contrast-induced nephropathy in CT: incidence, risk factors and strategies for prevention.

Authors:  Shu Min Tao; Julian L Wichmann; U Joseph Schoepf; Stephen R Fuller; Guang Ming Lu; Long Jiang Zhang
Journal:  Eur Radiol       Date:  2015-12-18       Impact factor: 5.315

4.  Low-dose CT perfusion with projection view sharing.

Authors:  Thomas Martin; John Hoffman; Jeff R Alger; Michael McNitt-Gray; Danny Jj Wang
Journal:  Med Phys       Date:  2017-11-17       Impact factor: 4.071

5.  Reducing the dose of CT of the paranasal sinuses: potential of an iterative reconstruction algorithm.

Authors:  Lars-Arne Schaafs; Julian Lenk; Bernd Hamm; Stefan Markus Niehues
Journal:  Dentomaxillofac Radiol       Date:  2016-07-15       Impact factor: 2.419

6.  [Does coronary CT change the cardiologist's clinical practice?].

Authors:  F André; S J Buß; H A Katus
Journal:  Herz       Date:  2016-08       Impact factor: 1.443

7.  Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol.

Authors:  Moritz H Albrecht; John W Nance; U Joseph Schoepf; Brian E Jacobs; Richard R Bayer; Sheldon E Litwin; Michael A Reynolds; Katharina Otani; Stefanie Mangold; Akos Varga-Szemes; Domenico De Santis; Marwen Eid; Georg Apfaltrer; Christian Tesche; Markus Goeller; Thomas J Vogl; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2017-11-27       Impact factor: 5.315

8.  Inpainting-filtering for metal artifact reduction (IMIF-MAR) in computed tomography.

Authors:  Yakdiel Rodríguez-Gallo; Rubén Orozco-Morales; Marlen Pérez-Díaz
Journal:  Phys Eng Sci Med       Date:  2021-03-24

Review 9.  History and future technical innovation in positron emission tomography.

Authors:  Terry Jones; David Townsend
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-31

10.  Quantification of radiation dose reduction by reducing z-axis coverage in 320-detector coronary CT angiography.

Authors:  David J Murphy; Abhishek Keraliya; Nathan Himes; Ayaz Aghayev; Ron Blankstein; Michael L Steigner
Journal:  Br J Radiol       Date:  2017-06-14       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.