Intra-prosthetic breast MR virtual navigation: a preliminary study for a new evaluation of silicone breast implants.

Marco Moschetta1, Michele Telegrafo, Giulia Capuano, Leonarda Rella, Arnaldo Scardapane, Giuseppe Angelelli, Amato Antonio Stabile Ianora.   

Abstract

OBJECTIVES: To assess the contribute of intra-prosthetic MRI virtual navigation for evaluating breast implants and detecting implant ruptures.
METHODS: Forty-five breast implants were evaluated by MR examination. Only patients with a clinical indication were assessed. A 1.5-T device equipped with a 4-channel breast coil was used by performing axial TSE-T2, axial silicone-only, axial silicone suppression and sagittal STIR images. The obtained dicom files were also analyzed by using virtual navigation software. Two blinded radiologists evaluated all MR and virtual images. Eight patients for a total of 13 implants underwent surgical replacement. Sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) were calculated for both imaging strategies.
RESULTS: Intra-capsular rupture was diagnosed in 13 out of 45 (29%) implants by using MRI. Basing on virtual navigation, 9 (20%) cases of intra-capsular rupture were diagnosed. Sensitivity, specificity, accuracy, PPV and NPV values of 100%, 86%, 89%, 62% and 100%, respectively, were found for MRI. Virtual navigation increased the previous values up to 100%, 97%, 98%, 89% and 100%.
CONCLUSION: Intra-prosthetic breast MR virtual navigation can represent an additional promising tool for the evaluation of breast implants being able to reduce false positives and to provide a more accurate detection of intra-capsular implant rupture signs.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Breast; Imaging; MRI; Prosthesis; Virtual

Mesh:

Substances:

Year:  2013        PMID: 23791545     DOI: 10.1016/j.mri.2013.05.004

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  3 in total

1.  Role of US in evaluating breast implant integrity.

Authors:  Michele Telegrafo; Marco Moschetta
Journal:  J Ultrasound       Date:  2015-06-23

2.  PIP breast implants: rupture rate and correlation with breast cancer.

Authors:  M Moschetta; M Telegrafo; I Cornacchia; L Vincenti; V Ranieri; A Cirili; L Rella; A A Stabile Ianora; G Angelelli
Journal:  G Chir       Date:  2014 Nov-Dec

3.  Comparison between fine needle aspiration cytology (FNAC) and core needle biopsy (CNB) in the diagnosis of breast lesions.

Authors:  M Moschetta; M Telegrafo; D A Carluccio; J P Jablonska; L Rella; Gabriella Serio; M Carrozzo; A A Stabile Ianora; G Angelelli
Journal:  G Chir       Date:  2014 Jul-Aug
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.