Literature DB >> 25999412

Long-Term Follow-Up Results following Elective Treatment of Unruptured Intracranial Aneurysms with the Pipeline Embolization Device.

A H Y Chiu1, A K Cheung2, J D Wenderoth3, L De Villiers4, H Rice4, C C Phatouros5, T P Singh5, T J Phillips5, W McAuliffe5.   

Abstract

BACKGROUND AND
PURPOSE: Numerous reports of treatment of wide-neck aneurysms by flow diverters have been published; however, long-term outcomes remain uncertain. This article reports the imaging results of unruptured aneurysms treated electively with the Pipeline Embolization Device for up to 56 months and clinical results for up to 61 months.
MATERIALS AND METHODS: One hundred nineteen aneurysms in 98 patients from 3 centers admitted between August 2009 and June 2011 were followed at 6-month, 1-year, and 2+-year postprocedural timeframes. Analyses on the effects of incorporated vessels, previous stent placement, aneurysm size, and morphology on aneurysm occlusion were performed.
RESULTS: The 1- and 2+-year imaging follow-ups were performed, on average, 13 and 28 months postprocedure. At 2+-year follow-up, clinical data were 100% complete and imaging data were complete for 103/116 aneurysms (88.8%) with a 93.2% occlusion rate. From 0 to 6 months, TIA, minor stroke, and major stroke rates were 4.2%, 3.4%, and 0.8% respectively. After 6 months, 1 patient had a TIA of uncertain cause, with an overall Pipeline Embolization Device-related mortality rate of 0.8%. An incorporated vessel was significant for a delay in occlusion (P = .009) and nonocclusion at 6 months and 1 year, with a delayed mean time of occlusion from 9.1 months (95% CI, 7.1-11.1 months) to 16.7 months (95% CI, 11.4-22.0 months). Other factors were nonsignificant.
CONCLUSIONS: The Pipeline Embolization Device demonstrates continued very high closure rates at 2+ years, with few delayed clinical adverse sequelae. The presence of an incorporated vessel in the wall of the aneurysm causes a delay in occlusion that approaches sidewall closure rates by 2 years.
© 2015 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2015        PMID: 25999412      PMCID: PMC7968755          DOI: 10.3174/ajnr.A4329

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  26 in total

1.  Estimating the proportion of intracranial aneurysms likely to be amenable to treatment with the pipeline embolization device.

Authors:  Waleed Brinjikji; Harry J Cloft; David Fiorella; Giuseppe Lanzino; David F Kallmes
Journal:  J Neurointerv Surg       Date:  2011-12-02       Impact factor: 5.836

2.  Treatment of intracranial aneurysms using the pipeline flow-diverter embolization device: a single-center experience with long-term follow-up results.

Authors:  I Saatci; K Yavuz; C Ozer; S Geyik; H S Cekirge
Journal:  AJNR Am J Neuroradiol       Date:  2012-07-19       Impact factor: 3.825

3.  Extending the indications of flow diversion to small, unruptured, saccular aneurysms of the anterior circulation.

Authors:  Nohra Chalouhi; Robert M Starke; Steven Yang; Cory D Bovenzi; Stavropoula Tjoumakaris; David Hasan; L Fernando Gonzalez; Robert Rosenwasser; Pascal Jabbour
Journal:  Stroke       Date:  2013-11-19       Impact factor: 7.914

4.  Treatment of intracranial aneurysms by functional reconstruction of the parent artery: the Budapest experience with the pipeline embolization device.

Authors:  I Szikora; Z Berentei; Z Kulcsar; M Marosfoi; Z S Vajda; W Lee; A Berez; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2010-02-11       Impact factor: 3.825

5.  Pre-procedure P2Y12 reaction units value predicts perioperative thromboembolic and hemorrhagic complications in patients with cerebral aneurysms treated with the Pipeline Embolization Device.

Authors:  Josser E Delgado Almandoz; Benjamin M Crandall; Jill M Scholz; Jennifer L Fease; Ruth E Anderson; Yasha Kadkhodayan; David E Tubman
Journal:  J Neurointerv Surg       Date:  2013-01-12       Impact factor: 5.836

6.  Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: high intra-aneurysmal pressure remains regardless of flow velocity reduction.

Authors:  Yasuhiro Shobayashi; Satoshi Tateshima; Ryuichi Kakizaki; Ryo Sudo; Kazuo Tanishita; Fernando Viñuela
Journal:  J Neurointerv Surg       Date:  2012-10-09       Impact factor: 5.836

7.  Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience.

