Literature DB >> 26055170

Repeatability of Cerebral Perfusion Using Dynamic Susceptibility Contrast MRI in Glioblastoma Patients.

Kourosh Jafari-Khouzani1, Kyrre E Emblem2, Jayashree Kalpathy-Cramer3, Atle Bjørnerud4, Mark G Vangel3, Elizabeth R Gerstner5, Kathleen M Schmainda6, Kamran Paynabar7, Ona Wu3, Patrick Y Wen8, Tracy Batchelor5, Bruce Rosen3, Steven M Stufflebeam3.   

Abstract

OBJECTIVES: This study evaluates the repeatability of brain perfusion using dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) with a variety of post-processing methods.
METHODS: Thirty-two patients with newly diagnosed glioblastoma were recruited. On a 3-T MRI using a dual-echo, gradient-echo spin-echo DSC-MRI protocol, the patients were scanned twice 1 to 5 days apart. Perfusion maps including cerebral blood volume (CBV) and cerebral blood flow (CBF) were generated using two contrast agent leakage correction methods, along with testing normalization to reference tissue, and application of arterial input function (AIF). Repeatability of CBV and CBF within tumor regions and healthy tissues, identified by structural images, was assessed with intra-class correlation coefficients (ICCs) and repeatability coefficients (RCs). Coefficients of variation (CVs) were reported for selected methods.
RESULTS: CBV and CBF were highly repeatable within tumor with ICC values up to 0.97. However, both CBV and CBF showed lower ICCs for healthy cortical tissues (up to 0.83), healthy gray matter (up to 0.95), and healthy white matter (WM; up to 0.93). The values of CV ranged from 6% to 10% in tumor and 3% to 11% in healthy tissues. The values of RC relative to the mean value of measurement within healthy WM ranged from 22% to 42% in tumor and 7% to 43% in healthy tissues. These percentages show how much variation in perfusion parameter, relative to that in healthy WM, we expect to observe to consider it statistically significant. We also found that normalization improved repeatability, but AIF deconvolution did not.
CONCLUSIONS: DSC-MRI is highly repeatable in high-grade glioma patients.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Year:  2015        PMID: 26055170      PMCID: PMC4486737          DOI: 10.1016/j.tranon.2015.03.002

Source DB:  PubMed          Journal:  Transl Oncol        ISSN: 1936-5233            Impact factor:   4.243


Introduction

Magnetic resonance imaging (MRI) has been used to quantify blood perfusion of the brain for nearly a quarter of a century [1,2]. Cerebral blood volume (CBV) and cerebral blood flow (CBF) have been recognized as biomarkers in a number of neurological diseases, in particular brain tumors [3]. In antiangiogenic therapy of brain tumors, and gliomas in particular, CBV and CBF correlate with tumor grade and response to therapy [4-7]. Changes in blood perfusion are correlated with disease-free survival, best shown with a longitudinal analysis of dynamic susceptibility contrast MRI (DSC-MRI) [8,9]. Monitoring the therapeutic response of anti-vasogenic drugs has increased the interest of DSC-MRI for brain tumors [5-9]. Some studies have shown that DSC-MRI is an imaging biomarker for cerebral perfusion, making it useful for evaluating novel anti-vasogenic agents [7,9]. More recently, dual gradient-echo (GE), spin-echo (SE) DSC-MRI pulse sequences quantify vessel caliber and distinguish low-oxygenation veins from higher oxygenation arteries within the tumor core, which may be predictive of overall survival [10]. One aspect in the evaluation of a biomarker is the reliability and accuracy of the measurements [11]. True changes in the measured perfusion parameters caused by a therapy (regardless of therapy having significant clinical outcome) may be determined by both the measurement error and physiological variations in the tissues. Recently, the Quantitative Imaging Biomarkers Alliance initiative has sought to identify the sources of variation contributing to the measurement error and to improve repeatability and reproducibility of such quantitative imaging biomarkers. This is important to translate imaging biomarkers into clinical trials and general practice. In particular, intra-scanner variations contribute to the measurement error and may be evaluated by repeatability analyses. The repeatability of DSC-MRI is affected by both image acquisition and post-processing. Image acquisition includes signal-to-noise ratio, susceptibility artifact, temporal and spatial resolution, length of imaging, motion artifact, signal saturation [12], misregistration due to frequency shifts induced by contrast agent (CA) [13], and the degree of T1 contamination [14]. Post-processing includes the applicability of the applied kinetic model, accuracy in arterial input function (AIF) detection and deconvolution, accuracy of geometric mapping of selected anatomic regions of interest (ROIs) to the perfusion maps, and the chosen calibration and normalization techniques. Earlier studies have evaluated the optimal DSC image acquisition and post-processing approaches [14-16,2]. Several studies have also evaluated the repeatability of DSC quantification using repeated scans [17-22]. However, most repeatability studies of brain DSC-MRI have been performed for healthy subjects. Only one repeatability study evaluated DSC in gliomas but had a small cohort of patients [17]. Here, we evaluate the repeatability of dual GE and SE DSC-based perfusion on a 3-T MRI scanner using a double baseline MRI acquisition setup in 32 patients with newly diagnosed glioblastoma. We compare CBV and CBF from two MRI exams taken within 1 to 5 days in both healthy tissue and tumor using two of the state-of-the-art leakage correction methods and an automated AIF detection algorithm. By assessing the repeatability of DSC-MRI, we quantify the variations in these measurements caused by the intra-scanner and normal biologic variations using current methodologies, with the goal of defining true changes of perfusion in human brain tumors. This will strengthen its use as an imaging biomarker. We hope this study will contribute to the understanding the sources of measurement variability in DSC-MRI.

