Literature DB >> 25699232

High-level disinfection of gastrointestinal endoscope reprocessing.

King-Wah Chiu1, Lung-Sheng Lu1, Shue-Shian Chiou1.   

Abstract

High level disinfection (HLD) of the gastrointestinal (GI) endoscope is not simply a slogan, but rather is a form of experimental monitoring-based medicine. By definition, GI endoscopy is a semicritical medical device. Hence, such medical devices require major quality assurance for disinfection. And because many of these items are temperature sensitive, low-temperature chemical methods, such as liquid chemical germicide, must be used rather than steam sterilization. In summarizing guidelines for infection prevention and control for GI endoscopy, there are three important steps that must be highlighted: manual washing, HLD with automated endoscope reprocessor, and drying. Strict adherence to current guidelines is required because compared to any other medical device, the GI endoscope is associated with more outbreaks linked to inadequate cleaning or disinfecting during HLD. Both experimental evaluation on the surveillance bacterial cultures and in-use clinical results have shown that, the monitoring of the stringent processes to prevent and control infection is an essential component of the broader strategy to ensure the delivery of safe endoscopy services, because endoscope reprocessing is a multistep procedure involving numerous factors that can interfere with its efficacy. Based on our years of experience in the surveillance of culture monitoring of endoscopic reprocessing, we aim in this study to carefully describe what details require attention in the GI endoscopy disinfection and to share our experience so that patients can be provided with high quality and safe medical practices. Quality management encompasses all aspects of pre- and post-procedural care including the efficiency of the endoscopy unit and reprocessing area, as well as the endoscopic procedure itself.

Entities:  

Keywords:  Automated endoscope reprocessor; Bacterial culture; Gastrointestinal endoscopy; High-level disinfection; Liquid chemical germicide

Year:  2015        PMID: 25699232      PMCID: PMC4308530          DOI: 10.5493/wjem.v5.i1.33

Source DB:  PubMed          Journal:  World J Exp Med        ISSN: 2220-315X


  26 in total

1.  Pitfalls in endoscope reprocessing: brushing of air and water channels is mandatory for high-level disinfection.

Authors:  Y Ishino; K Ido; H Koiwai; K Sugano
Journal:  Gastrointest Endosc       Date:  2001-02       Impact factor: 9.427

2.  An outbreak of multidrug-resistant Pseudomonas aeruginosa infection associated with contamination of bronchoscopes and an endoscope washer-disinfector.

Authors:  S Schelenz; G French
Journal:  J Hosp Infect       Date:  2000-09       Impact factor: 3.926

3.  Patient-to-patient transmission of hepatitis C virus during colonoscopy.

Authors:  J P Bronowicki; V Venard; C Botté; N Monhoven; I Gastin; L Choné; H Hudziak; B Rihn; C Delanoë; A LeFaou; M A Bigard; P Gaucher; B Rhin
Journal:  N Engl J Med       Date:  1997-07-24       Impact factor: 91.245

4.  Assessment on experimental bacterial biofilms and in clinical practice of the efficacy of sampling solutions for microbiological testing of endoscopes.

Authors:  C Aumeran; E Thibert; F A Chapelle; C Hennequin; O Lesens; O Traoré
Journal:  J Clin Microbiol       Date:  2011-12-14       Impact factor: 5.948

5.  Swab culture monitoring of automated endoscope reprocessors after high-level disinfection.

Authors:  Lung-Sheng Lu; Keng-Liang Wu; Yi-Chun Chiu; Ming-Tzung Lin; Tsung-Hui Hu; King-Wah Chiu
Journal:  World J Gastroenterol       Date:  2012-04-14       Impact factor: 5.742

Review 6.  Sterilization of endoscopic instruments.

Authors:  Ravindra B Sabnis; Amit Bhattu; Mohankumar Vijaykumar
Journal:  Curr Opin Urol       Date:  2014-03       Impact factor: 2.309

7.  Diagnostic pitfall of sebaceous gland metaplasia of the esophagus.

Authors:  King-Wah Chiu; Cheng-Kun Wu; Long-Sheng Lu; Hock-Liew Eng; Shue-Shian Chiou
Journal:  World J Clin Cases       Date:  2014-07-16       Impact factor: 1.337

Review 8.  Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy.

Authors:  Julia Kovaleva; Frans T M Peters; Henny C van der Mei; John E Degener
Journal:  Clin Microbiol Rev       Date:  2013-04       Impact factor: 26.132

9.  Endoscopic biopsy as quality assurance for endoscopic services.

Authors:  King-Wah Chiu; Shue-Shian Chiou
Journal:  PLoS One       Date:  2013-11-12       Impact factor: 3.240

10.  Shared air: a renewed focus on ventilation for the prevention of tuberculosis transmission.

Authors:  Eugene T Richardson; Carl D Morrow; Darryl B Kalil; Samuel Ginsberg; Linda-Gail Bekker; Robin Wood
Journal:  PLoS One       Date:  2014-05-07       Impact factor: 3.240

View more
  6 in total

Review 1.  Gastrointestinal Endoscopy-Associated Infections: Update on an Emerging Issue.

Authors:  Anasua Deb; Abhilash Perisetti; Hemant Goyal; Mark M Aloysius; Sonali Sachdeva; Dushyant Dahiya; Neil Sharma; Nirav Thosani
Journal:  Dig Dis Sci       Date:  2022-03-09       Impact factor: 3.487

2.  Super-achromatic optical coherence tomography capsule for ultrahigh-resolution imaging of esophagus.

Authors:  Kaiyan Li; Wenxuan Liang; Jessica Mavadia-Shukla; Hyeon-Cheol Park; Dawei Li; Wu Yuan; Suiren Wan; Xingde Li
Journal:  J Biophotonics       Date:  2018-11-13       Impact factor: 3.207

Review 3.  Role of Clinical Endoscopy in Emphasizing Endoscope Disinfection.

Authors:  Ji Kon Ryu; Eun Young Kim; Kwang An Kwon; Il Ju Choi; Ki Baik Hahm
Journal:  Clin Endosc       Date:  2015-09-30

Review 4.  Recent Update on Microbiological Monitoring of Gastrointestinal Endoscopes after High-Level Disinfection.

Authors:  Suk Pyo Shin; Won Hee Kim
Journal:  Clin Endosc       Date:  2015-09-30

5.  Recent upper gastrointestinal panendoscopy increases the risk of pyogenic liver abscess.

Authors:  Ming-Jen Tsai; Chin-Li Lu; Ying C Huang; Chung Hsien Liu; Wan-Ting Huang; Kai-Yuan Cheng; Solomon Chih-Cheng Chen
Journal:  World J Gastroenterol       Date:  2017-04-28       Impact factor: 5.742

6.  Is Post-Reprocessing Microbiological Surveillance of Duodenoscopes Effective in Reducing the Potential Risk in Transmitting Pathogens?

Authors:  Maria Luisa Cristina; Marina Sartini; Elisa Schinca; Gianluca Ottria; Chiara Dupont; Palmira Bova; Gianni Coccia; Beatrice Casini; Anna Maria Spagnolo
Journal:  Int J Environ Res Public Health       Date:  2019-12-24       Impact factor: 3.390

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.