Literature DB >> 25644728

PIP breast implants: rupture rate and correlation with breast cancer.

M Moschetta, M Telegrafo, I Cornacchia, L Vincenti, V Ranieri, A Cirili, L Rella, A A Stabile Ianora, G Angelelli.   

Abstract

AIM: To evaluate the incidence of Poly Implant Prosthése (PIP) rupture as assessed by magnetic resonance imaging (MRI), the prevalence of the detected signs and the potential correlation with breast carcinoma. PATIENTS AND METHODS: 67 patients with silicone breast implants and clinical indications for breast MRI were evaluated for a total of 125 implants: 40 (32%) PIP in 21 patients and 85 non-PIP in 46 patients (68%), the latest considered as control group. A 1.5-T MR imaging device was used in order to assess implant integrity with dedicated sequences and in 6 cases a dynamic study was performed for characterizing breast lesions. Two radiologists with more than 5 years' experience in the field of MRI evaluated in consensus all MR images searching for the presence of clear signs of intra or extra-capsular implant rupture.
RESULTS: 20/40 (50%) PIP implants presented signs of intra-capsular rupture: linguine sign in 20 cases (100%), tear-drop sign in 6 (30%). In 12/20 cases (60%), MRI signs of extra-capsular rupture were detected. In the control group, an intra-capsular rupture was diagnosed in 12/85 cases (14%) associated with extra-capsular one in 5/12 cases (42%). Among the six cases with suspected breast lesions, in 2/21 patients with PIP implants (10%) a breast carcinoma was diagnosed (mucinous carcinoma, n=1; invasive ductal carcinoma, n=1). In 4/46 patients (9%) with non-PIP implants, an invasive ductal carcinoma was diagnosed.
CONCLUSION: The rupture rate of PIP breast implants is significantly higher than non-PIP (50% vs 14%). MRI represents the most accurate imaging tool for evaluating breast prostheses and the linguine sign is the most common MRI sign to be searched. The incidence of breast carcinoma does not significantly differ between the PIP and non-PIP implants and a direct correlation with breast cancer can not been demonstrated.

Entities:  

Mesh:

Year:  2014        PMID: 25644728      PMCID: PMC4321505     

Source DB:  PubMed          Journal:  G Chir        ISSN: 0391-9005


  19 in total

1.  The PIP mammary prosthesis: a product recall study.

Authors:  M G Berry; Jan J Stanek
Journal:  J Plast Reconstr Aesthet Surg       Date:  2012-03-09       Impact factor: 2.740

2.  Magnetic resonance imaging and explantation investigation of long-term silicone gel implant integrity.

Authors:  Nick Collis; Janet Litherland; David Enion; David T Sharpe
Journal:  Plast Reconstr Surg       Date:  2007-10       Impact factor: 4.730

3.  Intra-prosthetic breast MR virtual navigation: a preliminary study for a new evaluation of silicone breast implants.

Authors:  Marco Moschetta; Michele Telegrafo; Giulia Capuano; Leonarda Rella; Arnaldo Scardapane; Giuseppe Angelelli; Amato Antonio Stabile Ianora
Journal:  Magn Reson Imaging       Date:  2013-06-21       Impact factor: 2.546

Review 4.  Prosthetic breast implant rupture: imaging--pictorial essay.

Authors:  Giuseppe Colombo; Vittorio Ruvolo; Roberto Stifanese; Marco Perillo; Alessandro Garlaschi
Journal:  Aesthetic Plast Surg       Date:  2011-04-13       Impact factor: 2.326

5.  MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard.

Authors:  M C Maijers; F B Niessen; J F H Veldhuizen; M J P F Ritt; R A Manoliu
Journal:  Eur Radiol       Date:  2014-03-06       Impact factor: 5.315

6.  Prevalence of rupture in poly implant Prothèse silicone breast implants, recalled from the European market in 2010.

Authors:  Maria C Maijers; Francisus B Niessen
Journal:  Plast Reconstr Surg       Date:  2012-06       Impact factor: 4.730

7.  [Breast augmentation by Poly Implant Prothèses silicone implants: retrospective study about 99 patients. Rupture analysis and management].

Authors:  A Aktouf; I Auquit-Auckbur; D Coquerel-Beghin; V Delpierre; P-Y Milliez
Journal:  Ann Chir Plast Esthet       Date:  2012-05-29       Impact factor: 0.660

8.  PIP breast implant removal: a study of 828 cases.

Authors:  S Oulharj; J Pauchot; Y Tropet
Journal:  J Plast Reconstr Aesthet Surg       Date:  2013-12-30       Impact factor: 2.740

9.  Surface and mechanical analysis of explanted Poly Implant Prosthèse silicone breast implants.

Authors:  L Yildirimer; A M Seifalian; P E Butler
Journal:  Br J Surg       Date:  2013-03-08       Impact factor: 6.939

10.  PIP silicone breast implants: rupture rates based on the explantation of 676 implants in a single surgeon series.

Authors:  Omar Quaba; Awf Quaba
Journal:  J Plast Reconstr Aesthet Surg       Date:  2013-05-30       Impact factor: 2.740

View more
  2 in total

1.  An unusual case of a ruptured Poly Implant Prothèse breast implant associated with xanthoma.

Authors:  Andrii Dinets; Dmytro Unukovych; Vasyl Khrapach; Olga Zakhartseva; Volodymyr Sulik; Edgar Kaminskyi; Olexandr Khrapach; Ani Meloyan; Lubov Zakhartseva; Volodymyr Mishalov
Journal:  Case Reports Plast Surg Hand Surg       Date:  2016-03-11

2.  Imaging of common breast implants and implant-related complications: A pictorial essay.

Authors:  Amisha T Shah; Bijal B Jankharia
Journal:  Indian J Radiol Imaging       Date:  2016 Apr-Jun
  2 in total