Materials and Methods

Patients

The Institutional Review Board approved this study. Informed consent was obtained from all patients. We recruited 40 adult patients with newly diagnosed grade IV glioblastomas in a study of cediranib, a small molecule pan–vascular endothelial growth factor tyrosine kinase inhibitor, sponsored by the National Cancer Institute (R01CA129371) [23-25]. Of 40 patients, eight were eliminated because of missing a scan (n = 4) or inadequate image quality (n = 4). The remaining 32 patients (19 M, 13 F, age 23-75, mean 56) were included in the study. All patients were on a stable or decreasing dose of steroids for 5 days before each scan. The patients did not receive cediranib before or between the two scans. No tumor had significant progression between the two scans as measured by change in contrast enhancing tumor (ET) volume or fluid-attenuated inversion recovery (FLAIR) hyperintensity (FH). Most tumors were unifocal and some were midline, but these factors should not influence the results of our analysis as we compared the DSC results within patients.

Magnetic Resonance Imaging

Each subject was scanned at two time points (hereafter referred to as baselines 1 and 2) using an identical imaging protocol on a 3.0-T MRI System (TimTrio; Siemens Medical Solutions, Malvern, PA). The scans were done 1 to 5 days apart (mean ± SD = 3.7 ± 1.4) to allow the contrast to wash out between scans. AutoAlign was used to ensure that the brain was oriented the same way for every scan. DSC-MRI was acquired as follows: a 78-mm slab of tissue was imaged using a dual-echo, combined GE and SE echo planar imaging sequence, with echo times of 31 and 94 milliseconds, respectively, a repetition time of 1.48 seconds, a flip angle of 90°, and 1.2-mm in-plane (160 × 160 matrix) and 6.5-mm through-plane resolution. A total of 100 volumes were acquired and 0.1 mmol/kg Gd-DTPA (Magnivist) was injected at 5 ml/s after approximately 81 seconds of imaging. The DSC acquisition was preceded by a dynamic contrast-enhanced acquisition (0.1 mmol/kg Gd-DTPA injected at 5 ml/s), and this CA injection acted as a pre-dose to minimize errors in CBV estimates due to T1-shortening effects induced by CA extravasation in regions of blood-brain barrier breakdown or resection. In addition, structural images including axial FLAIR with 0.43 mm × 0.43 mm × 6 mm resolution, post-contrast T1-weighted image with 0.43 mm × 0.43 mm × 6 mm resolution, and magnetization-prepared rapid GE (MPRAGE) with 1-mm isotropic voxels were acquired.

