O A Catalano1, E Nicolai2, B R Rosen3, A Luongo4, M Catalano4, C Iannace5, A Guimaraes6, M G Vangel7, U Mahmood3, A Soricelli1, M Salvatore8. 1. Department of Radiology, University of Naples Parthenope -SDN IRCCS, Via F. Acton 38, Napoli, Na 80143, Italy. 2. Department of Nuclear Medicine, SDN IRCCS, Via Gianturco 113, Napoli, Na 80143, Italy. 3. Department of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard University Medical School, 149 Thirteenth Street, Charlestown, MA 02129, USA. 4. Department of Radiology, University of Naples 'Federico II', Naples, NA 80131, Italy. 5. Department of Surgery, Breast Unit, G. Moscati Hospital, Avellino, AV 83100, Italy. 6. Department of Radiology, Oregon Health and Sciences University, 3181 Southwest Sam Jackson Park Road, Portland, OR 97239, USA. 7. Department of Radiology, MGH Biostatistics Center and MGH Martinos Center, Harvard University Medical School, 149 Thirteenth Street, Charlestown, MA 02129, USA. 8. Department of Radiology and of Nuclear Medicine, SDN IRCCS, Via Gianturco 113, Napoli, Na 80143, Italy.
Abstract
BACKGROUND: Despite improvements in treatments, metastatic breast cancer remains difficult to cure. Bones constitute the most common site of first-time recurrence, occurring in 40-75% of cases. Therefore, evaluation for possible osseous metastases is crucial. Technetium 99 ((99)Tc) bone scintigraphy and fluorodexossyglucose (FDG) positron emission tomography (PET)-computed tomography (PET-CT) are the most commonly used techniques to assess osseous metastasis. PET magnetic resonance (PET-MR) imaging is an innovative technique still under investigation. We compared the capability of PET-MR to that of same-day PET-CT to assess osseous metastases in patients with breast cancer. METHODS: One hundred and nine patients with breast cancer, who underwent same-day contrast enhanced (CE)-PET-CT and CE-PET-MR, were evaluated. CE-PET-CT and CE-PET-MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Binomial confidence intervals and a χ(2) test were used for categorical data, and paired t-test was used for the SUVmax data; a non-informative prior Bayesian approach was used to estimate and compare the specificities. RESULTS: Osseous metastases affected 25 out 109 patients. Metastases were demonstrated by CE-PET-CT in 22 out of 25 patients (88%±7%), and by CE-PET-MR in 25 out of 25 patients (100%). CE-PET-CT revealed 90 osseous metastases and CE-PET-MR revealed 141 osseous metastases (P<0.001). The estimated sensitivity of CE-PET-CT and CE-PET-MR were 0.8519 and 0.9630, respectively. The estimated specificity for CE-FDG-PET-MR was 0.9884. The specificity of CE-PET-CT cannot be determined from patient-level data, because CE-PET-CT yielded a false-positive lesion in a patient who also had other, true metastases. CONCLUSIONS: CE-PET-MR detected a higher number of osseous metastases than did same-day CE-PET-CT, and was positive for 12% of the patients deemed osseous metastasis-negative on the basis of CE-PET-CT.
BACKGROUND: Despite improvements in treatments, metastatic breast cancer remains difficult to cure. Bones constitute the most common site of first-time recurrence, occurring in 40-75% of cases. Therefore, evaluation for possible osseous metastases is crucial. Technetium 99 ((99)Tc) bone scintigraphy and fluorodexossyglucose (FDG) positron emission tomography (PET)-computed tomography (PET-CT) are the most commonly used techniques to assess osseous metastasis. PET magnetic resonance (PET-MR) imaging is an innovative technique still under investigation. We compared the capability of PET-MR to that of same-day PET-CT to assess osseous metastases in patients with breast cancer. METHODS: One hundred and nine patients with breast cancer, who underwent same-day contrast enhanced (CE)-PET-CT and CE-PET-MR, were evaluated. CE-PET-CT and CE-PET-MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Binomial confidence intervals and a χ(2) test were used for categorical data, and paired t-test was used for the SUVmax data; a non-informative prior Bayesian approach was used to estimate and compare the specificities. RESULTS:Osseous metastases affected 25 out 109 patients. Metastases were demonstrated by CE-PET-CT in 22 out of 25 patients (88%±7%), and by CE-PET-MR in 25 out of 25 patients (100%). CE-PET-CT revealed 90 osseous metastases and CE-PET-MR revealed 141 osseous metastases (P<0.001). The estimated sensitivity of CE-PET-CT and CE-PET-MR were 0.8519 and 0.9630, respectively. The estimated specificity for CE-FDG-PET-MR was 0.9884. The specificity of CE-PET-CT cannot be determined from patient-level data, because CE-PET-CT yielded a false-positive lesion in a patient who also had other, true metastases. CONCLUSIONS: CE-PET-MR detected a higher number of osseous metastases than did same-day CE-PET-CT, and was positive for 12% of the patients deemed osseous metastasis-negative on the basis of CE-PET-CT.
