Respiration-averaged CT for attenuation correction in canine cardiac PET/CT.

Russell A H Cook1, Greg Carnes, Ting-Yim Lee, R Glenn Wells.   

Abstract

UNLABELLED: Heart disease is a leading cause of death in North America. With the increased availability of PET/CT scanners, CT is now commonly used as a transmission source for attenuation correction. Because of the differences in scan duration between PET and CT, respiration-induced motion can create inconsistencies between the PET and CT data and lead to incorrect attenuation correction and, thus, artifacts in the final reconstructed PET images. This study compared respiration-averaged CT and 4-dimensional (4D) CT for attenuation correction of cardiac PET in an in vivo canine model as a means of removing these inconsistencies.
METHODS: Five dogs underwent respiration-gated cardiac (18)F-FDG PET and 4D CT. The PET data were reconstructed with 3 methods of attenuation correction that differed only in the CT data used: The first method was single-phase CT at either end-expiration, end-inspiration, or the middle of a breathing cycle; the second was respiration-averaged CT, which is CT temporally averaged over the entire respiratory cycle; and the third was phase-matched CT, in which each PET phase is corrected with the matched phase from 4D CT. After reconstruction, the gated PET images were summed to produce an ungated image. Polar plots of the PET heart images were generated, and percentage differences were calculated with respect to the phase-matched correction for each dog. The difference maps were then averaged over the 5 dogs.
RESULTS: For single-phase CT correction at end-expiration, end-inspiration, and mid cycle, the maximum percentage differences were 11% +/- 4%, 7% +/- 3%, and 5% +/- 2%, respectively. Conversely, the maximum difference for attenuation correction with respiration-averaged CT data was only 1.6% +/- 0.7%.
CONCLUSION: Respiration-averaged CT correction produced a maximum percentage difference 7 times smaller than that obtained with end-expiration single-phase correction. This finding indicates that using respiration-averaged CT may accurately correct for attenuation on respiration-ungated cardiac PET.

Entities:  

Mesh:

Year:  2007        PMID: 17468434     DOI: 10.2967/jnumed.106.034199

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  16 in total

Review 1.  Quantification of myocardial blood flow and flow reserve: Technical aspects.

Authors:  Ran Klein; Rob S B Beanlands; Robert A deKemp
Journal:  J Nucl Cardiol       Date:  2010-08       Impact factor: 5.952

2.  The absolute (quantitative): dialogue between St. Thomas and Lord Kelvin: interview with Stephen L. Bacharach, as recorded by Luigi Mansi.

Authors:  Luigi Mansi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-09       Impact factor: 9.236

Review 3.  Current state of hybrid imaging: attenuation correction and fusion.

Authors:  Jonathon A Nye; Tracy L Faber
Journal:  J Nucl Cardiol       Date:  2011-05-07       Impact factor: 5.952

4.  Interpolated average CT for cardiac PET/CT attenuation correction.

Authors:  Greta S P Mok; Cobie Y T Ho; Bang-Hung Yang; Tung-Hsin Wu
Journal:  J Nucl Cardiol       Date:  2015-05-02       Impact factor: 5.952

5.  Automatic registration of misaligned CT attenuation correction maps in Rb-82 PET/CT improves detection of angiographically significant coronary artery disease.

Authors:  Piotr J Slomka; Mariana Diaz-Zamudio; Damini Dey; Manish Motwani; Yafim Brodov; David Choi; Sean Hayes; Louise Thomson; John Friedman; Guido Germano; Daniel Berman
Journal:  J Nucl Cardiol       Date:  2015-02-20       Impact factor: 5.952

6.  Techniques for respiration-induced artifacts reductions in thoracic PET/CT.

Authors:  Tao Sun; Greta S P Mok
Journal:  Quant Imaging Med Surg       Date:  2012-03

7.  Respiration-averaged CT for attenuation correction in non-small-cell lung cancer.

Authors:  Nai-Ming Cheng; Chih-Teng Yu; Kung-Chu Ho; Yi-Cheng Wu; Yuan-Chang Liu; Chih-Wei Wang; Tzu-Chen Yen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-12-03       Impact factor: 9.236

Review 8.  Advances in rubidium PET and integrated imaging with CT angiography.

Authors:  Mark F Smith
Journal:  Curr Cardiol Rep       Date:  2008-03       Impact factor: 2.931

Review 9.  Will 3-dimensional PET-CT enable the routine quantification of myocardial blood flow?

Authors:  Robert A deKemp; Keiichiro Yoshinaga; Rob S B Beanlands
Journal:  J Nucl Cardiol       Date:  2007 May-Jun       Impact factor: 5.952

10.  Computed tomography calcium score scan for attenuation correction of N-13 ammonia cardiac positron emission tomography: effect of respiratory phase and registration method.

Authors:  Habib Zaidi; Rene Nkoulou; Sarah Bond; Aylin Baskin; Thomas Schindler; Osman Ratib; Jerome Declerck
Journal:  Int J Cardiovasc Imaging       Date:  2013-03-17       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.