Literature DB >> 28362762

Phase-noise analysis of swept-source optical coherence tomography systems.

Yuye Ling, Yu Gan, Xinwen Yao, Christine P Hendon.   

Abstract

We propose a new model to characterize the phase noise in swept-source optical coherence tomography (SS-OCT). The new model explicitly incorporates scanning variability, timing jitter, and sample location in addition to intensity noise (shot noise). The model was analyzed and validated by using both Monte Carlo methods and experiments. We suggest that the proposed model can be used as a guideline for future SS-OCT experimental designs.

Entities:  

Year:  2017        PMID: 28362762      PMCID: PMC6080202          DOI: 10.1364/OL.42.001333

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  10 in total

1.  Spectral-domain phase microscopy.

Authors:  Michael A Choma; Audrey K Ellerbee; Changhuei Yang; Tony L Creazzo; Joseph A Izatt
Journal:  Opt Lett       Date:  2005-05-15       Impact factor: 3.776

2.  Phase-sensitive optical coherence tomography at up to 370,000 lines per second using buffered Fourier domain mode-locked lasers.

Authors:  Desmond C Adler; Robert Huber; James G Fujimoto
Journal:  Opt Lett       Date:  2007-03-15       Impact factor: 3.776

3.  Real-time fiber-based multi-functional spectral-domain optical coherence tomography at 1.3 microm.

Authors:  B Park; Mark C Pierce; Barry Cense; Seok-Hyun Yun; Mircea Mujat; Guillermo Tearney; Brett Bouma; Johannes de Boer
Journal:  Opt Express       Date:  2005-05-30       Impact factor: 3.894

4.  Phase-resolved optical frequency domain imaging.

Authors:  B Vakoc; S Yun; J de Boer; G Tearney; B Bouma
Journal:  Opt Express       Date:  2005-07-11       Impact factor: 3.894

5.  Flow velocity estimation using joint Spectral and Time domain Optical Coherence Tomography.

Authors:  Maciej Szkulmowski; Anna Szkulmowska; Tomasz Bajraszewski; Andrzej Kowalczyk; Maciej Wojtkowski
Journal:  Opt Express       Date:  2008-04-28       Impact factor: 3.894

6.  Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 kHz with adjustable imaging range.

Authors:  Michalina Gora; Karol Karnowski; Maciej Szkulmowski; Bartlomiej J Kaluzny; Robert Huber; Andrzej Kowalczyk; Maciej Wojtkowski
Journal:  Opt Express       Date:  2009-08-17       Impact factor: 3.894

7.  Postprocessing algorithms to minimize fixed-pattern artifact and reduce trigger jitter in swept source optical coherence tomography.

Authors:  Gangjun Liu; Ou Tan; Simon S Gao; Alex D Pechauer; ByungKun Lee; Chen D Lu; James G Fujimoto; David Huang
Journal:  Opt Express       Date:  2015-04-20       Impact factor: 3.894

8.  Akinetic all-semiconductor programmable swept-source at 1550 nm and 1310 nm with centimeters coherence length.

Authors:  M Bonesi; M P Minneman; J Ensher; B Zabihian; H Sattmann; P Boschert; E Hoover; R A Leitgeb; M Crawford; W Drexler
Journal:  Opt Express       Date:  2014-02-10       Impact factor: 3.894

9.  Doppler flow imaging of cytoplasmic streaming using spectral domain phase microscopy.

Authors:  Michael A Choma; Audrey K Ellerbee; Siavash Yazdanfar; Joseph A Izatt
Journal:  J Biomed Opt       Date:  2006 Mar-Apr       Impact factor: 3.170

10.  Phase-sensitive swept-source optical coherence tomography imaging of the human retina with a vertical cavity surface-emitting laser light source.

Authors:  WooJhon Choi; Benjamin Potsaid; Vijaysekhar Jayaraman; Bernhard Baumann; Ireneusz Grulkowski; Jonathan J Liu; Chen D Lu; Alex E Cable; David Huang; Jay S Duker; James G Fujimoto
Journal:  Opt Lett       Date:  2013-02-01       Impact factor: 3.776

  10 in total
  5 in total

Review 1.  Optical coherence tomography angiography in preclinical neuroimaging.

Authors:  Woo June Choi
Journal:  Biomed Eng Lett       Date:  2019-07-02

2.  Phase-stability optimization of swept-source optical coherence tomography.

Authors:  Sucbei Moon; Zhongping Chen
Journal:  Biomed Opt Express       Date:  2018-10-09       Impact factor: 3.732

3.  Compressed sensing-enabled phase-sensitive swept-source optical coherence tomography.

Authors:  Yuye Ling; William Meiniel; Rajinder Singh-Moon; Elsa Angelini; Jean-Christophe Olivo-Marin; Christine P Hendon
Journal:  Opt Express       Date:  2019-01-21       Impact factor: 3.894

4.  Highly phase-stable 200 kHz swept-source optical coherence tomography based on KTN electro-optic deflector.

Authors:  Yuye Ling; Xinwen Yao; Christine P Hendon
Journal:  Biomed Opt Express       Date:  2017-07-18       Impact factor: 3.732

5.  Multicontrast endomyocardial imaging by single-channel high-resolution cross-polarization optical coherence tomography.

Authors:  Xinwen Yao; Yu Gan; Yuye Ling; Charles C Marboe; Christine P Hendon
Journal:  J Biophotonics       Date:  2018-01-10       Impact factor: 3.207

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.