Perfusion Analysis

Before perfusion analysis, potential motion artifacts (motion between time points) in the DSC data were detected and corrected using FSL (http://www.fmrib.ox.ac.uk/fsl/). Figure 1 shows the analysis methods that were used in the experiments. All perfusion analyses as described in the Supplementary Materials were performed in a modified version of nordicICE (NordicNeuroLab AS, Bergen, Norway).
Figure 1

Flowchart summarizing the analysis steps for the different methods used for generation of hemodynamic images and consequent ROI analysis. The bottom row from left to right shows FH ROI, ET ROI, healthy cortical tissues, and healthy WM and GM ROIs, respectively.

Kinetic modeling

Two established kinetic models for CA extravasation correction were compared: Method 1 is based on the correction technique proposed by Weisskoff et al. [26] and later elaborated by Donahue et al. [27] and Boxerman et al. [28]. Method 2 is based on the estimation of CA extravasation from the tissue residue function [29]. AIF deconvolution is by default applied in method 2, but it is an option for method 1.

AIF determination and normalization

The AIFs were determined automatically in each patient by an established clustering method [30] that has been shown to have a good agreement with manual AIF selection and provide physiologically plausible perfusion estimates without user interaction [31]. Normalization to a reference tissue mask improves the reliability of CBV and CBF measurements [32,33]. Reference tissue masks representing unaffected gray matter (GM) and white matter (WM) were generated automatically from the DSC images as previously described [34,31]. A combined WM + GM mask was used to generate the reference tissue response curves used for CA extravasation correction according to method 1 and also to generate normalized CBV and CBF maps by dividing the respective perfusion parameters by their corresponding mean value in the WM + GM mask. The CBV and CBF maps were calculated both with and without applying AIF deconvolution (for method 1, the residue function is corrected directly for leakage effects and CBV is then estimated from the corrected residue function rather than from the normal raw data integral ratio) and with and without normalization to the WM + GM mask for both GE and SE images (Figure 1).

Image Analysis

For each subject, tumor and healthy tissue ROIs were generated as described below for baseline 1 and mapped to baseline 2 by rigid coregistration to ensure that the same regions were evaluated in both baselines and to eliminate the inter-rater variations of ROI drawing. ET was outlined on 3-dimensional (3D) post-contrast T1-weighted axial images by an experienced neuroradiologist with 5 years of clinical experience in brain tumor imaging [35]. Likewise, FH was outlined on 3D FLAIR images. Several cortical regions were also automatically segmented by non-rigid registration of the Harvard-Oxford Atlas to the MPRAGE images using ANTS [36]. Regions contralateral to the tumor were considered “healthy” brain (see Figures 1, S1, and S2). MPRAGE volumes were also segmented into healthy WM and GM using FSL to create a separate label volume for the healthy (or healthier) hemisphere (distinct from the WM + GM reference mask automatically generated from DSC-MRI) [37]. Sample ROIs are shown in Figure 1. Finally, all labels were mapped to the perfusion maps by rigid coregistration in SPM (http://www.fil.ion.ucl.ac.uk/spm/). The mean values of the generated perfusion maps were calculated within each ROI.