Despite improvements in treatments, metastatic breast cancer remains difficult to cure, with a median survival of 2–3 years and an estimated 10-year survival rate of approximately 10% (Wood ). Among the metastatic organs, bones constitute the most common site of first-time recurrence, occurring in 40–75% of cases (Wood ). Careful evaluation for possible bony metastases is therefore crucial. Technetium 99 (99mTc) MDP bone scintigraphy and fluorodexossyglucose (FDG) positron emission tomography-computed tomography (PET-CT) are the most commonly used techniques to assess for bony metastasis in breast cancerpatients, with reported sensitivity, specificity and accuracy of 67–95.2%, 80.9–96% and 60–80.3% for 99mTc MDP bone scintigraphy and 77.7–96%, 88.2–99% and 92.1–94.1% for FDG-PET-CT (Ohta ; Gallowitsch ; Hahn ; Houssami and Costelloe, 2012; Rong ).However, other techniques have also been employed for the same purpose, including whole-body diffusion weighted magnetic resonance (MR) imaging (WB-DWI) alone or as part of a more comprehensive WB magnetic resonance examination, with reported sensitivity, specificity and accuracy of 86, 8, 35% for WB-DWI alone in a selected breast cancer population, with sensitivity and specificity of 33–91% and 99% for WB-DWI alone in a mixed population of bony metastases from breast and prostate cancers, and with sensitivity, specificity and accuracy of 88–96.5%, 90–100% and 91% for WB magnetic resonance examination (Engelhard ; Costelloe ; Gutzeit ; Heusner ). PET magnetic resonance (PET-MR) imaging is an innovative technique whose potential benefits and limitations are still under investigation. In our study, we compared the performance of FDG-PET-CT and FDG-PET-MR in the assessment of bony metastases in a cohort of breast cancerpatients.
Materials and Methods
Patient enrolment
This Health Insurance Portability and Accountability Act–compliant retrospective study was approved by the institutional review board. Patients gave written informed consent for study enrolment before undergoing PET-MR. The authors had full control of the data and information submitted for publication. At our institution, as required by the institutional review board and by the Minister of Health, PET-MR can be performed only in patients undergoing same-day PET-CT with the same radioactivity as required for a standalone PET-CT.Consecutive treated and untreated invasive ductal breast cancerpatients who underwent same-day contrast enhanced (CE)-FDG-PET-CT and CE-FDG-PET-MR were evaluated for inclusion in this retrospective study. In cases where there were multiple PET-CT and PET-MR exams for the same patient, the first retrievable study was evaluated. Inclusion criteria were: (a) invasive ductal breast cancer, (b) ≥18 years of age, (c) same-day CE-FDG-PET-CT and CE-FDG-PET-MR, (d) less than 180 min elapsed between FDG injection and PET-MR imaging and (e) availability of comparative imaging including prior exams and/or follow-ups. Exclusion criteria were: (a) pregnancy, (b) blood glucose levels >140 mg dl−1 (7.77 mmol l−1), (c) inadequate PET-CT images, PET-MR images or both, (d) MR contraindications and (e) occurrence of too many lesions to count (>25) to exclude confluent lesions.
Financial support
Although we received no financial support, two authors (BRR and ARG) are consultants for Siemens Healthcare (Erlangen, Germany). Like all other authors, they had access to the data and control of the information.
PET-CT protocols
Patients fasted for at least 6 h before imaging. Blood glucose levels were assessed before imaging. PET-CT was started a mean of 60±10 min after injection of FDG (mean dose±s.d., 4.44 MBq per kg of body weight±1; range, 370–400 MBq). Images were acquired with 64-detector row PET-CT scanners (Gemini TF; Philips, Best, the Netherlands) with time-of-flight capabilities. PET-CT was performed at full image quality from mid-thighs to the cranial vault, without and with contrast injection, according to the manufacturer technical protocols. Total acquisition time was 18±9 min. Technical details of the CE-FDG-PET-CT protocol are outlined in Table 1.
PET data and CT attenuation scans were acquired during shallow free breathing. PET data underwent automatic attenuation correction using attenuation maps generated from attenuation correction CT. Diagnostic non-contrast-enhanced and diagnostic contrast-enhanced scans were acquired during shallow free breathing for the head, neck, pelvis and upper thighs; they were acquired during breath-hold in expiration for the chest and upper abdomen. All patients underwent contrast injection. Iodine-based contrast medium Iomeprol (Iopamiro 370, Bracco Imaging S.p.A., Milan, Italy) was injected intravenously with a power injector (Empower CTA, Acist Medical Solutions, Eden Prairie, MN, USA) at 2 ml s−1, at a fixed dose of 80 ml for patients weighing <80 kg and at 100 ml for those weighing ≥80 kg; scans were started at the end of contrast injection.
PET-MR protocols
PET-MR was performed with a Biograph mMR imager (Siemens Healthcare, Erlangen, Germany) with a 16-channel head-neck coil and three or four 12-channel body coils depending on patient's height. These coils were combined into a multichannel whole-body coil by using total imaging matrix technology. PET-MR imaging began 125.8±25.74 min after FDG injection. Our protocols start with basic co-acquired non-CE (NCE)-MR pulse sequences performed in every patient in conjunction with PET from mid-thighs to the cranial vault. Thereafter, if the patient had not undergone breast surgery, we chose a dedicated ‘non-operated breast protocol' that includes dynamic breast sequences, followed by whole-body CE axial and coronal T1-weighted sequences. If breast surgery had already been performed, we opted for an ‘operated breast protocol' that includes upper abdominal dynamic sequences as well as whole-body CE axial and coronal T1-weighted sequences.The dedicated dynamic breast and upper abdominal sequences were not evaluated, and therefore are not described. The whole-body CE axial and coronal T1-weighted sequences were evaluated. The relevant technical details of the NCE and CE PET-MR acquisitions, which were performed in accordance with the manufacturer technical protocols, are reported in Table 2. Accordingly, in our patient population, only the basic NCE-FDG-PET-MR sequences, including the DWI (axial T2-weighted HASTE, axial PET, axial fused HASTE-PET, axial b-800 DWI, ADC map, coronal STIR, coronal T1 in-phase and out-of-phase Dixon) and the whole-body CE axial and coronal T1-weighted sequences were analysed. Mean total time for the PET-MR examination was 100.97±21.43 min. Mean total time for PET-MR was 107.87±18.92 min in the case of dedicated breast dynamic sequences; otherwise it lasted 94.07±25.45 min. All the patients were able to tolerate well the whole study.
