Literature DB >> 24451088

Sterilization of endoscopic instruments.

Ravindra B Sabnis1, Amit Bhattu, Mohankumar Vijaykumar.   

Abstract

PURPOSE OF REVIEW: Sterilization of endoscopic instruments is an important but often ignored topic. The purpose of this article is to review the current literature on the sterilization of endoscopic instruments and elaborate on the appropriate sterilization practices. RECENT FINDING: Autoclaving is an economic and excellent method of sterilizing the instruments that are not heat sensitive. Heat sensitive instruments may get damaged with hot sterilization methods. Several new endoscopic instruments such as flexible ureteroscopes, chip on tip endoscopes, are added in urologists armamentarium. Many of these instruments are heat sensitive and hence alternative efficacious methods of sterilization are necessary. Although ethylene oxide and hydrogen peroxide are excellent methods of sterilization, they have some drawbacks. Gamma irradiation is mainly for disposable items. Various chemical agents are widely used even though they achieve high-level disinfection rather than sterilization. This article reviews various methods of endoscopic instrument sterilization with their advantages and drawbacks.
SUMMARY: If appropriate sterilization methods are adopted, then it not only will protect patients from procedure-related infections but prevent hypersensitive allergic reactions. It will also protect instruments from damage and increase its longevity.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24451088     DOI: 10.1097/MOU.0000000000000034

Source DB:  PubMed          Journal:  Curr Opin Urol        ISSN: 0963-0643            Impact factor:   2.309


  9 in total

Review 1.  High-level disinfection of gastrointestinal endoscope reprocessing.

Authors:  King-Wah Chiu; Lung-Sheng Lu; Shue-Shian Chiou
Journal:  World J Exp Med       Date:  2015-02-20

2.  Comparative medico-economic study of reusable vs. single-use flexible ureteroscopes.

Authors:  Khalid Al-Balushi; Nathalie Martin; Hélène Loubon; Michael Baboudjian; Floriane Michel; Pierre-Clément Sichez; Thomas Martin; Eugénie Di-Crocco; Sarah Gaillet; Veronique Delaporte; Akram Akiki; Alice Faure; Gilles Karsenty; Eric Lechevallier; Romain Boissier
Journal:  Int Urol Nephrol       Date:  2019-07-17       Impact factor: 2.370

3.  A multiport MR-compatible neuroendoscope: spanning the gap between rigid and flexible scopes.

Authors:  Sunil Manjila; Margherita Mencattelli; Benoit Rosa; Karl Price; Georgios Fagogenis; Pierre E Dupont
Journal:  Neurosurg Focus       Date:  2016-09       Impact factor: 4.047

4.  Outcomes and Cost Evaluation Related to a Single-Use, Disposable Ureteric Stent Removal System: a Systematic Review of the Literature.

Authors:  Thomas Hughes; Amelia Pietropaolo; Patrick Jones; Marco Oderda; Paolo Gontero; Bhaskar K Somani
Journal:  Curr Urol Rep       Date:  2021-06-15       Impact factor: 3.092

5.  Prospective comparative study between the effect of CIDEX® OPA and STERRAD NX on the durability of digital flexible ureteroscope.

Authors:  Saeed H Al Qahtani; Mohamed H Abdelhamied; Abdulrahman H AlMuhrij; Mizyad Y Al Rawashada; Ahmed M Al Askar; Amr M Abdelhamid; Tarek K Fath El-Bab; Ehab M Galal; Mahmoud S Eladawy
Journal:  World J Urol       Date:  2019-05-13       Impact factor: 4.226

6.  Is the environment of the endoscopy unit a reservoir of pathogens?

Authors:  Eun Sung Choi; Jae Hyuk Choi; Jung Min Lee; Sang Min Lee; Yoo Jin Lee; Yu Jin Kang; Eun Soo Kim; Kwang Bum Cho; Kyung Sik Park; Byoung Kuk Jang; Jae Seok Hwang; Woo Jin Chung; Nam Hee Ryoo; Seong Woo Jeon; Min Kyu Jung
Journal:  Intest Res       Date:  2014-10-27

7.  Is the Stella™ 5L system an effective cold sterilization technique for needle-based confocal miniprobes?

Authors:  Cai-Xia Wang; Yuan-Yuan Chen; Feng Yang; Fan Yang; Jin-Tao Guo; Siyu Sun; Ling Fan
Journal:  Endosc Ultrasound       Date:  2017 May-Jun       Impact factor: 5.628

8.  Is plasma sterilization the modality of choice of sterilization today for endourological procedures such as ureterorenoscopy and retrograde intrarenal surgery? A single-center retrospective evaluation of 198 patients.

Authors:  Kandarp Priyakant Parikh; Ravi Jineshkumar Jain; Aditya K Parikh
Journal:  Urol Ann       Date:  2020-04-14

9.  Disposal of the large volume of sputum positive for Mycobacterium tuberculosis by using microwave sterilisation technology as an alternative to traditional autoclaving in a tertiary respiratory care hospital in Delhi, India.

Authors:  Vithal Prasad Myneedu; Amit Aggarwal
Journal:  Infect Prev Pract       Date:  2020-06-30
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.