Literature DB >> 25969023

Postprocessing algorithms to minimize fixed-pattern artifact and reduce trigger jitter in swept source optical coherence tomography.

Gangjun Liu, Ou Tan, Simon S Gao, Alex D Pechauer, ByungKun Lee, Chen D Lu, James G Fujimoto, David Huang.   

Abstract

We propose methods to align interferograms affected by trigger jitter to a reference interferogram based on the information (amplitude/phase) at a fixed-pattern noise location to reduce residual fixed-pattern noise and improve the phase stability of swept source optical coherence tomography (SS-OCT) systems. One proposed method achieved this by introducing a wavenumber shift (k-shift) in the interferograms of interest and searching for the k-shift that minimized the fixed-pattern noise amplitude. The other method calculated the relative k-shift using the phase information at the residual fixed-pattern noise location. Repeating this wavenumber alignment procedure for all A-lines of interest produced fixed-pattern noise free and phase stable OCT images. A system incorporating these correction routines was used for human retina OCT and Doppler OCT imaging. The results from the two methods were compared, and it was found that the intensity-based method provided better results.

Entities:  

Mesh:

Year:  2015        PMID: 25969023      PMCID: PMC4523376          DOI: 10.1364/OE.23.009824

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  10 in total

1.  Phase-sensitive optical coherence tomography at up to 370,000 lines per second using buffered Fourier domain mode-locked lasers.

Authors:  Desmond C Adler; Robert Huber; James G Fujimoto
Journal:  Opt Lett       Date:  2007-03-15       Impact factor: 3.776

2.  Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting.

Authors:  S Yun; G Tearney; J de Boer; B Bouma
Journal:  Opt Express       Date:  2004-10-04       Impact factor: 3.894

3.  Phase-resolved optical frequency domain imaging.

Authors:  B Vakoc; S Yun; J de Boer; G Tearney; B Bouma
Journal:  Opt Express       Date:  2005-07-11       Impact factor: 3.894

4.  Multi-MHz retinal OCT.

Authors:  Thomas Klein; Wolfgang Wieser; Lukas Reznicek; Aljoscha Neubauer; Anselm Kampik; Robert Huber
Journal:  Biomed Opt Express       Date:  2013-08-30       Impact factor: 3.732

5.  High-penetration swept source Doppler optical coherence angiography by fully numerical phase stabilization.

Authors:  Young-Joo Hong; Shuichi Makita; Franck Jaillon; Myeong Jin Ju; Eun Jung Min; Byeong Ha Lee; Masahide Itoh; Masahiro Miura; Yoshiaki Yasuno
Journal:  Opt Express       Date:  2012-01-30       Impact factor: 3.894

6.  Phase-stabilized optical frequency domain imaging at 1-µm for the measurement of blood flow in the human choroid.

Authors:  Boy Braaf; Koenraad A Vermeer; Victor Arni D P Sicam; Elsbeth van Zeeburg; Jan C van Meurs; Johannes F de Boer
Journal:  Opt Express       Date:  2011-10-10       Impact factor: 3.894

7.  Phase-sensitive swept-source optical coherence tomography imaging of the human retina with a vertical cavity surface-emitting laser light source.

Authors:  WooJhon Choi; Benjamin Potsaid; Vijaysekhar Jayaraman; Bernhard Baumann; Ireneusz Grulkowski; Jonathan J Liu; Chen D Lu; Alex E Cable; David Huang; Jay S Duker; James G Fujimoto
Journal:  Opt Lett       Date:  2013-02-01       Impact factor: 3.776

8.  Doppler velocity detection limitations in spectrometer-based versus swept-source optical coherence tomography.

Authors:  Hansford C Hendargo; Ryan P McNabb; Al-Hafeez Dhalla; Neal Shepherd; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2011-07-06       Impact factor: 3.732

9.  Total retinal blood flow measurement with ultrahigh speed swept source/Fourier domain OCT.

Authors:  Bernhard Baumann; Benjamin Potsaid; Martin F Kraus; Jonathan J Liu; David Huang; Joachim Hornegger; Alex E Cable; Jay S Duker; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2011-05-13       Impact factor: 3.732

10.  Imaging vibrating vocal folds with a high speed 1050 nm swept source OCT and ODT.

Authors:  Gangjun Liu; Marc Rubinstein; Arya Saidi; Wenjuan Qi; Allen Foulad; Brian Wong; Zhongping Chen
Journal:  Opt Express       Date:  2011-06-06       Impact factor: 3.894

  10 in total
  12 in total

1.  Imaging the anterior eye with dynamic-focus swept-source optical coherence tomography.

Authors:  Johnny P Su; Yan Li; Maolong Tang; Liang Liu; Alex D Pechauer; David Huang; Gangjun Liu
Journal:  J Biomed Opt       Date:  2015       Impact factor: 3.170

Review 2.  Optical coherence tomography angiography in preclinical neuroimaging.

Authors:  Woo June Choi
Journal:  Biomed Eng Lett       Date:  2019-07-02

3.  Handheld optical coherence tomography angiography.

Authors:  Jianlong Yang; Liang Liu; J Peter Campbell; David Huang; Gangjun Liu
Journal:  Biomed Opt Express       Date:  2017-03-22       Impact factor: 3.732

4.  Optical coherence tomography angiography of stimulus evoked hemodynamic responses in individual retinal layers.

Authors:  Taeyoon Son; Benquan Wang; Damber Thapa; Yiming Lu; Yanjun Chen; Dingcai Cao; Xincheng Yao
Journal:  Biomed Opt Express       Date:  2016-07-29       Impact factor: 3.732

5.  Split-spectrum phase-gradient optical coherence tomography angiography.

Authors:  Gangjun Liu; Yali Jia; Alex D Pechauer; Rahul Chandwani; David Huang
Journal:  Biomed Opt Express       Date:  2016-07-11       Impact factor: 3.732

6.  Phase-noise analysis of swept-source optical coherence tomography systems.

Authors:  Yuye Ling; Yu Gan; Xinwen Yao; Christine P Hendon
Journal:  Opt Lett       Date:  2017-04-01       Impact factor: 3.776

7.  Extended axial imaging range, widefield swept source optical coherence tomography angiography.

Authors:  Gangjun Liu; Jianlong Yang; Jie Wang; Yan Li; Pengxiao Zang; Yali Jia; David Huang
Journal:  J Biophotonics       Date:  2017-05-11       Impact factor: 3.207

8.  Correction of non-uniform angular velocity and sub-pixel jitter in optical scanning.

Authors:  Bartlomiej Kowalski; Vyas Akondi; Alfredo Dubra
Journal:  Opt Express       Date:  2022-01-03       Impact factor: 3.894

9.  Functional optical coherence tomography of neurovascular coupling interactions in the retina.

Authors:  Taeyoon Son; Minhaj Alam; Devrim Toslak; Benquan Wang; Yiming Lu; Xincheng Yao
Journal:  J Biophotonics       Date:  2018-07-27       Impact factor: 3.207

10.  Correlating optical coherence elastography based strain measurements with collagen content of the human ovarian tissue.

Authors:  Sreyankar Nandy; Hassan S Salehi; Tianheng Wang; Xiaohong Wang; Melinda Sanders; Angela Kueck; Molly Brewer; Quing Zhu
Journal:  Biomed Opt Express       Date:  2015-09-03       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.