Table 2
Technical details of the CE-FDG-PET-MR
MR sequence
Plane
Area scanned
iPat
TR (ms)
TE (ms)
Matrix
NEX
FOV (mm)
Thickness (mm)
Gap (mm)
FA (degrees)
Voxel size (mm)
TI (ms)
Fat saturation
Co-aquired with PET
T1w 2-Point Dixon VIBE
Coronal
Whole body
2
3.6
1st TE 1.225
2nd TE 2.45
79 × 192
1
500
3.1
0
100
4.1 × 2.6 × 3.1
STIR
Coronal
Whole body
3
4482–5631
81–87
186 × 384
1
450
5.0
1.5
1.6 × 1.2 × 5.0
220–230
DWI (b-values 50–400–800)
Axial
Whole body
2
9100–18 800
66–83
112 × 156
2
420
6.0
0.6
2.7 × 2.7 × 6.0
220
T2w HASTE
Axial
Whole body
2
1400
86–97
288 × 384
1
380
6.0
0.6
1.3 × 1.0 × 6.0
Whole-body contrast-enhanced sequences acquired after PET
T1w VIBE
Coronal
Whole body
3
2.54–4.06
1.14–1.91
248 × 288
1
400
3.0
0
9o
1.4 × 1.4 × 1.5
Quick spectral fat saturation
T1w VIBE
Axial
Whole body
2
4.06–4.1
1.81–1.91
180 × 230
1
380
3.0
0
9o
1.6 × 1.2 × 3.0
Quick spectral fat saturation
Abbreviations: AW OSEM 3D=three-dimensional attenuation weighted ordered subsets expectation maximisation iterative reconstruction algorithm; BP=bed position; CE-FDG-PET-CT=contrast enhanced-fluorodexossyglucose-positron emission tomography-computed tomography; DWI=diffusion weighted imaging; FA=flip angle; FOV=field of view; FS=fat saturated; FSE=fast spin echo; GE=gradient echo; HASTE=half Fourier single shot fast spin echo T2-weighted; iPat=integrated parallel acquisition technique; MR, magnetic resonance; SPAIR=spectral adiabatic inversion recovery; STIR=short tau inversion recovery; TE=time of echo; TI=time of inversion; TR=time of repetition; VIBE=volume interpolated breath hold T1 weighted.
PET images were co-acquired with MR sequences, starting from the mid thighs and moving towards the head. BP in the thighs, pelvis and neck were acquired during shallow free breathing, while, in the upper abdomen and thorax, they were acquired during expiratory breath-hold. PET data underwent automatic attenuation correction using attenuation maps generated from the 2-point Dixon sequence. The reconstruction software automatically corrects for the delay between the time of FDG injection and the time of PET data acquisition for each bed position.
0.1 mmol kg−1 (0.5 mmol ml−1) of Gadopentate dimeglumine (Gd-DTPA; Magnevist, Bayer Pharma AG, Berlin, Germany) were injected in an antecubital vein at 3 ml s−1 followed by the same volume of saline at 3 ml s−1 using a power injector (Spectris Solaris EP, Medrad, Warrendale, PA, USA) and dedicated breast or upper abdominal dynamic protocols were run. The technical details of the breast and of the dynamic upper abdominal sequences are not described in the current table because the corresponding images were not evaluated in the present study. We describe the VIBE axial and coronal sequences used to cover the whole body at the end of the breast or upper abdominal dynamic protocols.
Image registration and fusion
To be consistent with the manufacturers' indications and with the typical clinical scenarios, the hybrid studies were assessed with the workstations recommended by each of the manufacturers. Therefore, PET-CT images were co-registered, fused by and evaluated at a dedicated workstation (Extended Brilliance Workstation; Philips) and a picture archiving and communication system (IDS7; Sectra, Linkoping, Sweden); whereas PET-MR images were fused by and evaluated at a dedicated workstation (Syngo.via; Siemens Healthcare, Erlangen, Germany) and the aforementioned picture archiving and communication system.
