Literature DB >> 16015246

A comparative study between proximal radial morphology and the floating radial head prosthesis.

Nebojsa Popovic1, Julien Djekic, Roger Lemaire, Philippe Gillet.   

Abstract

A morphometric study of the proximal radius was performed with computed tomography scanning in 51 healthy adults. These dimensions were then compared with those of a commercially available floating radial head prosthesis. Results were expressed as mean values, SD, and minimum and maximum values. The minimum and maximum diameters of the radial head were 21.9 +/- 1.9 mm and 22.9 +/- 1.9 mm, respectively. The minimum and maximum intramedullary diameters of the radial neck were 8.3 +/- 1.3 mm and 9.3 +/- 1.5 mm, respectively. The combined length of the radial head and neck was 22.47 +/- 2.84 mm. The implications for prosthetic design are as follows: the small floating cup (19 mm in diameter) is too small for the large majority of adults, the large floating cup (22 mm in diameter) is closer to the radial anatomy, the mean values are significantly different between male and female patients, and a single component would suffice for right and left elbows.

Entities:  

Mesh:

Year:  2005        PMID: 16015246     DOI: 10.1016/j.jse.2004.10.012

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  10 in total

1.  Morphometric parameters of the radial head: an anatomical study.

Authors:  T C Koslowsky; I Germund; F Beyer; K Mader; C F Krieglstein; J Koebke
Journal:  Surg Radiol Anat       Date:  2007-03-07       Impact factor: 1.246

2.  [Endoprosthetics of acute radial head fractures].

Authors:  K J Burkhart; K Wegmann; C Ries; L P Müller
Journal:  Unfallchirurg       Date:  2013-08       Impact factor: 1.000

3.  Simple overlay device for determining radial head and neck height.

Authors:  Jun-Gyu Moon; Richard D Southgate; James S Fitzsimmons; Shawn W O'Driscoll
Journal:  Skeletal Radiol       Date:  2010-03-01       Impact factor: 2.199

4.  Anthropometric study of the proximal radius: does radial head implant fit in all cases?

Authors:  Soo Hwan Kang; Dong Yeop Kim; Hyunwoo Park; Hyun Seok Song
Journal:  Int Orthop       Date:  2015-05-10       Impact factor: 3.075

5.  Causes for early and late surgical re-intervention after radial head arthroplasty.

Authors:  Pierre Laumonerie; David Ancelin; Nicolas Reina; Meagan E Tibbo; Panagiotis Kerezoudis; Stephanie Delclaux; Nicolas Bonnevialle; Pierre Mansat
Journal:  Int Orthop       Date:  2017-05-12       Impact factor: 3.075

6.  Beveled posteromedial corner of the radial head: a three-dimensional micro-computed tomography modeling study.

Authors:  Arnold Adikrishna; Young-Ho Shin; Rizki F Zulkarnain; Hanpyo Hong; Yucheng Sun; In-Ho Jeon
Journal:  J Anat       Date:  2017-08-15       Impact factor: 2.610

7.  [Locking plate osteosynthesis of the radial head fractures : clinical and radiological results].

Authors:  K J Burkhart; D Gruszka; S Frohn; K Wegmann; P M Rommens; C M Eicker; L P Müller
Journal:  Unfallchirurg       Date:  2015-11       Impact factor: 1.000

8.  Treatment of radial head and neck fractures: in favor of anatomical reconstruction.

Authors:  K J Burkhart; K Wegmann; J Dargel; C Ries; L P Mueller
Journal:  Eur J Trauma Emerg Surg       Date:  2012-09-13       Impact factor: 3.693

9.  Options and limits of angle stable plates in the treatment of comminuted radial head fractures.

Authors:  T F Raven; L Banken; J Doll; F Westhauser; B Reible; M Schönewald; G Schmidmaier; A Moghaddam
Journal:  J Orthop       Date:  2018-09-06

10.  Morphometric parameters of the radial neck: an anatomical study.

Authors:  T C Koslowsky; F Beyer; I Germund; K Mader; M Jergas; J Koebke
Journal:  Surg Radiol Anat       Date:  2007-05-10       Impact factor: 1.354