Literature DB >> 23188787

Cerebral hyperperfusion after flow diversion of large intracranial aneurysms.

Albert Ho Yuen Chiu1, Jason Wenderoth.   

Abstract

Cerebral hyperperfusion syndrome has been proposed to be caused by rapidly increased blood flow into chronically hypoperfused parenchyma with resultant impaired autoregulation, and has been noted after clipping of intracranial aneurysms and carotid stenting. The occurrence of the syndrome after endovascular flow diversion, however, has not been previously described. A 52-year-old woman was admitted electively for flow diverter treatment of a recurrent ventral paraclinoid aneurysm arising within a dysplastic segment of the left internal carotid artery. During the immediate postprocedural period the patient was found to have confusion, right hemiparesis, facial droop and dysarthria, which resolved with blood pressure control. Subsequent CT perfusion on day 11 demonstrated mildly elevated cerebral blood flow, cerebral blood volume and permeability values in the left hemisphere.

Entities:  

Mesh:

Year:  2012        PMID: 23188787     DOI: 10.1136/neurintsurg-2012-010479.rep

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  21 in total

1.  Verapamil-induced breakdown of the blood-brain barrier presenting as a transient right middle cerebral artery syndrome.

Authors:  Jonathan Pace; Jeffrey Nelson; Abhishek Ray; Yin Hu
Journal:  Interv Neuroradiol       Date:  2017-09-28       Impact factor: 1.610

2.  Changes in contrast transit times on digital subtraction angiography post-Pipeline Embolization Device deployment.

Authors:  Ahmed E Hussein; Andreas Linninger; Sophia F Shakur; Fady T Charbel; Chih-Yang Hsu; Fady T Charbel; Ali Alaraj
Journal:  Interv Neuroradiol       Date:  2017-01-17       Impact factor: 1.610

3.  Aneurysm size and the Windkessel effect: An analysis of contrast intensity in digital subtraction angiography.

Authors:  Ahmed E Hussein; Darian R Esfahani; Andreas Linninger; Fady T Charbel; Chih-Yang Hsu; Fady T Charbel; Ali Alaraj
Journal:  Interv Neuroradiol       Date:  2017-04-26       Impact factor: 1.610

4.  Long-Term Follow-Up Results following Elective Treatment of Unruptured Intracranial Aneurysms with the Pipeline Embolization Device.

Authors:  A H Y Chiu; A K Cheung; J D Wenderoth; L De Villiers; H Rice; C C Phatouros; T P Singh; T J Phillips; W McAuliffe
Journal:  AJNR Am J Neuroradiol       Date:  2015-05-21       Impact factor: 3.825

5.  Use of time attenuation curves to determine steady-state characteristics before C-arm CT measurement of cerebral blood volume.

Authors:  Jildaz Caroff; Pakrit Jittapiromsak; Daniel Ruijters; Nidhal Benachour; Cristian Mihalea; Aymeric Rouchaud; Hiroaki Neki; Léon Ikka; Jacques Moret; Laurent Spelle
Journal:  Neuroradiology       Date:  2014-01-23       Impact factor: 2.804

Review 6.  Flow Diversion in Ruptured Intracranial Aneurysms: A Meta-Analysis.

Authors:  T P Madaelil; C J Moran; D T Cross; A P Kansagra
Journal:  AJNR Am J Neuroradiol       Date:  2016-12-22       Impact factor: 3.825

7.  Middle cerebral artery pressure changes following Pipeline flow diversion.

Authors:  Denise Brunozzi; Sophia F Shakur; Fady T Charbel; Ali Alaraj
Journal:  Interv Neuroradiol       Date:  2018-02-13       Impact factor: 1.610

8.  Quantitative assessment of parent vessel and distal intracranial hemodynamics following pipeline flow diversion.

Authors:  Sophia F Shakur; Victor A Aletich; Sepideh Amin-Hanjani; Ahmed E Hussein; Fady T Charbel; Ali Alaraj
Journal:  Interv Neuroradiol       Date:  2016-10-04       Impact factor: 1.610

9.  Intracranial contrast transit times on digital subtraction angiography decrease more in patients with delayed intraparenchymal hemorrhage after Pipeline.

Authors:  Denise Brunozzi; Sophia F Shakur; Fady T Charbel; Ali Alaraj
Journal:  Interv Neuroradiol       Date:  2017-12-12       Impact factor: 1.610

10.  Risk Factors for Hemorrhagic Complications following Pipeline Embolization Device Treatment of Intracranial Aneurysms: Results from the International Retrospective Study of the Pipeline Embolization Device.

Authors:  W Brinjikji; G Lanzino; H J Cloft; A H Siddiqui; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-06       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.