Image evaluation
Two radiology residents (AL and MC) searched our breast cancer database and selected patients who satisfied the enrolment and exclusion criteria. For each case, they uploaded the PET-CT or PET-MR images at random. The images were then evaluated by consensus of two readers (a radiologist (OAC) and a nuclear medicine physician (EN) with 14 and 26 years of experience, respectively).Each hybrid study was evaluated as a whole. When assessing the PET-CT images, the readers simultaneously evaluated the CT images in bone and soft tissue windows, the PET images and the fused PET-CT images. The readers were allowed to modify the window settings as needed. If the readers were assessing the PET-MR images, they simultaneously evaluated the axial T2-weighted HASTE, axial PET, axial fused HASTE-PET, axial b-800 DWI, ADC map, coronal STIR, coronal T1 in-phase and out-of-phase Dixon, and axial and coronal post-contrast T1-weighted VIBE. A separate evaluation of whole-body b-800 DWI (WB-DWI) to be compared with PET-CT was also performed.The readers evaluated only one type of study at a time, either the PET-CT or PET-MR or WB-DWI, for each patient; the remainder of the study was analysed at least 6 weeks later to reduce recall bias. After completion of the PET-CT and PET-MR evaluation, the two readers compared the PET-CT and the PET-MR and the WB-DWI findings and correlation with prior and/or follow-up studies was performed. Readers were aware only of the clinical history of breast cancer. They specifically looked for:Presence or absence of bony metastasisNumber of metastasesLocation (appendicular skeleton, vertebrae, pelvic bones, skull, ribs, sternum)Imaging appearance (lytic, sclerotic, mixed lytic and sclerotic and permeative)SizeSUVmax of the five most FDG-avid metastases in each patient.For both PET-CT and PET-MR imaging, accepted published imaging criteria were used to evaluate for metastasis. Specifically, the following criteria were considered consistent with malignancy: on CT, the occurrence of lytic, sclerotic, mixed sclerotic-lytic changes and/or bone changes with associated soft tissue abnormalities; on MR, focal or diffuse bone marrow intermediate or high signal intensity (SI) on T2-weighted images, STIR, DWI, associated with low SI compared with muscles on T1-weighted sequences, or focal or diffuse areas of persistent low SI on all sequences, ‘bull's eye', ‘halo sign', extra-osseous tumour infiltration, enhancement after Gadolinium administration, SI changes extending into the pedicles and bulging of the posterior and/or anterior margin of the vertebral bodies, ADC values <1.2 × 10−3 mm2 s−1; on PET, a focally increased FDG-uptake not associated with significant signs of infection, trauma, degenerative processes, and in equivocal cases an SUV>2.5. For WB-DWI only, areas of focal, multifocal or diffuse, irregular high SI within background suppressed bone marrow SI was considered consistent with malignancy.The following criteria were considered consistent with benignity: on CT location along vertebral endplates, posterior aspect of the spinous process, and along the facets joint, on MR high SI on T1-weighted sequences, location along degenerative changes and/or along joints, drop of at least a 20% of SI on out of phase T1-weighted sequences relative to in phase T1-weighted sequences, absence of enhancement, and finally on PET absence of focally increased FDG-uptake (Rybak and Rosenthal, 2001; Schmidt ; Kim ; Messiou ; Padhani and Gogbashian, 2011).The classification of the imaging appearance of the lesions was mainly derived from CT, in particular, in the case of lytic, sclerotic and mixed lytic and sclerotic; whereas it was mainly derived from MR in the case of permeative lesions. In the case of discordances between PET-CT and PET-MR, the referring oncologist was consulted to find out if they had impacted on patient's management.
Reference standard
Correlations with prior imaging and follow-up studies were used as the reference standard. For these patients, we used either appearance of a new bony lesion that satisfied imaging criteria for malignancy and that was absent in the prior studies, increased 99Tc uptake, increased lesion size or increased FDG uptake, or decreased size and decreased FDG uptake after chemotherapy or radiation therapy as confirmation criteria. A case was considered negative when no lesions were identified on both PET-CT and PET-MR and the follow-ups did not disclose any detectable lesions (follow-up length range 347–621 days).
Statistical methods
Results are stated as means plus or minus one standard deviation. Except as noted below, binomial confidence intervals (using the normal approximation) and a χ2 test were used for categorical data, and a paired t-test was used for the SUVmax data. We used a non-informative prior Bayesian approach (Box and Tiao, 1973) to estimate and compare the sensitivities of PET-MR and PET-CT. We selected this approach, in part, because PET-MR was ‘perfect' for detecting metastases in all patients who had them, with no false positives. For this situation, the more typical frequentist approach to data analysis breaks down. We assumed binomial likelihoods for the probability of detecting bony metastases, with uniform priors on the binomial parameters. For patients who had metastases, the parameter of the binomial distribution is the sensitivity. For patients who did not have metastases, the binomial parameter is one minus the specificity. We summarised the results with posterior means and equal-tail 95% credible intervals. We also estimated the probability of PET-MR having higher sensitivity than PET-CT using numerical integrations involving the posterior distributions of the binomial parameters.