Statistical Analysis

Intra-class correlation coefficients (ICCs) and repeatability coefficients (RCs) were computed in MATLAB (The Mathworks, Natick, MA) for the tumor and healthy tissue ROIs. ICC was calculated using a two-way random effect model [38]. ICC ranges from 0 to 1 and describes how strongly two within-subject measurements resemble each other relative to the variation between subjects. RC represents the estimated range of variation between the measurements so that the difference between two measurements is expected to be between − RC and RC for 95% of patients. RC was calculated as where is equal to the standard deviation of the measurement differences. RC reflects how much change should occur to be considered significant [39]. For healthy tissues segmented by atlas-based segmentation, averages of ICCs and RCs were reported. We also calculated the ratio of RC to the mean value of the measurement within healthy WM for selected methods. Assuming that the mean values of perfusion parameters in healthy WM are similar among patients, these values reported in percentage show how much variation, due to both measurement error and physiological variations, we may expect relative to the mean value within healthy WM. This measure is more informative than a measure such as within-subject coefficient of variation (CV, defined as σW/μ, where μ is mean value), which depends on the mean value of all measurements and thus varies with the tissue type and patient population. However, we also reported CV for select methods. To compare the ICC of two methods, a bootstrapping approach with 5000 repetitions to generate samples was used for hypothesis testing [40]. In each repetition of the bootstrap procedure, we randomly resampled the available data with replacement such that the size of each subsample is the same as the size of the original data. Then, the ICC means of both methods were calculated from the generated bootstrapped samples and compared through a mean hypothesis testing procedure [41]. Using the false discovery rate control [42], the significance level of each hypothesis test was corrected for multiple comparisons with an overall significance level of 0.05.

Results

Very high repeatability was obtained for all perfusion metrics, with ICC values > 0.9 in tumor for both GE CBV and CBF after normalization. A comprehensive table of the ICCs and RCs is provided in the Supplementary Materials (Tables S1–S2). Overall, both methods had excellent ICCs after normalization. Method 1 had slightly higher ICCs. Using this method, the GE CBV maps had very high ICC within ET (ICC = 0.96) and FH (ICC = 0.97). The same was true for CBF (ICC = 0.97 for ET and ICC = 0.96 for FH). Table 1 compares the ICCs, RCs, and CVs before and after normalization using method 1 with AIF deconvolution. Normalization always improved the ICCs of both GE and SE maps (P < .05 is highlighted). False discovery rates are highlighted in darker gray (corresponding to P < .0032). After normalization, WM and GM had a lower RC compared with tumor regions, indicating that their intra-subject variability was lower compared with tumor regions. Furthermore, normalization always decreased CV. For GE CBV, GE CBF, SE CBV, and SE CBF, the CV values after normalization ranged from 8.8% to 10.0% for ET, 6.4% to 10.4% for FH, 3.1% to 6.2% for GM, and 2.6% to 4.8% for WM. However, since CV is dependent on the mean value of measurements and there is variability in tumor perfusion, we have also reported the ratios (percentages) of RCs to the mean value of measurements within healthy WM of all subjects in Table 1. As shown, normalization often reduced the variance resulting in more stable measurements. Note that the high percentages of variations for tumor regions are partly due to higher perfusion in these regions compared to the healthy WM.
Table 1

Comparison of ICCs, RCs, CVs, and Ratios (Percentages) of RC and Mean Value of Measurement within Healthy WM before and after Normalization. The values Were Generated Using Method 1 with AIF Deconvolution. Comparisons for ICCs with P < .05 Are Highlighted in Gray. Statistically Significant Comparisons Are Highlighted in Dark Gray. Higher ICCs and Lower CV and RC Percentages Are in Boldface

Tables 2 and 3 evaluate the effect of AIF deconvolution. Using method 1 and when normalization was not applied, the application of AIF deconvolution on average decreased the ICCs for GE sequence with some P values under .05 (Table 2). This comparison was statistically significant for SE CBF of WM. Using method 1 and when normalization was applied, the application of AIF deconvolution on average did not significantly change the ICCs (Table 3). In method 2, AIF deconvolution is applied by default. When compared with method 1 with AIF deconvolution, method 2 often trended toward lower ICCs for GE sequence (Table 4), with some P values under .05 but not statistically significant by false discovery rate control.
Table 2

Comparison of ICCs before and after AIF Deconvolution. The ICCs Were Generated Using Method 1 without Normalization. Comparisons with P < .05 Are Highlighted in Gray. Statistically Significant Comparisons Are Highlighted in Dark Gray

Table 3

Comparison of ICCs before and after AIF Deconvolution. The ICCs Were Generated Using Method 1 with Normalization. The Differences between ICCs Were Not Statistically Significant

