Literature DB >> 25957588

Anthropometric study of the proximal radius: does radial head implant fit in all cases?

Soo Hwan Kang1, Dong Yeop Kim, Hyunwoo Park, Hyun Seok Song.   

Abstract

PURPOSE: The purpose of this study was to evaluate anthropometry of the radial head and neck and compare the results with radial head prosthesis in current use.
METHODS: A total of 144 cases were analysed that underwent antero-posterior (AP) elbow radiographs in full supination and extension position between January 2013 and April 2013. Mean age was 54.3 years (range, 21-79). The distance between the articular surface and the radial tuberosity, the height of the radial head, the diameter of the radial head, and the width of the proximal radioulnar joint were measured. The specifications of 13 products from nine companies were compared with the parameters.
RESULTS: The mean distance between the articular surface and the radial tuberosity was 19.6 mm. Mean height, diameter, and width of the proximal radioulnar joint were 10.6, 22.0, and 8.9 mm, respectively. A violation of the distal biceps insertion will occur in up to 87.5 % of the cases when some of the bipolar implants were used. The height of some of the implant heads was larger than the height of head in our study. Although the height and diameter of the radial head were similar to those of previous reports, the distance between the articular surface of the head and radial tuberosity was different.
CONCLUSION: The anatomical parameters of the proximal radius of the cases, especially the distance between the articular surface of the head and the radial tuberosity, and the radial head implant specifications should be assessed when selecting a radial head implant.

Mesh:

Year:  2015        PMID: 25957588     DOI: 10.1007/s00264-015-2773-z

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  24 in total

1.  The anatomic features of the radial head and their implication for prosthesis design.

Authors:  W Swieszkowski; K Skalski; S Pomianowski; K Kedzior
Journal:  Clin Biomech (Bristol, Avon)       Date:  2001-12       Impact factor: 2.063

2.  Biometry of the radial head: biomechanical implications in pronation and supination.

Authors:  G Captier; F Canovas; N Mercier; E Thomas; F Bonnel
Journal:  Surg Radiol Anat       Date:  2002-11-01       Impact factor: 1.246

3.  Some observations on fractures of the head of the radius with a review of one hundred cases.

Authors:  M L MASON
Journal:  Br J Surg       Date:  1954-09       Impact factor: 6.939

4.  A comparative study between proximal radial morphology and the floating radial head prosthesis.

Authors:  Nebojsa Popovic; Julien Djekic; Roger Lemaire; Philippe Gillet
Journal:  J Shoulder Elbow Surg       Date:  2005 Jul-Aug       Impact factor: 3.019

5.  Reference points for radial head prosthesis size.

Authors:  Job N Doornberg; Durk S Linzel; David Zurakowski; David Ring
Journal:  J Hand Surg Am       Date:  2006-01       Impact factor: 2.230

6.  Radiocapitellar joint stability with bipolar versus monopolar radial head prostheses.

Authors:  Jun-Gyu Moon; Lawrence J Berglund; Domire Zachary; Kai-Nan An; Shawn W O'Driscoll
Journal:  J Shoulder Elbow Surg       Date:  2009-05-07       Impact factor: 3.019

7.  Prosthetic radial head stem pull-out as a mode of failure: a biomechanical study.

Authors:  Dave Shukla; James Fitzsimmons; Kai-Nan An; Shawn O'Driscoll
Journal:  Int Orthop       Date:  2013-09-17       Impact factor: 3.075

8.  Resection of the radial head after Mason type-III fractures of the elbow: follow-up at 16 to 30 years.

Authors:  R P Janssen; J Vegter
Journal:  J Bone Joint Surg Br       Date:  1998-03

9.  The kinematic importance of radial neck length in radial head replacement.

Authors:  F Van Glabbeek; R P van Riet; J A Baumfeld; P G Neale; S W O'Driscoll; B F Morrey; K N An
Journal:  Med Eng Phys       Date:  2005-05       Impact factor: 2.242

10.  Function after early radial head resection for fracture: a retrospective evaluation of 15 patients followed for 3-18 years.

Authors:  M Ikeda; Y Oka
Journal:  Acta Orthop Scand       Date:  2000-04
View more
  1 in total

1.  Beveled posteromedial corner of the radial head: a three-dimensional micro-computed tomography modeling study.

Authors:  Arnold Adikrishna; Young-Ho Shin; Rizki F Zulkarnain; Hanpyo Hong; Yucheng Sun; In-Ho Jeon
Journal:  J Anat       Date:  2017-08-15       Impact factor: 2.610

  1 in total