Literature DB >> 15823475

The kinematic importance of radial neck length in radial head replacement.

F Van Glabbeek1, R P van Riet, J A Baumfeld, P G Neale, S W O'Driscoll, B F Morrey, K N An.   

Abstract

Comminuted radial head fractures can be treated with a radial head implant. The effects of lengthening (2.5 mm, 5 mm) and shortening (2.5 mm, 5 mm) of the radial neck, were compared to the nominal length in six human upper extremity cadavers. Total varus-valgus laxity and ulnar rotation were recorded. We hypothesized that restoring the exact length of the radius is important to maintain normal kinematics in the elbow joint. Lengthening or shortening of more than 2.5 mm significantly changed elbow kinematics. Lengthening caused a significant decrease (p < 0.001) in varus-valgus laxity, with the ulna tracking in varus and external rotation. Shortening caused a significant increase in varus-valgus laxity (p < 0.001) and ulnar rotation (p < 0.001), with the ulna tracking in valgus and internal rotation. Our study suggests that a restoration of radial length is important and that axial understuffing or overstuffing the radiohumeral joint by 2.5 mm or more, will alter elbow kinematics.

Entities:  

Mesh:

Year:  2005        PMID: 15823475     DOI: 10.1016/j.medengphy.2004.04.011

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  17 in total

1.  [Prosthesis after comminuted radial head fractures : midterm results].

Authors:  A Moghaddam; A Lennert; S Studier-Fischer; A Wentzensen; G Zimmermann
Journal:  Unfallchirurg       Date:  2008-12       Impact factor: 1.000

2.  [Endoprosthetics of acute radial head fractures].

Authors:  K J Burkhart; K Wegmann; C Ries; L P Müller
Journal:  Unfallchirurg       Date:  2013-08       Impact factor: 1.000

3.  Can ulnar variance be used to detect overstuffing after radial head arthroplasty?

Authors:  Jun-Gyu Moon; Jin-Ho Hong; Nitin Bither; Won-Yong Shon
Journal:  Clin Orthop Relat Res       Date:  2013-09-13       Impact factor: 4.176

4.  Simple overlay device for determining radial head and neck height.

Authors:  Jun-Gyu Moon; Richard D Southgate; James S Fitzsimmons; Shawn W O'Driscoll
Journal:  Skeletal Radiol       Date:  2010-03-01       Impact factor: 2.199

5.  Anthropometric study of the proximal radius: does radial head implant fit in all cases?

Authors:  Soo Hwan Kang; Dong Yeop Kim; Hyunwoo Park; Hyun Seok Song
Journal:  Int Orthop       Date:  2015-05-10       Impact factor: 3.075

Review 6.  [Primary radial head arthroplasty in trauma : Complications].

Authors:  K Schmidt-Horlohé; S Buschbeck; D Wincheringer; M Weißenberger; R Hoffmann
Journal:  Orthopade       Date:  2016-10       Impact factor: 1.087

7.  Tight-fitting radial head prosthesis: does stem size help prevent painful loosening?

Authors:  Pierre Laumonerie; Nicolas Reina; Claudia Gutierrez; Stephanie Delclaux; Meagan E Tibbo; Nicolas Bonnevialle; Pierre Mansat
Journal:  Int Orthop       Date:  2017-09-21       Impact factor: 3.075

8.  [Locking plate osteosynthesis of the radial head fractures : clinical and radiological results].

Authors:  K J Burkhart; D Gruszka; S Frohn; K Wegmann; P M Rommens; C M Eicker; L P Müller
Journal:  Unfallchirurg       Date:  2015-11       Impact factor: 1.000

9.  Radial head prosthesis in complex elbow dislocations: effect of oversizing and comparison with ORIF.

Authors:  Marc Schnetzke; Sara Aytac; Moritz Deuss; Stefan Studier-Fischer; Benedict Swartman; Matthias Muenzberg; Paul-Alfred Gruetzner; Thorsten Guehring
Journal:  Int Orthop       Date:  2014-08-02       Impact factor: 3.075

10.  Treatment of radial head and neck fractures: in favor of anatomical reconstruction.

Authors:  K J Burkhart; K Wegmann; J Dargel; C Ries; L P Mueller
Journal:  Eur J Trauma Emerg Surg       Date:  2012-09-13       Impact factor: 3.693

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.