GE
SE
CBV
CBF
CBV
CBF
ROIBeforeAfterBeforeAfterBeforeAfterBeforeAfter
Enhancing Tumor0.960.960.960.970.960.960.950.94
FLAIR Hyperintensity0.970.970.950.960.920.920.930.88
Gray Matter0.950.950.930.940.870.870.870.87
White Matter0.900.890.880.930.760.750.760.65
Cortical Tissues (Mean±SD)0.82 ± 0.110.82 ± 0.110.83 ± 0.100.81 ± 0.120.71 ± 0.140.70 ± 0.140.74 ± 0.090.72 ± 0.13
Table 4

Comparison of ICCs for Methods 1 and 2. The ICCs Were Generated with AIF Deconvolution and Normalization. Comparisons with P < .05 Are Highlighted in Gray

On average, ICC of both CBV and CBF within the FH region was comparable to the ICC of the ET after normalization. For WM and GM and healthy cortical tissues, both ICCs and RCs were generally lower than those of the tumor regions. In particular, CBV and CBF, respectively, had maximum ICCs of 0.95 and 0.94 in GM, 0.90 and 0.93 in WM, and 0.82 ± 0.11 and 0.83 ± 0.10 in cortical regions. The Bland-Altman plots of the GE parametric maps of tumor, WM, and GM regions demonstrate that both inter-subject variability and intra-subject variability were lower in healthy WM and GM compared with tumor regions (Figures 2 and 3). Furthermore, inter-subject variability was lower within the FH compared with ET. Intra-subject variability was also slightly lower (Table 1). The mean ± SD values of GE CBV generated by method 1 with AIF deconvolution and normalization were 1.65 ± 0.83 within ET, 1.36 ± 0.48 within FH, 1.63 ± 0.22 within GM, and 1.09 ± 0.09 within WM. For SE CBV, these values were 0.99 ± 0.42, 0.95 ± 0.32, 1.31 ± 0.20, and 0.89 ± 0.09, respectively (see Table S3 for a complete list of mean ± SD values). High ICC values were also obtained for CBV and CBF derived from the SE sequence within ET and FH (ICC ≥ 0.9 after normalization) but still lower compared with the same parameters obtained from the GE data. Using method 1 with normalization for CBV, ICC = 0.96 within ET and ICC = 0.92 within FH (Table 1). For CBF, ICC = 0.94 within ET and ICC = 0.88 within FH. Similar to GE maps, the ICCs were lower within the cortical tissues in comparison with tumor regions. Normalization often improved the ICCs. The effect of AIF deconvolution for method 1 is shown for SE images in Tables 2 and 3. Using method 1 and when normalization was not applied, AIF deconvolution decreased ICC in WM (P < .05). However, when normalization was applied, AIF deconvolution did not significantly change the ICCs (Table 3). Similar to GE sequence, when comparing with method 1 with AIF deconvolution (Table 4), method 2 often trended toward lower ICCs (P < .05 for some SE CBV values, yet not under the threshold of 0.0032 set by false discovery rate control).