Results
A total of 168 breast cancerpatients underwent same-day PET-CT and PET-MR between 1 March 2013 and 28 February 2014. In all, 59 patients were excluded: 2 because of severe ferromagnetic MR artefacts due to the breast tissue expanders that partially obscured the lower chest and upper abdomen, 49 due to absence of prior and/or follow-up imaging and 8 because of innumerable bony metastases. Our final study population comprised 109 patients (all women; mean age=58.08±10.74 years). Of the 109 breast cancerpatients who satisfied the inclusion criteria, 51 patients, not having undergone breast surgery, underwent dynamic evaluation of the breast during the PET-MR study, meanwhile 58 patients, because of previous breast surgery, underwent dynamic liver assessment during their PET-MR study.In all, 23 patients had only prior imaging (23 out of 23 patients had 99Tc uptake, 23 out of 23 had CT, 1 out of 23 had MR, 20 out of 23 had PET-CT) acquired (mean±s.d.) 1354±903.11 days, range 354–3278 days, before. A total of 27 patients had only follow-ups (20 out of 27 patients had 99Tc uptake, 27 out of 27 had CT, 3 out of 27 had MR, 23 out of 27 had PET-CT, 23 out of 27 had PET-MR) acquired 449.14±88.75 days, range 347–630 days, after; and 59 patients had both prior imaging (47 out of 59 patients had 99Tc uptake, 59 out of 59 had CT, 8 out of 59 had MR, 49 out of 59 had PET-CT) performed 1578.43±1003.49 days, range 394–3167 days, before as well as follow-ups acquired 516.94±88.68 days, range 358–621 days, after the imaging study under analysis (32 out of 59 patients had 99Tc uptake, 59 out of 59 had CT, 2 out of 59 had MR, 59 out of 59 had PET-CT, 59 out of 59 had PET-MR). Bony metastases were found in 25 patients (23±4%): 9 out of 25 for staging of non-operated breast cancer and 16 out of 25 for restaging of operated breast cancer.All PET-MR examinations were performed after PET-CT examinations and within 180 min after FDG injection (mean, 125.8±25.74 min). Overall, bony metastases were detected by PET-CT in 22 out of 25 (88±7%) patients and by PET-MR in 25 out of 25 (100%) patients. All lesions detected by both PET-CT and PET-MR were true malignancies, except for one case for which the only candidate lesion detected by PET-CT was actually benign and for two other cases with metastases for which PET-CT detected no lesions. The following results are for true-positive detections only; hence for both PET-CT and PET-MR, the number of cases is 25, but for 3 cases the number of PET-CT lesions is zero.In a patient-to-patient comparison, PET-CT and PET-MR findings were concordant in detecting bony metastases in 22 out of 25 (88±7%) patients, and discordant in 3 out of 25 (12±7%) patients. With respect to the discordant cases, bony metastases were found with PET-MR but not with PET-CT in 3 out of 25 (12±7%) patients; moreover, in one patient, a benign area of sclerosis was misinterpreted as metastasis on the CT part of the PET-CT. In a lesion-to-lesion comparison, PET-CT detected 90 bony metastases: 51 out of 90 (57±5%) on both PET and CT, 37 out of 90 (41±5%) only on PET without corresponding anatomic correlates and 2 out of 90 (2±2%) only on CT. Of the 53 metastases visible on CT, 41 were lytic, 9 sclerotic and 3 mixed. One sclerotic and one lytic metastasis were visible only on CT and missed on PET not being FDG avid at the time of the study.PET-MR detected 141 bony metastases: 85 out of 141 (60±4%) both on PET and MR, 5 out of 141 (4±2%) on PET only and 51 out of 141 (36±4%) on MR only. Overall, MR showed 136 out of 141 (96±2%) metastases (56 lytic, 9 sclerotic, 3 mixed and 68 permeative). Significantly more lesions were detected using PET-MR than with PET-CT (P<0.001). Within the 25 patients with bony metastases, WB-DWI detected 131 bony lesions: 117 true positive metastases (in 24 patients), 14 false positive metastases (in 8 patients), 19 false negative metastases (in 9 patients, 1 of which was deemed free from his single bony metastasis based on WB-DWI).When we further evaluated the data subdivided according to CT alone, PET-CT, PET-MR, MR and WB-DWI, we found that more lesions were detected by PET-CT than by CT alone and by PET-MR than by MR alone for the 22 cases, for which both PET-CT and PET-MR had true-positive results (88±6%). For each of the remaining three cases, a single lesion was detected by both PET-MR and by MR alone, and no lesions were detected correctly by PET-CT. Based on 22 cases, the mean number of additional lesions detected by PETCT as compared with CT alone was 4.0±4.8, and the mean number of additional lesions detected by PET-MR as compared with MR alone was 3.6±4.7. More lesions were detected by MR alone than by CT alone in 14 cases (56±10%), and the number of additional lesions detected by MR alone was 3.5±4.5. Both MR alone and CT alone detected no lesions for the remaining 11 cases.We subsequently compared true-positive PET-CT, PET-MR and DWI lesion counts. There was one patient with no lesions detected by DWI (and one lesions detected by each of PET-MR and PET-CT), and eight cases with some false-positives DWI lesions (32±9%). More lesions were detected by PET-CT than by DWI for 4 cases (16±7%), with the same number of lesions (all non-zero) detected for 11 cases (44±10%). More lesions were detected by PET-MR than by DWI for 9 cases (36±10%), with the same number of lesions detected for 16 (64±10%) cases. Lesion locations on PET-CT and on PET-MR are described in Table 3. The locations did not differ significantly between the two modalities (P=0.83). Lesion size was 17.69±12.64 mm, range 5–54 mm, for all the metastases visible on CT, 13.17±10.73 mm, range 5–54 mm, for all those visible on MR and 12.94±4.66 mm, range 6–28 mm, for those visible only on MR and not visible on CT. The size did not differ significantly between PET-CT and PET-MR (P=1.77). SUVmax for PET-CT was 5.00±3.14, SUVmax for PET-MR was 5.95±4.14, and the difference in means was −1.48±2.37. This difference in means is highly significant (P<0.00001).
Table 3
Locations of bone metastases on CE-FDG-PET-CT vs CE-FDG-PET-MR
No statistically significant differences were found between locations of bone metastases on CE-FDG-PET-CT vs CE-FDG-PET-MR. Most of the bone metastases affected the spine and pelvic bones.