Authors:  Pedro Lylyk; Carlos Miranda; Rosana Ceratto; Angel Ferrario; Esteban Scrivano; Hugh Ramirez Luna; Aaron L Berez; Quang Tran; Peter K Nelson; David Fiorella
Journal:  Neurosurgery       Date:  2009-04       Impact factor: 4.654

8.  Canadian experience with the pipeline embolization device for repair of unruptured intracranial aneurysms.

Authors:  C J O'Kelly; J Spears; M Chow; J Wong; M Boulton; A Weill; R A Willinsky; M Kelly; T R Marotta
Journal:  AJNR Am J Neuroradiol       Date:  2012-08-02       Impact factor: 3.825

9.  Cerebral hyperperfusion after flow diversion of large intracranial aneurysms.

Authors:  Albert Ho Yuen Chiu; Jason Wenderoth
Journal:  J Neurointerv Surg       Date:  2012-11-27       Impact factor: 5.836

10.  Effect of antiplatelet therapy on thromboembolism after flow diversion with the pipeline embolization device.

Authors:  Robert S Heller; Venkata Dandamudi; Michael Lanfranchi; Adel M Malek
Journal:  J Neurosurg       Date:  2013-08-23       Impact factor: 5.115

View more
  27 in total

1.  Rapid delayed growth of ruptured supraclinoid blister aneurysm after successful flow diverting stent treatment.

Authors:  Stefan Thomas Lang; Zarina Assis; John H Wong; William Morrish; Alim P Mitha
Journal:  BMJ Case Rep       Date:  2016-07-19

2.  Open-cell stent and use of cone-beam CT enables a safe and effective coil embolization of true ophthalmic artery and anterior choroidal artery aneurysms with preservation of parent vessel: Clinical and angiographic results.

Authors:  Samuel Y Hou; Anna Luisa Kühn; Ajit S Puri; Ajay K Wakhloo
Journal:  Interv Neuroradiol       Date:  2017-12-14       Impact factor: 1.610

3.  Pipeline Embolization Device for Pericallosal Artery Aneurysms: A Retrospective Single Center Safety and Efficacy Study.

Authors:  Katyucia De Macedo Rodrigues; Anna Luisa Kühn; Takamitsu Tamura; Guilherme Dabus; Peter Kan; Miklos G Marosfoi; J Diego Lozano; Mary Perras; Christopher Brooks; Mary C Howk; Samuel Y Hou; David E Rex; Francesco Massari; Matthew J Gounis; Ajay K Wakhloo; Ajit S Puri
Journal:  Oper Neurosurg (Hagerstown)       Date:  2018-04-01       Impact factor: 2.703

4.  FRED Flow Diverter: A Study on Safety and Efficacy in a Consecutive Group of 50 Patients.

Authors:  H Luecking; T Engelhorn; S Lang; P Goelitz; S Kloska; K Roessler; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2017-01-19       Impact factor: 3.825

5.  Entry remnants in flow-diverted aneurysms: Does branch geometry influence aneurysm closure?

Authors:  M Akli Zetchi; Adam A Dmytriw; Albert H Chiu; Brian J Drake; Niki V Alizadeh; Aditya Bharatha; Abhaya V Kulkarni; Thomas R Marotta
Journal:  Interv Neuroradiol       Date:  2018-06-05       Impact factor: 1.610

6.  Relationship between haemodynamic changes and outcomes of intracranial aneurysms after implantation of the pipeline embolisation device: a single centre study.

Authors:  Junfan Chen; Yisen Zhang; Zhongbin Tian; Wenqiang Li; Qianqian Zhang; Ying Zhang; Jian Liu; Xinjian Yang
Journal:  Interv Neuroradiol       Date:  2019-05-14       Impact factor: 1.610

7.  Two- to five-year follow-up of 78 patients after treatment with the Flow Redirection Endoluminal Device.

Authors:  Hannes Luecking; Arnd Doerfler; Philipp Goelitz; Philip Hoelter; Tobias Engelhorn; Stefan Lang
Journal:  Interv Neuroradiol       Date:  2019-10-09       Impact factor: 1.610

8.  Toward Better Understanding of Flow Diversion in Bifurcation Aneurysms.

Authors:  M Shapiro; A Shapiro; E Raz; T Becske; H Riina; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2018-11-15       Impact factor: 3.825

9.  Pipeline embolization device induced collateral channels in elective flow diversion treatment.

Authors:  Yingming Amy Chen; Brian J Drake; Albert Ho Yuen Chiu; Thomas R Marotta
Journal:  BMJ Case Rep       Date:  2016-03-04

10.  Current Trends and Results of Endovascular Treatment of Unruptured Intracranial Aneurysms at a Single Institution in the Flow-Diverter Era.

Authors:  O Petr; W Brinjikji; H Cloft; D F Kallmes; G Lanzino
Journal:  AJNR Am J Neuroradiol       Date:  2016-01-21       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.