Literature DB >> 26662065

Imaging the anterior eye with dynamic-focus swept-source optical coherence tomography.

Johnny P Su, Yan Li, Maolong Tang, Liang Liu, Alex D Pechauer, David Huang, Gangjun Liu.   

Abstract

A custom-built dynamic-focus swept-source optical coherence tomography (SS-OCT) system with a central wavelength of 1310 nm was used to image the anterior eye from the cornea to the lens. An electrically tunable lens was utilized to dynamically control the positions of focusing planes over the imaging range of 10 mm. The B-scan images were acquired consecutively at the same position but with different focus settings. The B-scan images were then registered and averaged after filtering the out-of-focus regions using a Gaussian window. By fusing images obtained at different depth focus locations, high-resolution and high signal-strength images were obtained over the entire imaging depth. In vivo imaging of human anterior segment was demonstrated. The performance of the system was compared with two commercial OCT systems. The human eye ciliary body was better visualized with the dynamic-focusing SS-OCT system than using the commercial 840 and 1310 nm OCT systems. The sulcus-to-sulcus distance was measured, and the result agreed with that acquired with ultrasound biomicroscopy

Entities:  

Mesh:

Year:  2015        PMID: 26662065      PMCID: PMC4674840          DOI: 10.1117/1.JBO.20.12.126002

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  18 in total

1.  Performance of fourier domain vs. time domain optical coherence tomography.

Authors:  R Leitgeb; C Hitzenberger; Adolf Fercher
Journal:  Opt Express       Date:  2003-04-21       Impact factor: 3.894

2.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

3.  Depth-encoded all-fiber swept source polarization sensitive OCT.

Authors:  Zhao Wang; Hsiang-Chieh Lee; Osman Oguz Ahsen; ByungKun Lee; WooJhon Choi; Benjamin Potsaid; Jonathan Liu; Vijaysekhar Jayaraman; Alex Cable; Martin F Kraus; Kaicheng Liang; Joachim Hornegger; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2014-08-01       Impact factor: 3.732

4.  Swept source optical coherence tomography Gabor fusion splicing technique for microscopy of thick samples using a deformable mirror.

Authors:  Christopher Costa; Adrian Bradu; John Rogers; Pauline Phelan; Adrian Podoleanu
Journal:  J Biomed Opt       Date:  2015-01       Impact factor: 3.170

5.  Microscopic OCT imaging with focus extension by ultrahigh-speed acousto-optic tunable lens and stroboscopic illumination.

Authors:  Ireneusz Grulkowski; Krzysztof Szulzycki; Maciej Wojtkowski
Journal:  Opt Express       Date:  2014-12-29       Impact factor: 3.894

6.  Microscope-integrated intraoperative OCT with electrically tunable focus and heads-up display for imaging of ophthalmic surgical maneuvers.

Authors:  Yuankai K Tao; Sunil K Srivastava; Justis P Ehlers
Journal:  Biomed Opt Express       Date:  2014-05-20       Impact factor: 3.732

7.  Anterior chamber optical coherence tomography study of human natural accommodation in a 19-year-old albino.

Authors:  Georges Baikoff; Eric Lutun; Jay Wei; Caroline Ferraz
Journal:  J Cataract Refract Surg       Date:  2004-03       Impact factor: 3.351

Review 8.  High-resolution ultrasound imaging of the eye - a review.

Authors:  Ronald H Silverman
Journal:  Clin Exp Ophthalmol       Date:  2008-12-09       Impact factor: 4.207

9.  Dual channel dual focus optical coherence tomography for imaging accommodation of the eye.

Authors:  Chuanqing Zhou; Jianhua Wang; Shuliang Jiao
Journal:  Opt Express       Date:  2009-05-25       Impact factor: 3.894

10.  Simultaneous real-time imaging of the ocular anterior segment including the ciliary muscle during accommodation.

Authors:  Yilei Shao; Aizhu Tao; Hong Jiang; Meixiao Shen; Jianguang Zhong; Fan Lu; Jianhua Wang
Journal:  Biomed Opt Express       Date:  2013-02-21       Impact factor: 3.732

View more
  9 in total

1.  Handheld optical coherence tomography angiography.

Authors:  Jianlong Yang; Liang Liu; J Peter Campbell; David Huang; Gangjun Liu
Journal:  Biomed Opt Express       Date:  2017-03-22       Impact factor: 3.732

2.  Three-dimensional visualization of opacifications in the murine crystalline lens by in vivo optical coherence tomography.

Authors:  Pablo Eugui; Danielle J Harper; Stefan Kummer; Antonia Lichtenegger; Johanna Gesperger; Tanja Himmel; Marco Augustin; Conrad W Merkle; Martin Glösmann; Bernhard Baumann
Journal:  Biomed Opt Express       Date:  2020-03-19       Impact factor: 3.732

3.  Extended axial imaging range, widefield swept source optical coherence tomography angiography.

Authors:  Gangjun Liu; Jianlong Yang; Jie Wang; Yan Li; Pengxiao Zang; Yali Jia; David Huang
Journal:  J Biophotonics       Date:  2017-05-11       Impact factor: 3.207

4.  Portable boom-type ultrahigh-resolution OCT with an integrated imaging probe for supine position retinal imaging.

Authors:  Zhengyu Duan; Kai Huang; Zhongzhou Luo; Ke Ma; Gengyuan Wang; Xiaodong Hu; Jinze Zhang; Xiaoling Luo; Yuancong Huang; Gangjun Liu; Xiaoyan Ding; Peng Xiao; Jin Yuan
Journal:  Biomed Opt Express       Date:  2022-05-10       Impact factor: 3.562

5.  Gabor fusion master slave optical coherence tomography.

Authors:  Ramona Cernat; Adrian Bradu; Niels Møller Israelsen; Ole Bang; Sylvain Rivet; Pearse A Keane; David-Garway Heath; Ranjan Rajendram; Adrian Podoleanu
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

Review 6.  Optical Coherence Tomography Angiography.

Authors:  Simon S Gao; Yali Jia; Miao Zhang; Johnny P Su; Gangjun Liu; Thomas S Hwang; Steven T Bailey; David Huang
Journal:  Invest Ophthalmol Vis Sci       Date:  2016-07-01       Impact factor: 4.799

7.  Near-infrared laser thermal conjunctivoplasty.

Authors:  Jianlong Yang; Rahul Chandwani; Varun Gopinatth; Tim Boyce; Stephen C Pflugfelder; David Huang; Gangjun Liu
Journal:  Sci Rep       Date:  2018-03-01       Impact factor: 4.379

8.  The Role of Hi-Tech Devices in Assessment of Corneal Healing in Patients with Neurotrophic Keratopathy.

Authors:  Leandro Inferrera; Emanuela Aragona; Adam Wylęgała; Antonio Valastro; Gianluigi Latino; Elisa I Postorino; Romana Gargano; Bogusława Orzechowska-Wylęgała; Edward Wylęgała; Anna M Roszkowska
Journal:  J Clin Med       Date:  2022-03-14       Impact factor: 4.241

9.  High speed, long range, deep penetration swept source OCT for structural and angiographic imaging of the anterior eye.

Authors:  Siyu Chen; Benjamin Potsaid; Yan Li; Junhong Lin; Yunchan Hwang; Eric M Moult; Jason Zhang; David Huang; James G Fujimoto
Journal:  Sci Rep       Date:  2022-01-19       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.