Literature DB >> 27913342

Efficient Strategies for Estimating the Spatial Coherence of Backscatter.

Dongwoon Hyun, Anna Lisa C Crowley, Jeremy J Dahl.   

Abstract

The spatial coherence of ultrasound backscatter has been proposed to reduce clutter in medical imaging, to measure the anisotropy of the scattering source, and to improve the detection of blood flow. These techniques rely on correlation estimates that are obtained using computationally expensive strategies. In this paper, we assess the existing spatial coherence estimation methods and propose three computationally efficient modifications: a reduced kernel, a downsampled receive aperture, and the use of an ensemble correlation coefficient. The proposed methods are implemented in simulation and in vivo studies. Reducing the kernel to a single sample improved computational throughput and improved axial resolution. Downsampling the receive aperture was found to have negligible effect on estimator variance, and improved computational throughput by an order of magnitude for a downsample factor of 4. The ensemble correlation estimator demonstrated lower variance than the currently used average correlation. Combining the three methods, the throughput was improved 105-fold in simulation with a downsample factor of 4- and 20-fold in vivo with a downsample factor of 2.

Entities:  

Mesh:

Year:  2016        PMID: 27913342      PMCID: PMC5453518          DOI: 10.1109/TUFFC.2016.2634004

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  25 in total

1.  Adaptive imaging using the generalized coherence factor.

Authors:  Pai-Chi Li; Meng-Lin Li
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-02       Impact factor: 2.725

2.  Transform-Based Channel-Data Compression to Improve the Performance of a Real-Time GPU-Based Software Beamformer.

Authors:  U-Wai Lok; Pai-Chi Li
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-01-19       Impact factor: 2.725

3.  Implementing capon beamforming on a GPU for real-time cardiac ultrasound imaging.

Authors:  Jon Petter Åsen; Jo Inge Buskenes; Carl-Inge Colombo Nilsen; Andreas Austeng; Sverre Holm
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-01       Impact factor: 2.725

4.  GPU-based beamformer: fast realization of plane wave compounding and synthetic aperture imaging.

Authors:  Billy Y S Yiu; Ivan K H Tsang; Alfred C H Yu
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-08       Impact factor: 2.725

5.  Speckle coherence and implications for adaptive imaging.

Authors:  W F Walker; G E Trahey
Journal:  J Acoust Soc Am       Date:  1997-04       Impact factor: 1.840

6.  Effect of subaperture beamforming on phase coherence imaging.

Authors:  Hideyuki Hasegawa; Hiroshi Kanai
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-11       Impact factor: 2.725

7.  Coherent flow power Doppler (CFPD): flow detection using spatial coherence beamforming.

Authors:  You Leo Li; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-06       Impact factor: 2.725

8.  Phase aberration measurements in medical ultrasound: human studies.

Authors:  M O'Donnell; S W Flax
Journal:  Ultrason Imaging       Date:  1988-01       Impact factor: 1.578

9.  Ultrasound speckle size and lesion signal to noise ratio: verification of theory.

Authors:  S W Smith; R F Wagner
Journal:  Ultrason Imaging       Date:  1984-04       Impact factor: 1.578

10.  Sources of image degradation in fundamental and harmonic ultrasound imaging: a nonlinear, full-wave, simulation study.

Authors:  Gianmarco F Pinton; Gregg E Trahey; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-06       Impact factor: 2.725

View more
  20 in total

1.  Robust Short-Lag Spatial Coherence Imaging of Breast Ultrasound Data: Initial Clinical Results.

Authors:  Alycen Wiacek; Ole Marius Hoel Rindal; Eniola Falomo; Kelly Myers; Kelly Fabrega-Foster; Susan Harvey; Muyinatu A Lediju Bell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-11-27       Impact factor: 2.725

2.  Extending Retrospective Encoding for Robust Recovery of the Multistatic Data Set.

Authors:  Rehman Ali; Carl D Herickhoff; Dongwoon Hyun; Jeremy J Dahl; Nick Bottenus
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-12-23       Impact factor: 2.725

3.  Improved Sensitivity in Ultrasound Molecular Imaging With Coherence-Based Beamforming.

Authors:  Dongwoon Hyun; Lotfi Abou-Elkacem; Valerie A Perez; Sayan Mullick Chowdhury; Juergen K Willmann; Jeremy J Dahl
Journal:  IEEE Trans Med Imaging       Date:  2018-01       Impact factor: 10.048

4.  Short-lag Spatial Coherence Imaging in 1.5-D and 1.75-D Arrays: Elevation Performance and Array Design Considerations.

Authors:  Matthew R Morgan; Dongwoon Hyun; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-03-20       Impact factor: 2.725

5.  Reverberation Clutter Suppression Using 2-D Spatial Coherence Analysis.

Authors:  Rifat Ahmed; Nick Bottenus; James Long; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-12-31       Impact factor: 2.725

6.  Clinical Utility of Fetal Short-Lag Spatial Coherence Imaging.

Authors:  Will Long; Dongwoon Hyun; Kingshuk Roy Choudhury; David Bradway; Patricia McNally; Brita Boyd; Sarah Ellestad; Gregg E Trahey
Journal:  Ultrasound Med Biol       Date:  2018-01-11       Impact factor: 2.998

7.  Incoherent Clutter Suppression Using Lag-One Coherence.

Authors:  Will Long; Nick Bottenus; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-02-28       Impact factor: 2.725

8.  Reverberation Noise Suppression in Ultrasound Channel Signals Using a 3D Fully Convolutional Neural Network.

Authors:  Leandra L Brickson; Dongwoon Hyun; Marko Jakovljevic; Jeremy J Dahl
Journal:  IEEE Trans Med Imaging       Date:  2021-04-01       Impact factor: 10.048

9.  Frequency-Dependent Spatial Coherence in Conventional and Chirp Transmissions.

Authors:  James Long; Nick Bottenus; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-04-26       Impact factor: 2.725

10.  Blood Flow Imaging in the Neonatal Brain Using Angular Coherence Power Doppler.

Authors:  Marko Jakovljevic; Byung Chul Yoon; Lotfi Abou-Elkacem; Dongwoon Hyun; You Li; Erika Rubesova; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-12-23       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.