Literature DB >> 25787040

Considerations for SphygmoCor radial artery pulse wave analysis: side selection and peripheral arterial blood pressure calibration.

Jeffrey S Martin1,2, Alexandra R Borges1, John B Christy3, Darren T Beck3.   

Abstract

Methods employed for pulse wave analysis (PWA) and peripheral blood pressure (PBP) calibration vary. The purpose of this study was to evaluate the agreement of SphygmoCor PWA parameters derived from radial artery tonometry when considering (1) timing (before vs. after tonometry) and side selection (ipsilateral vs. contralateral limb) for PBP calibration and (2) side selection for tonometry (left vs. right arm). In 34 subjects (aged 21.9 ± 2.3 years), bilateral radial artery tonometry was performed simultaneously on three instances. PBP assessment via oscillometric sphygmomanometry in the left arm only and both arms simultaneously occurred following the first and second instances of tonometry, respectively. Significant within arm differences in PWA parameters derived before and after PBP measurement were observed in the right arm only (for example, aortic systolic blood pressure, Δ=0.38 ± 0.64 mm Hg). Simultaneously captured bilateral PWA variables demonstrated significant between arm differences in 88% (14/16) and 56% (9/16) of outcome variables when calibrated to within arm and equivalent PBP, respectively. Moreover, the right arm consistently demonstrated lower values for clinical PWA variables (for example, augmentation index, bias=-2.79%). However, 26% (n=9) of participants presented with clinically significant differences (>10 mm Hg) in bilateral PBP and their exclusion from analysis abolished most between arm differences observed. SphygmoCor PWA in the right radial artery results in greater variability independent of the timing of PBP measurement and magnitude of calibration pressures in young subjects. Moreover, bilateral PBP measurement is imperative to identify subjects in whom a significant difference in bilateral PWA outcomes may exist.

Entities:  

Mesh:

Year:  2015        PMID: 25787040     DOI: 10.1038/hr.2015.36

Source DB:  PubMed          Journal:  Hypertens Res        ISSN: 0916-9636            Impact factor:   3.872


  44 in total

1.  Reproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis.

Authors:  I B Wilkinson; S A Fuchs; I M Jansen; J C Spratt; G D Murray; J R Cockcroft; D J Webb
Journal:  J Hypertens       Date:  1998-12       Impact factor: 4.844

2.  Validity of a novel wristband tonometer for measuring central hemodynamics and augmentation index.

Authors:  Darren T Beck; Jeffrey S Martin; Wilmer W Nichols; Alvaro N Gurovich; Randy W Braith
Journal:  Am J Hypertens       Date:  2014-02-21       Impact factor: 2.689

3.  Differences in arterial stiffness at rest and after acute exercise between young men and women.

Authors:  Robert J Doonan; Andrew Mutter; Giordano Egiziano; Yessica-Haydee Gomez; Stella S Daskalopoulou
Journal:  Hypertens Res       Date:  2012-10-11       Impact factor: 3.872

4.  National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers.

Authors:  W B White; A S Berson; C Robbins; M J Jamieson; L M Prisant; E Roccella; S G Sheps
Journal:  Hypertension       Date:  1993-04       Impact factor: 10.190

5.  The normal difference in bilateral indirect blood pressure recordings in hypertensive individuals.

Authors:  Gene R Pesola; Helen R Pesola; Ming Lin; Michael J Nelson; Richard E Westfal
Journal:  Acad Emerg Med       Date:  2002-04       Impact factor: 3.451

6.  Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research.

Authors:  Thomas G Pickering; John E Hall; Lawrence J Appel; Bonita E Falkner; John Graves; Martha N Hill; Daniel W Jones; Theodore Kurtz; Sheldon G Sheps; Edward J Roccella
Journal:  Circulation       Date:  2005-02-08       Impact factor: 29.690

7.  Validation of a generalized transfer function to noninvasively derive central blood pressure during exercise.

Authors:  James E Sharman; Richard Lim; Ahmad M Qasem; Jeff S Coombes; Malcolm I Burgess; Jeff Franco; Paul Garrahy; Ian B Wilkinson; Thomas H Marwick
Journal:  Hypertension       Date:  2006-05-01       Impact factor: 10.190

8.  Association between wasted pressure effort and left ventricular hypertrophy in hypertension: influence of arterial wave reflection.

