Literature DB >> 25751834

Repeatability and inter-device agreement for three different methods of keratometry: Placido, Scheimpflug, and color LED corneal topography.

Irene Ruiz Hidalgo, Jos J Rozema, Sorcha Ní Dhubhghaill, Nadia Zakaria, Carina Koppen, Marie-José Tassignon.   

Abstract

PURPOSE: To determine the repeatability of a color LED corneal topographer (Cassini; iOptics, The Hague, The Netherlands) and compare it with Placido and Scheimpflug based devices (EyeSys 2000; EyeSys Laboratories, Houston, TX, and Pentacam HR; Oculus Optikgeräte GmbH, Wetzlar, Germany).
METHODS: This prospective study involved 20 healthy volunteers (20 eyes) recruited from the staff of the Antwerp University Hospital. For each eye, three measurements were taken using each device, from which eight parameters describing keratometry and astigmatism were derived. Repeatability was assessed using intrasession, within-subject analysis of variance. Agreement was evaluated between pairs of devices with Bland- Altman plots and 95% confidence intervals.
RESULTS: The repeatability values were good for all three devices, although slightly worse for the Cassini than for the other two devices for steep, flat, and mean keratometry. The EyeSys showed worse repeatability for the astigmatism axis. EyeSys and Pentacam agreed well with each other in terms of mean keratometry, whereas the Cassini gave consistently higher values by 0.52 diopters (D) when compared with the EyeSys (P < .05, paired t test) and by 0.38 D when compared with the Pentacam (P < .05, paired t test). The Cassini provided similar repeatability values (2.31°) for the astigmatism axis to the Pentacam (2.22°), in contrast to the EyeSys, which produced much more variable axes (9.0°) (P < .05, paired t test).
CONCLUSIONS: Overall, the three devices display comparable repeatability. The one exception is the astigmatism axis measurement of the EyeSys. The Cassini provides higher keratometry values than the other two devices, but the astigmatism axis agrees well with that provided by the Pentacam. Copyright 2015, SLACK Incorporated.

Entities:  

Mesh:

Year:  2015        PMID: 25751834     DOI: 10.3928/1081597X-20150224-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  11 in total

1.  Placido disk-based topography versus high-resolution rotating Scheimpflug camera for corneal power measurements in keratoconic and post-LASIK eyes: reliability and agreement.

Authors:  Rachele R Penna; Ugo de Sanctis; Martina Catalano; Luca Brusasco; Federico M Grignolo
Journal:  Int J Ophthalmol       Date:  2017-03-18       Impact factor: 1.779

2.  Validation of corneal topographic and aberrometric measurements obtained by color light-emitting diode reflection topography in healthy eyes.

Authors:  David P Piñero; Ainhoa Molina-Martín; Vicent J Camps; Dolores de Fez; María Teresa Caballero
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-09-03       Impact factor: 3.117

3.  Effect of the posterior corneal surface on total corneal astigmatism in patients with age-related cataract.

Authors:  Ying-Ying Jin; Zhen Zhou; Xiao-Yong Yuan; Hui Song; Xin Tang
Journal:  Int J Ophthalmol       Date:  2018-06-18       Impact factor: 1.779

4.  Custom air puff-derived biomechanical variables in a refractive surgery screening setting: Study from 2 centers.

Authors:  Vinicius S De Stefano; Ibrahim Seven; J Bradley Randleman; William J Dupps
Journal:  J Cataract Refract Surg       Date:  2018-05       Impact factor: 3.351

5.  Outcomes of toric IOL implantation guided by iris-registered femtosecond laser capsulotomy markings.

Authors:  Bradley P O'Neill; Vasilios F Diakonis; Konstantinos T Tsaousis; Robert J Weinstock
Journal:  Int Ophthalmol       Date:  2021-07-27       Impact factor: 2.031

6.  Corneal Topographic and Aberrometric Measurements Obtained with a Multidiagnostic Device in Healthy Eyes: Intrasession Repeatability.

Authors:  David P Piñero; Alberto López-Navarro; Inmaculada Cabezos; Dolores de Fez; María T Caballero; Vicent J Camps
Journal:  J Ophthalmol       Date:  2017-01-04       Impact factor: 1.909

Review 7.  Optimizing outcomes with toric intraocular lenses.

Authors:  Manpreet Kaur; Farin Shaikh; Ruchita Falera; Jeewan S Titiyal
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

8.  Predictability of different calculators in the minimization of postoperative astigmatism after implantation of a toric intraocular lens.

Authors:  Filomena J Ribeiro; Tiago B Ferreira; Catarina Relha; Carina Esteves; Sylvia Gaspar
Journal:  Clin Ophthalmol       Date:  2019-08-29

9.  A novel color-LED corneal topographer to assess astigmatism in pseudophakic eyes.

Authors:  Tiago B Ferreira; Filomena J Ribeiro
Journal:  Clin Ophthalmol       Date:  2016-08-13

10.  Comparability and repeatability of different methods of corneal astigmatism assessment.

Authors:  Tiago B Ferreira; Filomena J Ribeiro
Journal:  Clin Ophthalmol       Date:  2017-12-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.