Literature DB >> 16493012

Hepatic metastases: diffusion-weighted sensitivity-encoding versus SPIO-enhanced MR imaging.

Katsuhiro Nasu1, Yoshihumi Kuroki, Shigeru Nawano, Seiko Kuroki, Tatsuaki Tsukamoto, Seiji Yamamoto, Ken Motoori, Takuya Ueda.   

Abstract

PURPOSE: To retrospectively compare accuracy of diffusion-weighted (DW) single-shot echo-planar imaging with sensitivity encoding (SENSE) with that of superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging in the evaluation of hepatic metastases due to extrahepatic malignancies.
MATERIALS AND METHODS: Patients provided informed consent; ethics committee approval was not required. The data of 24 patients (16 men, eight women; age range, 41-68 years; mean age, 61.9 years) with 40 resected hepatic metastases were retrospectively reviewed. Before SPIO administration, DW SENSE imaging and T2-weighted fast spin-echo (SE) and T1-weighted dual-echo fast field-echo (FFE) MR imaging were performed. After SPIO administration, T2-weighted fast SE, T1-weighted dual-echo, and T2*-weighted FFE MR examinations were performed. Images were divided into two sets: The SPIO-enhanced MR image set consisted of pre- and postcontrast T2-weighted fast SE and dual-echo T1-weighted FFE images and postcontrast T2*-weighted FFE images. The DW SENSE image set included DW SENSE images and precontrast T2-weighted fast SE and dual-echo T1-weighted FFE images. Three radiologists individually interpreted these images and sorted the confidence levels for presence of hepatic metastasis in each section into five grades. Area under the receiver operating characteristic (ROC) curve (A(z)) was calculated for each image set.
RESULTS: Hepatic metastases showed higher signal intensity on DW SENSE images than on T2-weighted fast SE images. Conversely, signals from vessels and cysts were suppressed with DW SENSE imaging. ROC analysis showed higher A(z) values when the DW SENSE image set was interpreted (0.90) than when the SPIO-enhanced MR image set was interpreted (0.81). The sensitivity and specificity, respectively, of total cases were 0.66 and 0.90, for the SPIO-enhanced MR image set and 0.82 and 0.94 for the DW SENSE image set. During SPIO-enhanced MR image interpretation, lesions 1 cm in diameter or smaller showed significantly lower sensitivity than lesions larger than 1 cm in diameter. During both interpretation sessions, left lobe lesions showed significantly lower sensitivity than right lobe lesions.
CONCLUSION: Combined reading of DW SENSE images and T2-weighted fast SE and dual-echo T1-weighted FFE MR images showed higher accuracy in the detection of hepatic metastases than did reading of SPIO-enhanced MR images. (c) RSNA, 2006.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16493012     DOI: 10.1148/radiol.2383041384

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  70 in total

1.  Combining diffusion-weighted MRI with Gd-EOB-DTPA-enhanced MRI improves the detection of colorectal liver metastases.

Authors:  D-M Koh; D J Collins; T Wallace; I Chau; A M Riddell
Journal:  Br J Radiol       Date:  2011-12-13       Impact factor: 3.039

2.  Sclerosed hemangioma of the liver: possible diagnostic value of diffusion-weighted magnetic resonance imaging.

Authors:  Tomoyuki Hida; Akihiro Nishie; Tsuyoshi Tajima; Akinobu Taketomi; Shin-ichi Aishima; Hiroshi Honda
Journal:  Jpn J Radiol       Date:  2010-05-01       Impact factor: 2.374

3.  Diffusion-weighted magnetic resonance imaging in focal breast lesions: analysis of 78 cases with pathological correlation.

Authors:  F Fornasa; L Pinali; A Gasparini; E Toniolli; S Montemezzi
Journal:  Radiol Med       Date:  2010-10-06       Impact factor: 3.469

4.  Diffusion-weighted and diffusion-tensor imaging of normal and diseased uterus.

Authors:  Duygu Kara Bozkurt; Murat Bozkurt; Mehmet Ali Nazli; Ilhan Nahit Mutlu; Ozgur Kilickesmez
Journal:  World J Radiol       Date:  2015-07-28

5.  Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique.

Authors:  Melanie Bruegel; Konstantin Holzapfel; Jochen Gaa; Klaus Woertler; Simone Waldt; Berthold Kiefer; Alto Stemmer; Carl Ganter; Ernst J Rummeny
Journal:  Eur Radiol       Date:  2007-10-25       Impact factor: 5.315

6.  Contribution of diffusion-weighted MR imaging for predicting benignity of complex adnexal masses.

Authors:  Isabelle Thomassin-Naggara; Emile Daraï; Charles A Cuenod; Laure Fournier; Irwin Toussaint; Claude Marsault; Marc Bazot
Journal:  Eur Radiol       Date:  2009-02-13       Impact factor: 5.315

7.  Feasibility of diffusion-weighted imaging under split breath-hold acquisition and postprocessing (DWI-SBAP): an attempt to suppress hepatic pseudo-anisotropy.

Authors:  Katsuhiro Nasu; Yoshifumi Kuroki; Manabu Minami
Journal:  Jpn J Radiol       Date:  2009-03-12       Impact factor: 2.374

8.  Diffusion-weighted images (DWI) without ADC values in assessment of small focal nodules in cirrhotic liver.

Authors:  Mai-Lin Chen; Xiao-Yan Zhang; Li-Ping Qi; Qing-Lei Shi; Bin Chen; Ying-Shi Sun
Journal:  Chin J Cancer Res       Date:  2014-02       Impact factor: 5.087

Review 9.  Imaging of liver cancer.

Authors:  Ben Ariff; Claire R Lloyd; Sameer Khan; Mohamed Shariff; Andrew V Thillainayagam; Devinder S Bansi; Shahid A Khan; Simon D Taylor-Robinson; Adrian K P Lim
Journal:  World J Gastroenterol       Date:  2009-03-21       Impact factor: 5.742

10.  Diffusion-weighted and T2-weighted MR imaging for colorectal liver metastases detection in a rat model at 7 T: a comparative study using histological examination as reference.

Authors:  Mathilde Wagner; Léon Maggiori; Maxime Ronot; Valérie Paradis; Valérie Vilgrain; Yves Panis; Bernard E Van Beers
Journal:  Eur Radiol       Date:  2013-03-02       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.