Literature DB >> 12497220

Biometry of the radial head: biomechanical implications in pronation and supination.

G Captier1, F Canovas, N Mercier, E Thomas, F Bonnel.   

Abstract

The aim of this study was to perform biometry of the proximal extremity of the radius and to characterize the shape of the radial head. Knowledge of the size and shape of the radial head is necessary for the creation of a radial head prosthesis that is anatomically and biomechanically correct. Twenty-seven measurements, focused on the proximal extremity, were done on 96 radii. The shape of the radial head was determined by the difference between the maximum diameter and the minimum diameter. We considered the shape to be circular when the difference was less than 1 mm, and elliptical when the difference was greater than 1 mm. The shape of the radial head was compared with the neck/diaphysis angle. Fifty-seven percent of radial heads were elliptical and 43% were circular. When the head was elliptical the maximum diameter was 22 mm +/-2.9 and the minimum diameter was 20 mm +/-2.8 ( P<0.001). When the head was circular the maximum diameter was 21.2 mm +/-2.4 and the minimum diameter was 20.4 mm +/-2.4 ( P<0.14). The angle between the neck and the diaphysis varied with regard to the shape of the radial head. It was 166.75 degrees +/-3 for the circular heads and 168.62 degrees +/-3.2 for the elliptical heads ( P<0.01). The biomechanics of the circular shape and the elliptical shape are different, involving an adaptation of the angle between the neck and the radial diaphysis. This difference must be taken in consideration in the design of a radial head prosthesis.

Mesh:

Year:  2002        PMID: 12497220     DOI: 10.1007/s00276-002-0059-9

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  14 in total

1.  Morphometric parameters of the radial head: an anatomical study.

Authors:  T C Koslowsky; I Germund; F Beyer; K Mader; C F Krieglstein; J Koebke
Journal:  Surg Radiol Anat       Date:  2007-03-07       Impact factor: 1.246

2.  Anthropometric study of the proximal radius: does radial head implant fit in all cases?

Authors:  Soo Hwan Kang; Dong Yeop Kim; Hyunwoo Park; Hyun Seok Song
Journal:  Int Orthop       Date:  2015-05-10       Impact factor: 3.075

3.  Complications after radial head arthroplasty: a comparison between short-stemmed bipolar and monopolar long-stemmed osteointegrative rigidly fixed prostheses.

Authors:  Yves Gramlich; Eva-Lorine Krausch; Alexander Klug; Johannes Buckup; Kay Schmidt-Horlohé; Reinhard Hoffmann
Journal:  Int Orthop       Date:  2018-09-29       Impact factor: 3.075

4.  Tight-fitting radial head prosthesis: does stem size help prevent painful loosening?

Authors:  Pierre Laumonerie; Nicolas Reina; Claudia Gutierrez; Stephanie Delclaux; Meagan E Tibbo; Nicolas Bonnevialle; Pierre Mansat
Journal:  Int Orthop       Date:  2017-09-21       Impact factor: 3.075

5.  Beveled posteromedial corner of the radial head: a three-dimensional micro-computed tomography modeling study.

Authors:  Arnold Adikrishna; Young-Ho Shin; Rizki F Zulkarnain; Hanpyo Hong; Yucheng Sun; In-Ho Jeon
Journal:  J Anat       Date:  2017-08-15       Impact factor: 2.610

6.  Positioning of longest axis of the radial head in neutral forearm rotation.

Authors:  Miguel Deschrijver; Simon Lamquet; Guillaume Planckaert; Hannes Vermue; Lieven De Wilde; Alexander Van Tongel
Journal:  Shoulder Elbow       Date:  2019-03-04

7.  Morphometric parameters of the radial neck: an anatomical study.

Authors:  T C Koslowsky; F Beyer; I Germund; K Mader; M Jergas; J Koebke
Journal:  Surg Radiol Anat       Date:  2007-05-10       Impact factor: 1.354

Review 8.  Clinical anatomy and biomechanics of the elbow.

Authors:  Kuen Chin; Shakir Hussain; George Mazis; Anand Arya
Journal:  J Clin Orthop Trauma       Date:  2021-06-24

9.  Validation of the contralateral side as reference for selecting radial head implant sizes.

Authors:  Paul W L Ten Berg; Johannes G G Dobbe; Gerhard van Wolfswinkel; Simon D Strackee; Geert J Streekstra
Journal:  Surg Radiol Anat       Date:  2016-01-21       Impact factor: 1.246

10.  Regional differences in the three-dimensional bone microstructure of the radial head: implications for observed fracture patterns.

Authors:  Jetske Viveen; Egon Perilli; Ruurd L Jaarsma; Job N Doornberg; Denise Eygengaal; Gregory I Bain
Journal:  Arch Orthop Trauma Surg       Date:  2020-11-10       Impact factor: 3.067

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.