For PET-MR, at least some of the metastases were detected for all 25 patients with bony metastases, whereas there were no false-positives for any of the 84 patients without bony metastases. For PET-CT, at least some of the metastases were detected for 22 of the 25 patients with bony metastases. One of the patients with bony metastases was positive for benign tissue only; we consider this patient as a false-negative for the purpose of sensitivity calculation.We estimate the sensitivity of PET-CT and PET-MR, respectively, to be 0.8519 with 95% credible interval (0.6985, 0.9564) and 0.9630 with 95% credible interval (0.8677, 0.9990). We estimate the probability that PET-MR has higher sensitivity than PET-CT for detecting bony metastases to be 0.95. The specificity for PET-MR is estimated to be 0.9884 with 95% credible interval (0.9575, 0.9997). The specificity of PET-CT cannot be determined from patient-level data, because CE-FDG-PET-CT yielded a false-positive in a patient who also had metastases. In the 22 out of 25 patients whose PET-CT was positive for bony metastases, no change in the management was induced by detecting more metastases on the same-day PET-MR imaging study. However, in the 3 out of 25 patients, who had already undergone treatments in the past and were considered disease free at the time of their PET-MR, the demonstration on PET-MR only of bony metastases prompted start of radiation therapy and change in hormone therapy in 2, and initiation of chemotherapy in 1.
Discussion
We describe our early experience with PET-MR in the detection of bony metastases, based upon a heterogeneous population of breast cancerpatients referred for PET-CT. PET-CT is considered pivotal in oncologic management and has been shown to provide more accurate TNM staging than CT or PET alone in several cancers (Antoch ; Lardinois ; Johnson and Branstetter, 2014). Although PET-CT is increasingly utilised, PET-MR for breast cancer staging has not been evaluated in a clinical setting. PET-CT is not routinely indicated in operable stages I, II and III, or in locally advanced invasive breast cancer stages IIIA, IIIB, IIIC, or even in stage IV disease. The National Comprehensive Cancer Network (NCCN) recommends against using PET-CT in early-stage breast cancer. According to the NCCN guidelines (NCCN guidelines 3.2014), 99Tc scintigraphy or Na-Fluoride-PET-CT are the modality of choice to search for bony metastases in breast cancerpatients before treatment, when a systemic staging is being contemplated. PET-CT is deemed ‘optional' and ‘most helpful when standard staging studies are equivocal or suspicious, especially in the settings of locally advanced or metastatic disease.' The same recommendations apply for follow-up during and after treatment. Bone scans can be omitted when PET-CT is positive for bone metastases.However, PET-CT is limited by the low-intrinsic tissue contrast of CT, which renders difficulty in the detection of subtle lytic or permeative metastases, and by the degree of glycolytic metabolism. FDG-avid neoplasms need to have a sufficient metabolic activity to be detected by PET (Mueller-Lisse ; Ozawa ; Sharma ). The soft tissue and contrast resolution of MR can help detect lesions and delineate anatomy more clearly than CT (von Schulthess and Schlemmer, 2009; Boss ). However, lesion size, location, MR spatial resolution and artefacts may hamper MR performance. MR additionally allows ‘functional' evaluation such as with DWI, which provides an alternate contrast mechanism that can be used as a whole-body screening technique to search even for lesions <10 mm (Nasu ; Padhani ). In our study, we compared PET-CT with same-day PET-MR for evaluation of bony metastases in breast cancerpatients of several stages, irrespective of NCCN guidelines.PET-MR showed bony metastases in more patients (25 on PET-MR and 22 on PET-CT) and overall more lesions (141 metastases on PET-MR and 90 on PET-CT) than PET-CT. In our population, we found PET-MR potentially able to overcome some of the limitations of PET-CT and MR alone (Figures 1, 2, 3, 4, 5). According to our experience, and in agreement with data from other studies, PET-MR might be more useful than PET-CT in the evaluation of bony lesions (Catalano ). On PET-MR, the concordance of increased FDG uptake with high SI on STIR, lack of a drop in SI on out-of-phase Dixon images and bright contrast enhancement were all suggestive of malignancy (Taoka ; Hwang, 2008; Costelloe ).
Figure 1
Coronal reformatted CT (A), coronal PET from PET-CT (B), fused coronal PET-CT (C), coronal STIR (D), coronal PET from PET-MR (E), fused coronal PET-MR (F). Two FDG-avid left iliac bony metastases (arrows) can be observed in the PET images obtained from both the PET-CT and the PET-MR scanner. However, no anatomic correlates are visible on CT, whereas they are clearly visible in the STIR image.
Figure 2
Axial CT (A), axial PET from PET-CT (B), fused axial PET-CT (C), axial HASTE (D), axial PET from PET-MR (E), fused axial PET-MR (F). A large sclerotic FDG-avid vertebral metastasis is identified on CT (arrow) as well as in the corresponding PET image. The reduced signal intensity on same-level HASTE images (D) makes the lesion visible on the MR image as well.
Figure 3
Axial CT (A), axial PET from PET-CT (B), fused axial PET-CT (C), axial contrast-enhanced VIBE (D), axial PET from PET-MR (E), fused axial PET-MR (F). A lytic FDG-avid left rib metastasis, with destruction of the bony marrow and thinning of the cortex, is indicated by arrow in the PET-CT images. The metastasis is also well seen on same-level PET-MR because of the contrast enhancement observed in the VIBE image, as well as to the increased FDG uptake. Please note increased left costo-vertebral junction uptake on PET-MR due to arthritis. The position of the arms along the body during PET-MR acquisition, and beyond the head during PET-CT scanning, explains the concurrent visibility of the primary breast cancer (red arrow) on PET-CT only.