Discussion

Targeting blood vessels has become an attractive strategy in cancer therapeutic interventions. The dependence of tumor growth on the recruitment of new blood vessels by angiogenesis has inspired the development of antiangiogenic approaches to cancer therapy. These new agents might perform best in combination with other traditional cytotoxic drugs, indicating that a systematic process of testing and optimization is necessary—a process greatly aided by non-invasive biomarkers. DSC-MRI may indeed provide such a biomarker, notably by measuring changes in perfusion as well as microvessel caliber that accompany response [9,10]. Translation of such biomarkers into clinical trials and practice requires the identification of all sources of variation in the measurement, such as variations related to image acquisition, post-processing, and physiological variations. This is essential in determining the true changes caused by the therapy effect. The goal is to limit the measurement error related to such variations to reliably detect true changes. This study evaluated the measurement error related to within-scanner and physiological variations. This required repeated scans on the same scanner and we referred to it as repeatability and may be evaluated by the ICC and RC values [43,44]. We identified post-processing methods that have smaller contribution to the measurement error and showed that the resultant measurement error is small relative to inter-subject variation, resulting in improved repeatability. The AIF deconvolution had large contributions to the measurement error. This may be due to the variability introduced by AIF detection despite showing good agreement with manual AIF detection in previous studies [30,31]. However, normalization significantly reduced such post-processing variations. AIF deconvolution may be beneficial for the estimation of regional flow variations (delay), CA leakage correction [29], and in MRI-based vessel caliber imaging and also multimodal image comparisons where a pseudo-quantitative CBV value might be relevant [45,46,31]. In this study, the reference tissues were generated automatically. Manual ROI selection would add some user bias, as it is difficult to place the ROIs in exactly the same positions in both sessions. The WM GE CBV was slightly higher than 1 (1.09 ± 0.09), whereas WM SE CBV was slightly lower than 1 (0.89 ± 0.09). Note that the nordicICE WM/GM segmentation algorithm removes macroscopic vessels since the method is based on segmentation from hemodynamic features derived from the voxel-wise time-intensity curves. WM segmentation from structural scans will, however, include vessels leading to an increase in relative WM CBV. As vessels are much more prominent in GE DSC than in SE DSC, they contribute to more elevated CBV values in GE compared to SE. Note that since the ICC is related to the ratio of inter-subject variability to intra-subject variability, it measures the sensitivity of the measurement in distinguishing differences between subjects. Tumor regions had higher ICC values in comparison with healthy tissues despite having larger RC values, mainly due to larger inter-subject variance. To determine what level of change in the perfusion parameter should be observed to be confident that there is a true change in the parameter, the RC may be used [11]. The ability to determine that perfusion remains unchanged is part of the same assessment. We reported the values of RC relative to the mean value within healthy WM. The CV values were under 11%. This is very well in line with the goals of Quantitative Imaging Biomarkers Alliance that aims at reaching CV < 20%. Table 1 reveals that a change in GE CBV of ET greater than 42% relative to the mean value of CBV within WM may be considered significant with a 95% confidence (42% × 1.09/1.65 = 28% compared to the mean value within tumor). CBV RC is 22%, 13%, 7%, and 36% for GE CBV of FH, GM, WM, and healthy cortical tissues, respectively. For other perfusion parameters, relative RC values are reported in Table 1. This study evaluated the repeatability of mean relative CBV (rCBV) and relative CBF. We chose mean value due to the variability of perfusion within the tumors. Other measurements such as maximal rCBV and relative CBF may also be used to evaluate tumor malignancy [47], but mean rCBV is the most commonly reported when measuring tumor response. We did not exclude patients who had prior surgery. Hemorrhage and post-surgery signal dropout had little impact on our measurements since such signal dropout is primarily an issue immediately after the surgery, whereas our patients were weeks/months away from the surgery. In addition, such changes affect both baselines similarly and have little impact on the repeatability analysis. Similarly, tumor hemorrhage and calcification as well as steroid have little effect on the repeatability analysis since they have similar effects on both baseline images. To translate DSC-MRI into general practice, other sources of variations such as between-scanner variations and inter-rater variations for ROI placement need to be evaluated. This requires evaluation of a data set with each patient scanned on different scanners and is referred to as the reproducibility study. We had acquired both images on the same scanner and had eliminated the inter-rater variations by mapping the ROI of visit 1 to visit 2. This allowed us to independently evaluate the within-scanner and physiological variations. We generated the perfusion maps using readily available software. Although this makes the translation of DSC-MRI to clinical practice more feasible, reproducibility across such post-processing software tools will be evaluated in future studies. In conclusion, GE and SE DSC maps are highly repeatable demonstrated by an optimized double baseline protocol. Normalization of the derived perfusion metrics to corresponding values in healthy tissue increases the repeatability of measurements, but AIF deconvolution may decrease it. Therefore, for most clinical scenarios, a normalized CBV or CBF without AIF deconvolution is acceptable and produce repeatable values.
  42 in total

1.  Test-retest reliability of DSC MRI CBV mapping in healthy volunteers.

Authors:  M E Henry; M J Kaufman; N Lange; M E Schmidt; S Purcell; J Cote; D M Perron-Henry; E Stoddard; B M Cohen; P F Renshaw
Journal:  Neuroreport       Date:  2001-06-13       Impact factor: 1.837

2.  Reproducibility and correlation between quantitative and semiquantitative dynamic and intrinsic susceptibility-weighted MRI parameters in the benign and malignant human prostate.