Authors:  Junichiro Hashimoto; Wilmer W Nichols; Michael F O'Rourke; Yutaka Imai
Journal:  Am J Hypertens       Date:  2008-01-17       Impact factor: 2.689

9.  Assessment of arterial stiffness in hypertension: comparison of oscillometric (Arteriograph), piezoelectronic (Complior) and tonometric (SphygmoCor) techniques.

Authors:  Noor A Jatoi; Azra Mahmud; Kathleen Bennett; John Feely
Journal:  J Hypertens       Date:  2009-11       Impact factor: 4.844

10.  Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension.

Authors:  Jalil Belghazi; Ramzi N El Feghali; Thérèse Moussalem; Maya Rejdych; Roland G Asmar
Journal:  Vasc Health Risk Manag       Date:  2007
View more
  8 in total

1.  Noninvasive estimation of central blood pressure and analysis of pulse waves by applanation tonometry.

Authors:  Paolo Salvi; Andrea Grillo; Gianfranco Parati
Journal:  Hypertens Res       Date:  2015-07-09       Impact factor: 3.872

2.  Mean arterial pressure values calculated using seven different methods and their associations with target organ deterioration in a single-center study of 1878 individuals.

Authors:  Theodore G Papaioannou; Athanase D Protogerou; Dimitrios Vrachatis; Giorgos Konstantonis; Evaggelia Aissopou; Antonis Argyris; Efthimia Nasothimiou; Elias J Gialafos; Marianna Karamanou; Dimitris Tousoulis; Petros P Sfikakis
Journal:  Hypertens Res       Date:  2016-05-19       Impact factor: 3.872

3.  Peripheral conduit and resistance artery function are improved following a single, 1-h bout of peristaltic pulse external pneumatic compression.

Authors:  Jeffrey S Martin; Alexandra R Borges; Darren T Beck
Journal:  Eur J Appl Physiol       Date:  2015-05-16       Impact factor: 3.078

4.  Differential vascular reactivity responses acutely following ingestion of a nitrate rich red spinach extract.

Authors:  Cody T Haun; Wesley C Kephart; Angelia M Holland; Christopher B Mobley; Anna E McCloskey; Joshua J Shake; David D Pascoe; Michael D Roberts; Jeffrey S Martin
Journal:  Eur J Appl Physiol       Date:  2016-09-30       Impact factor: 3.078

5.  Arterial Stiffness and Indices of Left Ventricular Diastolic Dysfunction in Patients with Embolic Stroke of Undetermined Etiology.

Authors:  Paulina Gąsiorek; Agata Sakowicz; Maciej Banach; Stephan von Haehling; Agata Bielecka-Dabrowa
Journal:  Dis Markers       Date:  2019-09-12       Impact factor: 3.434

6.  Obesity and Body Mass Components Influence Exercise Tolerance and the Course of Hypertension in Perimenopausal Women.

Authors:  Agata Bielecka-Dabrowa; Katarzyna Gryglewska; Agata Sakowicz; Marek Rybak; Kamil Janikowski; Maciej Banach
Journal:  J Cardiovasc Dev Dis       Date:  2022-07-27

7.  Influence of the central-to-peripheral arterial stiffness gradient on the timing and amplitude of wave reflections.

Authors:  Stacey S Hickson; Wilmer W Nichols; Barry J McDonnell; John R Cockcroft; Ian B Wilkinson; Carmel M McEniery
Journal:  Hypertens Res       Date:  2016-06-16       Impact factor: 3.872

8.  Unilateral application of an external pneumatic compression therapy improves skin blood flow and vascular reactivity bilaterally.

Authors:  Jeffrey S Martin; Allison M Martin; Petey W Mumford; Lorena P Salom; Angelique N Moore; David D Pascoe
Journal:  PeerJ       Date:  2018-05-29       Impact factor: 2.984

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.