Figure 4
Axial CT (A), axial PET from PET-CT (B), fused axial PET-CT (C), axial contrast-enhanced VIBE (D), axial PET from PET-MR (E), fused axial PET-MR (F), axial 800 No lesions are identified on the PET-CT examination. However, an area of intense enhancement (arrow in D) with corresponding restricted diffusion (G, H) and increased signal on STIR (I) is appreciated in the manubrium sterni. The lesion, corresponding to a permeative bony metastasis, is devoid of FDG activity.
Figure 5
Coronal STIR (A), coronal PET from PET-MR (B), fused coronal PET-STIR (C), coronal contrast-enhanced VIBE (D), coronal fused PET-contrast-enhanced VIBE (E) and axial 800 A focal area of marked FDG uptake, corresponding to a bony metastasis, is identified within the left vertebral body of D10 (arrow in B, C, E). No lesions are identified on the corresponding MR images.
PET and MR can work synergistically to increase the overall diagnostic yield. Not only can MR provide an anatomic correlate for FDG-avid lesions without a definite corresponding CT alteration (Figure 1), it might also be able to detect bony metastases with low FDG uptake that are invisible on PET-CT. These lesions might show high water content on PET-MR, presenting as small lytic or permeative bony lesions. Moreover, the intense enhancement after Gadolinium may increase the diagnostic confidence of the reader (Figure 4; Costelloe ). On the other hand, PET can show highly metabolic lesions whose MR correlate might be missed by MR alone, particularly if small (Figure 5). In our population, the fused PET-MR reading helps explain why most of the FDG-avid lesions had a corresponding MR abnormality.In our initial experience, PET-MR is not inferior to PET-CT in detecting sclerotic bony lesions. They may present low FDG uptake, and might be difficult to see on PET; however, they are hypointense on T1-weighted Dixon and hypointense on T2-weighted HASTE images. They may present hypointense with adjacent hyperintensity on STIR, and may enhance after Gadolinium. There were no patients who showed bony metastases on PET-CT who did not show bony metastases on PET-MR. In contrast, three patients with no visible bony metastases on PET-CT showed bony metastases on PET-MR. Therefore, we estimate the probability that PET-MR is indeed more sensitive than PET-CT to be 0.95.PET-MR detected 141 metastases, whereas PET-CT detected 90 metastases. Of the 51 metastases observed on PET-MR and not on PET-CT, 49 were observed on MR only (5 lytic and 44 permeative) and 2 on both PET and MR (2 permeative). The PET visibility of 2 more metastases on PET-MR compared with the negative FDG uptake on the PET-CT might be related to the delayed acquisition of PET-MR compared with PET-CT with reduced background uptake and increased lesion visibility.WB-DWI detected 131 bony lesions that were interpreted as metastases; of these 117 were true positives and 14 false positives due to benign bony changes (osteoarthritis, vertebral haemangiomas, osseous infarctions and isolated bone marrow islands) and to magnetic field inhomogeneities due to air interfaces. WB-DWI missed 19 metastases visible on the other MR sequences: 9 because of their sclerotic nature and 10 (8 lytic plus 2 permeative) due to inappropriate fat suppression at the thoracic inlet/neck region with associated chemical shift artefacts, and due to motion as well as air magnetic susceptibility artefacts. Of these 19 bony metastases not visible on WB-DWI but visible on other MR sequences, 10 were FDG avid (2 sclerotic, 7 lytic and 1 permeative). WB-DWI did not pick up the five metastases visible only on PET and not on MR. The high sensitivity and intermediate to low specificity of WB-DWI that we experienced is in agreement with previous studies; to improve WB-DWI performance, it should be interpreted, as we did in the joined evaluation of all our PET-MR sequences, along with conventional MR sequences and with ADC maps, and in the case of PET-MR, with the associated PET data (Wu ; Lecouvet ). In our experience, the increased sensitivity of WB-DWI has a reduced specificity when compared with PET-CT that makes it less beneficial.On PET-CT in two patients, no bony lesions were found with potential under-staging; in one other patient, a benign area of sclerosis was misinterpreted as metastases and a permeative bony metastases was not detected. These three patients did not have other metastases at the time of the scanning. In these 3 out of 25 patients, management was directly impacted by PET-MR. The two patients whose PET-CT was read negative underwent radiation therapy on their single bony metastases and change in the hormonal therapy; in the latter patient, chemotherapy was introduced and she presented progression at the 6-month follow-up. Our experience is in agreement with that of Souvatsoglou who found, using a different tracer than ours, 11C-Choline-PET-MR to be better than 11C-Choline-PET-CT in anatomical allocation of bony metastasis from prostate cancer (Souvatzoglou ).When we correlated the SUVmax from FDG-PET-CT with that from PET-MR, differently than in other papers, the SUV from PET-MR (5.95±4.14) was slightly higher than