Authors:  Roberto Alonzi; N Jane Taylor; J James Stirling; James A d'Arcy; David J Collins; Michele I Saunders; Peter J Hoskin; Anwar R Padhani
Journal:  J Magn Reson Imaging       Date:  2010-07       Impact factor: 4.813

3.  Method for improving the accuracy of quantitative cerebral perfusion imaging.

Authors:  Ken E Sakaie; Wanyong Shin; Kenneth R Curtin; Richard M McCarthy; Ty A Cashen; Timothy J Carroll
Journal:  J Magn Reson Imaging       Date:  2005-05       Impact factor: 4.813

Review 4.  Quantitative multimodality imaging in cancer research and therapy.

Authors:  Thomas E Yankeelov; Richard G Abramson; C Chad Quarles
Journal:  Nat Rev Clin Oncol       Date:  2014-08-12       Impact factor: 66.675

5.  Standardization of relative cerebral blood volume (rCBV) image maps for ease of both inter- and intrapatient comparisons.

Authors:  Devyani Bedekar; Todd Jensen; Kathleen M Schmainda
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

6.  Utility of simultaneously acquired gradient-echo and spin-echo cerebral blood volume and morphology maps in brain tumor patients.

Authors:  K M Donahue; H G Krouwer; S D Rand; A P Pathak; C S Marszalkowski; S C Censky; R W Prost
Journal:  Magn Reson Med       Date:  2000-06       Impact factor: 4.668

7.  Dynamic-susceptibility contrast agent MRI measures of relative cerebral blood volume predict response to bevacizumab in recurrent high-grade glioma.

Authors:  Kathleen M Schmainda; Melissa Prah; Jennifer Connelly; Scott D Rand; Raymond G Hoffman; Wade Mueller; Mark G Malkin
Journal:  Neuro Oncol       Date:  2014-01-15       Impact factor: 12.300

8.  Glial tumor grading and outcome prediction using dynamic spin-echo MR susceptibility mapping compared with conventional contrast-enhanced MR: confounding effect of elevated rCBV of oligodendrogliomas [corrected].

Authors:  Michael H Lev; Yelda Ozsunar; John W Henson; Amjad A Rasheed; Glenn D Barest; Griffith R Harsh; Markus M Fitzek; E Antonio Chiocca; James D Rabinov; Andrew N Csavoy; Bruce R Rosen; Fred H Hochberg; Pamela W Schaefer; R Gilberto Gonzalez
Journal:  AJNR Am J Neuroradiol       Date:  2004-02       Impact factor: 3.825

9.  Improved tumor oxygenation and survival in glioblastoma patients who show increased blood perfusion after cediranib and chemoradiation.

Authors:  Tracy T Batchelor; Elizabeth R Gerstner; Kyrre E Emblem; Dan G Duda; Jayashree Kalpathy-Cramer; Matija Snuderl; Marek Ancukiewicz; Pavlina Polaskova; Marco C Pinho; Dominique Jennings; Scott R Plotkin; Andrew S Chi; April F Eichler; Jorg Dietrich; Fred H Hochberg; Christine Lu-Emerson; A John Iafrate; S Percy Ivy; Bruce R Rosen; Jay S Loeffler; Patrick Y Wen; A Greg Sorensen; Rakesh K Jain
Journal:  Proc Natl Acad Sci U S A       Date:  2013-11-04       Impact factor: 11.205

10.  Quantitative cerebral perfusion using dynamic susceptibility contrast MRI: evaluation of reproducibility and age- and gender-dependence with fully automatic image postprocessing algorithm.

Authors:  Wanyong Shin; Sandra Horowitz; Ann Ragin; Yufen Chen; Matthew Walker; Timothy J Carroll
Journal:  Magn Reson Med       Date:  2007-12       Impact factor: 4.668

View more
  22 in total

1.  Dynamic susceptibility contrast MRI measures of relative cerebral blood volume continue to show promise as an early response marker in the setting of bevacizumab treatment.

