Effect of overcuffing on the accuracy of oscillometric blood pressure measurements.

Jennifer Ringrose1, Jack Millay2, Stephanie Ann Babwick3, Molly Neil1, Lee Ann Langkaas3, Raj Padwal4.   

Abstract

Overcuffing (using too large a blood pressure [BP] cuff), is known to artificially lower auscultatory BP measurements; however, its effect on oscillometric readings is unclear. The possibility that overcuffing biases oscillometric readings is currently widely disregarded. We sought to confirm that overcuffing lowers auscultatory readings and to assess its effect on oscillometric measurements. Community-dwelling adults (aged ≥18 years) with arm circumferences within the standard range of 25-32 cm were recruited. Using primarily the International Standards Organization 2009 protocol, we compared the standard Baum adult (25-35 cm) to the large adult (33-47 cm) cuff. The standard cuff was considered the "reference standard." In Phase I, auscultatory measurements were performed by two trained observers. In Phase II, oscillometric measurements were performed. Each phase was analyzed independently using paired t-tests and by generating Bland-Altman plots. Of 108 participants, 87 contributed data for Phase I, 85 for Phase II, and 69 were common to both phases. Phase I mean age was 38.0 ± 18.5 years, mean arm circumference was 28.0 ± 1.9 cm, and 21% had a past hypertension. The Phase I results confirmed that overcuffing reduced auscultatory BP measurements by 3.6 ± 5.1/2.8 ± 4.0 mm Hg (P-values <.0001 for both). For Phase II, mean age was 39.3 ± 18.3 years, mean arm circumference was 28.0 ± 1.9 cm, and 22% had past hypertension. Mean BPs were 112.2 ± 13.1/67.8 ± 7.3 mm Hg for the large cuff and 117.8 ± 13.3/71.2 ± 7.1 mm Hg for the standard cuff (5.5 ± 5.9/3.4 ± 5.2 mm Hg lower with the large cuff; P-values <.0001).Overcuffing leads to a clinically important downward bias in oscillometric measurements. An upper size limits for oscillometric cuffs should be specified.
Copyright © 2015 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Accuracy; auscultation; cuff size; hypertension

Mesh:

Year:  2015        PMID: 26101170     DOI: 10.1016/j.jash.2015.04.007

Source DB:  PubMed          Journal:  J Am Soc Hypertens        ISSN: 1878-7436


  9 in total

1.  History and Justification of a National Blood Pressure Measurement Validated Device Listing.

Authors:  Jordana B Cohen; Raj S Padwal; Michael Gutkin; Beverly B Green; Michael J Bloch; F Wilford Germino; Domenic A Sica; Anthony J Viera; Benjamin M Bluml; William B White; Sandra J Taler; Steven Yarows; Daichi Shimbo; Raymond R Townsend
Journal:  Hypertension       Date:  2019-02       Impact factor: 10.190

2.  Patient-Specific Oscillometric Blood Pressure Measurement: Validation for Accuracy and Repeatability.

Authors:  Jiankun Liu; Hao-Min Cheng; Chen-Huan Chen; Shih-Hsien Sung; Jin-Oh Hahn; Ramakrishna Mukkamala
Journal:  IEEE J Transl Eng Health Med       Date:  2016-12-14       Impact factor: 3.316

3.  Mean mid-arm circumference and blood pressure cuff sizes for US children, adolescents and adults: National Health and Nutrition Examination Survey, 2011-2016.

Authors:  Yechiam Ostchega; Jeffery P Hughes; Tatiana Nwankwo; Guangyu Zhang
Journal:  Blood Press Monit       Date:  2018-12       Impact factor: 1.444

4.  A Call to Regulate Manufacture and Marketing of Blood Pressure Devices and Cuffs: A Position Statement From the World Hypertension League, International Society of Hypertension and Supporting Hypertension Organizations.

Authors:  Norm R C Campbell; Mark Gelfer; George S Stergiou; Bruce S Alpert; Martin G Myers; Michael K Rakotz; Raj Padwal; Aletta Elisabeth Schutte; Eoin O'Brien; Daniel T Lackland; Mark L Niebylski; Peter M Nilsson; Kimbree A Redburn; Xin-Hua Zhang; Louise Burrell; Masatsugu Horiuchi; Neil R Poulter; Dorairaj Prabhakaran; Agustin J Ramirez; Ernesto L Schiffrin; Rhian M Touyz; Ji-Guang Wang; Michael A Weber
Journal:  J Clin Hypertens (Greenwich)       Date:  2016-02-08       Impact factor: 3.738

5.  The elegance of simplicity.

Authors:  Jennifer Ringrose; Sangita Sridar
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-06-07       Impact factor: 3.738

6.  Validation of the RisingSun RS-651 Blood Pressure Monitor Based on Auscultation in Adults According to the ANSI/AAMI/ISO 81060-2:2013 Standard.

Authors:  Jin She; Xizhou Guan; Yanyong Liu; Haiyan Xiang
Journal:  J Clin Hypertens (Greenwich)       Date:  2016-06-07       Impact factor: 3.738

7.  Systolic peak foot-to-apex time interval, a novel oscillometric technique for systolic blood pressure measurement.

Authors:  Amir M Benmira; Antonia Perez-Martin; Sarah Coudray; Iris Schuster; Isabelle Aichoun; Jérémy Laurent; Fethi Bereski-Reguig; Michel Dauzat
Journal:  J Hypertens       Date:  2017-05       Impact factor: 4.844

8.  Validation of the Omron HEM-1040 Blood Pressure Monitor According to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2:2013 Protocol.

Authors:  Hakuo Takahashi; Kanako Saito
Journal:  Vasc Health Risk Manag       Date:  2020-12-29

9.  The Effect of Cuff Size on Blood Pressure Measurement in Obese Surgical Patients: A Prospective Crossover Clinical Trial.

Authors:  Serpil Yüksel; Gülay Altun-Uğraş; Nurhan Altınok; Necla Demir
Journal:  Florence Nightingale J Nurs       Date:  2020-07-03
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.