that from PET-CT (5±3.14) (Eiber ). This discrepancy might be related, at least in part, to the time between the two scans (58.24±15.17 min). However, all of the lesions that were FDG avid in the PET-CT study were also avid in the PET-MR study. Two lesions, whose FDG uptake was pathologic with PET-MR being prominent against absent background activity and with SUVmax 2.53 and 2.73, respectively, were undetectable on PET-CT due to similar FDG uptake as adjacent normal bone.Our approach to PET-MR has been to use both MR and PET to their full potential, and together, similar to the approach by Stolzman for lung nodules, and by others for whole-body oncologic evaluation (Catalano ; Stolzmann ). Our results are similar to those from Beiderwellen who identified 100% of bony metastases from different primaries using PET-MR (Beiderwellen ). Differently from the approach by Eiber, who used only Dixon and T1-weighted FSE, we used more sequences, reflecting the current clinical MR protocols (Eiber ).Our study has several limitations. First, PET-MR constitutes an innovative technique for which experience and consensus regarding imaging protocols is lacking. Another limitation is the lack of a pathological reference standard, related to the difficulty in performing image-guided bone biopsy for lesions that are invisible on CT. Therefore, in our retrospective study, we relied on prior imaging and/or follow-up for reference standard. Finally, there is a potential selection bias introduced by the retrospective nature of the study and by its being based on referral.As per recommendations of the European Association of Nuclear Medicine, our Institutional Review Board requested that PET-CT to be acquired 60 min after FDG administration. Therefore, PET-MR was always performed after PET-CT completion (Boellaard ). Although delayed PET acquisition may improve image quality by decreasing background activity, it is unclear whether this improves diagnostic accuracy (Chen ; Laffon ; Cheng ). Our PET-MR protocol includes several sequences aimed to allow a comprehensive whole-body staging as well as a local breast staging, at the cost of a lengthy examination. Although we are in the process of reducing the duration of the PET-MR study and the number of sequences employed, the aim of the current study was not related to sequence comparison and protocol refinement. Moreover, the evaluation of multiple sequences might account for the absence of false positive cases that might potentially have occurred relying only on DWI or on selected sequences for the diagnosis. Finally, larger studies will be needed to confirm our preliminary results.
Conclusions
In the case of bony metastases from breast cancer, PET-MR showed bony metastases not visible on same-day PET-CT in 12% of the positive patients, impacting on patients' management, and also a higher number of bony metastases (141) than did same-day PET-CT (90).
Authors: Yu Mei Chen; Gang Huang; Xiao Guang Sun; Jian Jun Liu; Tao Chen; Yi Ping Shi; Liang Rong Wan Journal: Nucl Med Commun Date: 2008-05 Impact factor: 1.690
Authors: M Ohta; Y Tokuda; Y Suzuki; M Kubota; H Makuuchi; T Tajima; S Nasu; Y Suzuki; S Yasuda; A Shohtsu Journal: Nucl Med Commun Date: 2001-08 Impact factor: 1.690
Authors: Gerwin P Schmidt; Stefan O Schoenberg; Rupert Schmid; Robert Stahl; Reinhold Tiling; Christoph R Becker; Maximilian F Reiser; Andrea Baur-Melnyk Journal: Eur Radiol Date: 2006-09-02 Impact factor: 5.315
Authors: Ullrich G Mueller-Lisse; Ulrike L Mueller-Lisse; Thomas Meindl; Eva Coppenrath; Christoph Degenhart; Anno Graser; Michael Scherr; Maximilian F Reiser Journal: Eur Radiol Date: 2007-02-22 Impact factor: 5.315
Authors: Gerald Antoch; Jörg Stattaus; Andre T Nemat; Simone Marnitz; Thomas Beyer; Hilmar Kuehl; Andreas Bockisch; Jörg F Debatin; Lutz S Freudenberg Journal: Radiology Date: 2003-09-25 Impact factor: 11.105
Authors: Didier Lardinois; Walter Weder; Thomas F Hany; Ehab M Kamel; Stephan Korom; Burkhardt Seifert; Gustav K von Schulthess; Hans C Steinert Journal: N Engl J Med Date: 2003-06-19 Impact factor: 91.245
Authors: Onofrio Antonio Catalano; Vincent Wu; Umar Mahmood; Alberto Signore; Mark Vangel; Andrea Soricelli; Marco Salvatore; Debra Gervais; Bruce R Rosen Journal: Am J Nucl Med Mol Imaging Date: 2018-02-05
Authors: Verena Sailer; Marc H Schiffman; Myriam Kossai; Joanna Cyrta; Shaham Beg; Brian Sullivan; Bradley B Pua; Kyungmouk Steve Lee; Adam D Talenfeld; David M Nanus; Scott T Tagawa; Brian D Robinson; Rema A Rao; Chantal Pauli; Rohan Bareja; Luis S Beltran; Alexandros Sigaras; Kenneth Wa Eng; Olivier Elemento; Andrea Sboner; Mark A Rubin; Himisha Beltran; Juan Miguel Mosquera Journal: Cancer Date: 2017-12-19 Impact factor: 6.860
Authors: Amy N Melsaether; Roy A Raad; Akshat C Pujara; Fabio D Ponzo; Kristine M Pysarenko; Komal Jhaveri; James S Babb; Eric E Sigmund; Sungheon G Kim; Linda A Moy Journal: Radiology Date: 2016-03-29 Impact factor: 11.105
Authors: Brian S Pugmire; Alexander R Guimaraes; Ruth Lim; Alison M Friedmann; Mary Huang; David Ebb; Howard Weinstein; Onofrio A Catalano; Umar Mahmood; Ciprian Catana; Michael S Gee Journal: World J Radiol Date: 2016-03-28