Literature DB >> 15834910

Method for improving the accuracy of quantitative cerebral perfusion imaging.

Ken E Sakaie1, Wanyong Shin, Kenneth R Curtin, Richard M McCarthy, Ty A Cashen, Timothy J Carroll.   

Abstract

PURPOSE: To improve the accuracy of dynamic susceptibility contrast (DSC) measurements of cerebral blood flow (CBF) and volume (CBV).
MATERIALS AND METHODS: In eight volunteers, steady-state CBV (CBV(SS)) was measured using TrueFISP readout of inversion recovery (IR) before and after injection of a bolus of contrast. A standard DSC (STD) perfusion measurement was performed by echo-planar imaging (EPI) during passage of the bolus and subsequently used to calculate the CBF (CBF(DSC)) and CBV (CBV(DSC)). The ratio of CBV(SS) to CBV(DSC) was used to calibrate measurements of CBV and CBF on a subject-by-subject basis.
RESULTS: Agreement of values of CBV (1.77 +/- 0.27 mL/100 g in white matter (WM), 3.65 +/- 1.04 mL/100 g in gray matter (GM)), and CBF (23.6 +/- 2.4 mL/(100 g min) in WM, 57.3 +/- 18.2 mL/(100 g min) in GM) with published gold-standard values shows improvement after calibration. An F-test comparison of the coefficients of variation of the CBV and CBF showed a significant reduction, with calibration, of the variability of CBV in WM (P < 0.001) and GM (P < 0.03), and of CBF in WM (P < 0.0001).
CONCLUSION: The addition of a CBV(SS) measurement to an STD measurement of cerebral perfusion improves the accuracy of CBV and CBF measurements. The method may prove useful for assessing patients suffering from acute stroke.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15834910     DOI: 10.1002/jmri.20305

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  25 in total

1.  Correction for arterial-tissue delay and dispersion in absolute quantitative cerebral perfusion DSC MR imaging.

Authors:  Jessy J Mouannes-Srour; Wanyong Shin; Sameer A Ansari; Michael C Hurley; Parmede Vakil; Bernard R Bendok; John L Lee; Colin P Derdeyn; Timothy J Carroll
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

2.  SCALE-PWI: A pulse sequence for absolute quantitative cerebral perfusion imaging.

Authors:  Jessy Mouannes Srour; Wanyong Shin; Saurabh Shah; Anindya Sen; Timothy J Carroll
Journal:  J Cereb Blood Flow Metab       Date:  2010-12-15       Impact factor: 6.200

3.  First results in an MR imaging--compatible canine model of acute stroke.

Authors:  A Shaibani; S Khawar; W Shin; T A Cashen; B Schirf; M Rohany; S Kakodkar; T J Carroll
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

4.  Quantitative cerebral blood flow in dynamic susceptibility contrast MRI using total cerebral flow from phase contrast magnetic resonance angiography.

Authors:  David Bonekamp; Mahaveer Degaonkar; Peter B Barker
Journal:  Magn Reson Med       Date:  2011-02-01       Impact factor: 4.668

5.  Decreased frontal lobe gray matter perfusion in cognitively impaired patients with secondary-progressive multiple sclerosis detected by the bookend technique.

Authors:  R I Aviv; P L Francis; R Tenenbein; P O'Connor; L Zhang; A Eilaghi; L Lee; T J Carroll; J Mouannes-Srour; A Feinstein
Journal:  AJNR Am J Neuroradiol       Date:  2012-04-26       Impact factor: 3.825

6.  Quantification of cerebral perfusion using the "bookend technique": an evaluation in CNS tumors.

Authors:  Timothy J Carroll; Sandra Horowitz; Wanyong Shin; Jessy Mouannes; Rahul Sawlani; Saad Ali; Jeffrey Raizer; Stephen Futterer
Journal:  Magn Reson Imaging       Date:  2008-06-05       Impact factor: 2.546

7.  Increased atherogenic lipoproteins are associated with cognitive impairment: effects of statins and subclinical atherosclerosis.

Authors:  Cynthia M Carlsson; David M Nondahl; Barbara E K Klein; Patrick E McBride; Mark A Sager; Carla R Schubert; Ronald Klein; Karen J Cruickshanks
Journal:  Alzheimer Dis Assoc Disord       Date:  2009 Jan-Mar       Impact factor: 2.703

Review 8.  Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities.

Authors:  Linda Knutsson; Freddy Ståhlberg; Ronnie Wirestam
Journal:  MAGMA       Date:  2009-12-04       Impact factor: 2.310

9.  Prognostic value of blood flow estimated by arterial spin labeling and dynamic susceptibility contrast-enhanced MR imaging in high-grade gliomas.

Authors:  Mandy Kim Rau; Christian Braun; Marco Skardelly; Jens Schittenhelm; Frank Paulsen; Benjamin Bender; Ulrike Ernemann; Sotirios Bisdas
Journal:  J Neurooncol       Date:  2014-08-27       Impact factor: 4.130

10.  A comparison of individual and population-derived vascular input functions for quantitative DCE-MRI in rats.

Authors:  David A Hormuth; Jack T Skinner; Mark D Does; Thomas E Yankeelov
Journal:  Magn Reson Imaging       Date:  2014-01-07       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.