Literature DB >> 29239687

Open-cell stent and use of cone-beam CT enables a safe and effective coil embolization of true ophthalmic artery and anterior choroidal artery aneurysms with preservation of parent vessel: Clinical and angiographic results.

Samuel Y Hou1, Anna Luisa Kühn2, Ajit S Puri2, Ajay K Wakhloo2.   

Abstract

Background Treatment of true ophthalmic artery (OA) or anterior choroidal artery (AChA) aneurysms with preservation of the parent vessel may be challenging. Flow diverters have limitations when dealing with branch vessels arising from the aneurysm sac. Visual loss or AChA territory infarcts have been reported both for surgical and endovascular treatment. Methods We evaluated the safety and efficacy of an open-cell design, laser-cut, self-expanding Nitinol stent, and use of cone-beam computed tomography (CBCT) for stent-assisted coil embolization. Results A total of seven patients with unruptured OA or AChA aneurysms were enrolled in this prospective small case study and the data were analyzed retrospectively. A complete obliteration was achieved in all aneurysms immediately post-intervention or at six-month follow-up without any evidence for recanalization at up to three-year follow-up. All patients tolerated the procedure well and there was no change in baseline modified Rankin Scale. Conclusions Our study suggests that specific features of an open-cell stent allow a safe and effective treatment of OA or AChA aneurysms with a high technical success rate and excellent mid-term angiographic and clinical outcome. CBCT is a useful intraoperative imaging tool.

Entities:  

Keywords:  Aneurysm; coil embolization; endovascular; internal carotid artery; open-cell stent

Mesh:

Year:  2017        PMID: 29239687      PMCID: PMC5847011          DOI: 10.1177/1591019917747246

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  16 in total

1.  Cone beam computed tomography in the neurointerventional room: beyond vessels.

Authors:  Sameer A Ansari; Salah G Aoun; Bernard R Bendok
Journal:  World Neurosurg       Date:  2011-11-11       Impact factor: 2.104

2.  Contrast-enhanced angiographic cone-beam CT of cerebrovascular stents: experimental optimization and clinical application.

Authors:  N V Patel; M J Gounis; A K Wakhloo; N Noordhoek; J Blijd; D Babic; D Takhtani; S-K Lee; A Norbash
Journal:  AJNR Am J Neuroradiol       Date:  2010-10-21       Impact factor: 3.825

3.  Long-Term Follow-Up Results following Elective Treatment of Unruptured Intracranial Aneurysms with the Pipeline Embolization Device.

Authors:  A H Y Chiu; A K Cheung; J D Wenderoth; L De Villiers; H Rice; C C Phatouros; T P Singh; T J Phillips; W McAuliffe
Journal:  AJNR Am J Neuroradiol       Date:  2015-05-21       Impact factor: 3.825

4.  Surpass flow diverter in the treatment of intracranial aneurysms: a prospective multicenter study.

Authors:  A K Wakhloo; P Lylyk; J de Vries; C Taschner; J Lundquist; A Biondi; M Hartmann; I Szikora; L Pierot; N Sakai; H Imamura; N Sourour; I Rennie; M Skalej; O Beuing; A Bonafé; F Mery; F Turjman; P Brouwer; E Boccardi; L Valvassori; S Derakhshani; M W Litzenberg; M J Gounis
Journal:  AJNR Am J Neuroradiol       Date:  2014-08-14       Impact factor: 3.825

5.  Visual outcomes with flow-diverter stents covering the ophthalmic artery for treatment of internal carotid artery aneurysms.

Authors:  A Rouchaud; O Leclerc; Y Benayoun; S Saleme; Y Camilleri; F D'Argento; M-P Boncoeur; P-Y Robert; C Mounayer
Journal:  AJNR Am J Neuroradiol       Date:  2014-10-22       Impact factor: 3.825

6.  Endovascular treatment of unruptured aneurysms.

Authors:  D Roy; G Milot; J Raymond
Journal:  Stroke       Date:  2001-09       Impact factor: 7.914

7.  Endovascular coil embolization for anterior choroidal artery aneurysms.

Authors:  Byung Moon Kim; Dong Ik Kim; Eun Chul Chung; Sun Yong Kim; Yong Sam Shin; Sung Il Park; Dong Joon Kim; Sang Hyun Suh; Chun Sik Choi; Yu Sam Won
Journal:  Neuroradiology       Date:  2007-11-10       Impact factor: 2.804

8.  The Fate of Side Branches Covered by Flow Diverters-Results from 140 Patients.

Authors:  Pervinder Bhogal; Oliver Ganslandt; Hansjörg Bäzner; Hans Henkes; Marta Aguilar Pérez
Journal:  World Neurosurg       Date:  2017-04-21       Impact factor: 2.104

9.  Blood flow disturbance in perforating arteries attributable to aneurysm surgery.

Authors:  Tatsuya Sasaki; Namio Kodama; Masato Matsumoto; Kyouichi Suzuki; Yutaka Konno; Jun Sakuma; Yuji Endo; Masahiro Oinuma
Journal:  J Neurosurg       Date:  2007-07       Impact factor: 5.115

10.  Quantitative analysis of high-resolution, contrast-enhanced, cone-beam CT for the detection of intracranial in-stent hyperplasia.

Authors:  Thomas F Flood; Imramsjah M J van der Bom; Lara Strittmatter; Ajit S Puri; Gregory M Hendricks; Ajay K Wakhloo; Matthew J Gounis
Journal:  J Neurointerv Surg       Date:  2014-01-30       Impact factor: 5.836

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.