Literature DB >> 21997098

Phase-stabilized optical frequency domain imaging at 1-µm for the measurement of blood flow in the human choroid.

Boy Braaf1, Koenraad A Vermeer, Victor Arni D P Sicam, Elsbeth van Zeeburg, Jan C van Meurs, Johannes F de Boer.   

Abstract

In optical frequency domain imaging (OFDI) the measurement of interference fringes is not exactly reproducible due to small instabilities in the swept-source laser, the interferometer and the data-acquisition hardware. The resulting variation in wavenumber sampling makes phase-resolved detection and the removal of fixed-pattern noise challenging in OFDI. In this paper this problem is solved by a new post-processing method in which interference fringes are resampled to the exact same wavenumber space using a simultaneously recorded calibration signal. This method is implemented in a high-speed (100 kHz) high-resolution (6.5 µm) OFDI system at 1-µm and is used for the removal of fixed-pattern noise artifacts and for phase-resolved blood flow measurements in the human choroid. The system performed close to the shot-noise limit (<1dB) with a sensitivity of 99.1 dB for a 1.7 mW sample arm power. Suppression of fixed-pattern noise artifacts is shown up to 39.0 dB which effectively removes all artifacts from the OFDI-images. The clinical potential of the system is shown by the detection of choroidal blood flow in a healthy volunteer and the detection of tissue reperfusion in a patient after a retinal pigment epithelium and choroid transplantation.

Entities:  

Mesh:

Year:  2011        PMID: 21997098     DOI: 10.1364/OE.19.020886

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  52 in total

1.  Multi-MHz retinal OCT.

Authors:  Thomas Klein; Wolfgang Wieser; Lukas Reznicek; Aljoscha Neubauer; Anselm Kampik; Robert Huber
Journal:  Biomed Opt Express       Date:  2013-08-30       Impact factor: 3.732

2.  In vivo imaging of human vasculature in the chorioretinal complex using phase-variance contrast method with phase-stabilized 1-μm swept-source optical coherence tomography.

Authors:  Raju Poddar; Dae Yu Kim; John S Werner; Robert J Zawadzki
Journal:  J Biomed Opt       Date:  2014-12       Impact factor: 3.170

3.  Postprocessing algorithms to minimize fixed-pattern artifact and reduce trigger jitter in swept source optical coherence tomography.

Authors:  Gangjun Liu; Ou Tan; Simon S Gao; Alex D Pechauer; ByungKun Lee; Chen D Lu; James G Fujimoto; David Huang
Journal:  Opt Express       Date:  2015-04-20       Impact factor: 3.894

4.  Depth-encoded all-fiber swept source polarization sensitive OCT.

Authors:  Zhao Wang; Hsiang-Chieh Lee; Osman Oguz Ahsen; ByungKun Lee; WooJhon Choi; Benjamin Potsaid; Jonathan Liu; Vijaysekhar Jayaraman; Alex Cable; Martin F Kraus; Kaicheng Liang; Joachim Hornegger; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2014-08-01       Impact factor: 3.732

5.  Phase-sensitive optical coherence tomography using an Vernier-tuned distributed Bragg reflector swept laser in the mouse middle ear.

Authors:  Jesung Park; Esteban F Carbajal; Xi Chen; John S Oghalai; Brian E Applegate
Journal:  Opt Lett       Date:  2014-11-01       Impact factor: 3.776

6.  Stability in computed optical interferometric tomography (part I): stability requirements.

Authors:  Nathan D Shemonski; Steven G Adie; Yuan-Zhi Liu; Fredrick A South; P Scott Carney; Stephen A Boppart
Journal:  Opt Express       Date:  2014-08-11       Impact factor: 3.894

7.  Complex differential variance algorithm for optical coherence tomography angiography.

Authors:  Ahhyun S Nam; Isabel Chico-Calero; Benjamin J Vakoc
Journal:  Biomed Opt Express       Date:  2014-10-07       Impact factor: 3.732

8.  Optical frequency domain imaging of ex vivo pulmonary resection specimens: obtaining one to one image to histopathology correlation.

Authors:  Lida P Hariri; Matthew B Applegate; Mari Mino-Kenudson; Eugene J Mark; Brett E Bouma; Guillermo J Tearney; Melissa J Suter
Journal:  J Vis Exp       Date:  2013-01-22       Impact factor: 1.355

9.  Phase-sensitive swept-source optical coherence tomography imaging of the human retina with a vertical cavity surface-emitting laser light source.

Authors:  WooJhon Choi; Benjamin Potsaid; Vijaysekhar Jayaraman; Bernhard Baumann; Ireneusz Grulkowski; Jonathan J Liu; Chen D Lu; Alex E Cable; David Huang; Jay S Duker; James G Fujimoto
Journal:  Opt Lett       Date:  2013-02-01       Impact factor: 3.776

10.  Phase-stable swept source OCT angiography in human skin using an akinetic source.

Authors:  Zhe Chen; Mengyang Liu; Michael Minneman; Laurin Ginner; Erich Hoover; Harald Sattmann; Marco Bonesi; Wolfgang Drexler; Rainer A Leitgeb
Journal:  Biomed Opt Express       Date:  2016-07-12       Impact factor: 3.732

View more