Authors:  Jerrold L Boxerman; Kathleen M Schmainda; Zheng Zhang; Daniel P Barboriak
Journal:  Neuro Oncol       Date:  2015-09-11       Impact factor: 12.300

2.  Multisite Concordance of DSC-MRI Analysis for Brain Tumors: Results of a National Cancer Institute Quantitative Imaging Network Collaborative Project.

Authors:  K M Schmainda; M A Prah; S D Rand; Y Liu; B Logan; M Muzi; S D Rane; X Da; Y-F Yen; J Kalpathy-Cramer; T L Chenevert; B Hoff; B Ross; Y Cao; M P Aryal; B Erickson; P Korfiatis; T Dondlinger; L Bell; L Hu; P E Kinahan; C C Quarles
Journal:  AJNR Am J Neuroradiol       Date:  2018-05-24       Impact factor: 3.825

3.  Analyzing magnetic resonance imaging data from glioma patients using deep learning.

Authors:  Bjoern Menze; Fabian Isensee; Roland Wiest; Bene Wiestler; Klaus Maier-Hein; Mauricio Reyes; Spyridon Bakas
Journal:  Comput Med Imaging Graph       Date:  2020-12-02       Impact factor: 4.790

4.  Repeatability of dynamic contrast enhanced vp parameter in healthy subjects and patients with brain tumors.

Authors:  Moran Artzi; Gilad Liberman; Deborah T Blumenthal; Felix Bokstein; Orna Aizenstein; Dafna Ben Bashat
Journal:  J Neurooncol       Date:  2018-11-03       Impact factor: 4.130

5.  Diffuse microvascular dysfunction and loss of white matter integrity predict poor outcomes in patients with acute ischemic stroke.

Authors:  Natalia S Rost; Pedro Cougo; Svetlana Lorenzano; Hua Li; Lisa Cloonan; Mark Jrj Bouts; Arne Lauer; Mark R Etherton; Hasan H Karadeli; Patricia L Musolino; William A Copen; Ken Arai; Eng H Lo; Steve K Feske; Karen L Furie; Ona Wu
Journal:  J Cereb Blood Flow Metab       Date:  2017-05-08       Impact factor: 6.200

6.  Accelerated whole-brain perfusion imaging using a simultaneous multislice spin-echo and gradient-echo sequence with joint virtual coil reconstruction.

Authors:  Mary Kate Manhard; Berkin Bilgic; Congyu Liao; SoHyun Han; Thomas Witzel; Yi-Fen Yen; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-05-08       Impact factor: 4.668

7.  Pseudo-extravasation rate constant of dynamic susceptibility contrast-MRI determined from pharmacokinetic first principles.

Authors:  Xin Li; Csanad G Varallyay; Seymur Gahramanov; Rongwei Fu; William D Rooney; Edward A Neuwelt
Journal:  NMR Biomed       Date:  2017-09-08       Impact factor: 4.044

8.  Magnetic Resonance Imaging Parameters and Their Impact on Survival of Patients with Glioblastoma: Tumor Perfusion Predicts Survival.

Authors:  Bob L Hou; Sijin Wen; Gennadiy A Katsevman; Hui Liu; Ogaga Urhie; Ryan C Turner; Jeffrey Carpenter; Sanjay Bhatia
Journal:  World Neurosurg       Date:  2018-12-27       Impact factor: 2.104

9.  Standardized acquisition and post-processing of dynamic susceptibility contrast perfusion in patients with brain tumors, cerebrovascular disease and dementia: comparability of post-processing software.

Authors:  Manuel Alexander Schmidt; Michael Knott; Philip Hoelter; Tobias Engelhorn; Elna Marie Larsson; Than Nguyen; Marco Essig; Arnd Doerfler
Journal:  Br J Radiol       Date:  2019-10-24       Impact factor: 3.039

Review 10.  MRI biomarkers in neuro-oncology.

Authors:  Marion Smits
Journal:  Nat Rev Neurol       Date:  2021-06-20       Impact factor: 42.937

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.