Literature DB >> 25636413

Impact of iterative reconstruction on the diagnosis of acute pulmonary embolism (PE) on reduced-dose chest CT angiograms.

François Pontana1, Simon Henry, Alain Duhamel, Jean-Baptiste Faivre, Nunzia Tacelli, Julien Pagniez, Jacques Remy, Martine Remy-Jardin.   

Abstract

PURPOSE: To evaluate the impact of iterative reconstruction on the detectability of clots. METHODS AND MATERIALS: Fifty-three patients were enrolled in a study comparing reduced-dose and full-dose images, available from the same dual-source data set. From each acquisition, three series of images were generated: (1) full-dose images (from both tubes), reconstructed with filtered back projection (FBP) (group 1; standard of reference), (2) reduced-dose images (from tube A only; 60 % dose reduction) reconstructed with FBP (group 2) and iterative reconstruction (SAFIRE) (group 3).
RESULTS: In group 1 (mean DLP: 264.6 mGy.cm), (1) PE was diagnosed in 8 patients (15 %) with 82 clots in the central (n = 5), segmental (n = 39) and subsegmental (n = 38) arteries and (2) mean level of noise was 30.56 ± 5.07. In group 2 (mean DLP: 105.8 mGy.cm), a significant increase in noise (44.56 ± 6.24; p < 0.0001) (1) hampered detection of PE in one patient and (2) altered detection of peripheral clots (12 false-negative and 2 false-positive results). In group 3, image noise was not significantly different from that in group 1 (p = 0.1525; effect size: 0.2683), with a similar detection of PE compared to group 1 (p = 1).
CONCLUSION: Reconstruction of reduced-dose images (60 % dose reduction) with SAFIRE provided image quality and diagnostic value comparable to those of full-dose FBP images. KEY POINTS: • Iterative reconstruction does not alter the detection of endoluminal clots. • Iterative reconstruction allows dose reduction in the context of acute PE. • Iterative reconstruction allows radiologists to approach the prospects of submilliSievert CT.

Entities:  

Mesh:

Year:  2015        PMID: 25636413     DOI: 10.1007/s00330-014-3393-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  23 in total

1.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

2.  CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings.

Authors:  Claudia Schueller-Weidekamm; Cornelia M Schaefer-Prokop; Michael Weber; Christian J Herold; Mathias Prokop
Journal:  Radiology       Date:  2006-12       Impact factor: 11.105

Review 3.  Radiation dose reduction in chest CT: a review.

Authors:  Takeshi Kubo; Pei-Jan Paul Lin; Wolfram Stiller; Masaya Takahashi; Hans-Ulrich Kauczor; Yoshiharu Ohno; Hiroto Hatabu
Journal:  AJR Am J Roentgenol       Date:  2008-02       Impact factor: 3.959

4.  Raw-data-based iterative reconstruction versus filtered back projection: image quality of low-dose chest computed tomography examinations in 87 patients.

Authors:  Haiyan Wang; Bingyi Tan; Bin Zhao; Changhu Liang; Zhuodong Xu
Journal:  Clin Imaging       Date:  2013-08-02       Impact factor: 1.605

Review 5.  Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society.

Authors:  Martine Remy-Jardin; Massimo Pistolesi; Lawrence R Goodman; Warren B Gefter; Alexander Gottschalk; John R Mayo; H Dirk Sostman
Journal:  Radiology       Date:  2007-09-11       Impact factor: 11.105

6.  Effect of computerized clinical decision support on the use and yield of CT pulmonary angiography in the emergency department.

Authors:  Ali S Raja; Ivan K Ip; Luciano M Prevedello; Aaron D Sodickson; Cameron Farkas; Richard D Zane; Richard Hanson; Samuel Z Goldhaber; Ritu R Gill; Ramin Khorasani
Journal:  Radiology       Date:  2011-12-20       Impact factor: 11.105

7.  Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Subba R Digumarthy; Jiang Hsieh; Homer Pien; Sarabjeet Singh; Matthew D Gilman; Jo-Anne O Shepard
Journal:  J Comput Assist Tomogr       Date:  2010-01       Impact factor: 1.826

8.  Sinogram-affirmed iterative reconstruction of low-dose chest CT: effect on image quality and radiation dose.

Authors:  Mannudeep K Kalra; Mischa Woisetschläger; Nils Dahlström; Sarabjeet Singh; Subbarao Digumarthy; Synho Do; Homer Pien; Petter Quick; Bernhard Schmidt; Martin Sedlmair; Jo-Anne O Shepard; Anders Persson
Journal:  AJR Am J Roentgenol       Date:  2013-08       Impact factor: 3.959

9.  Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study.

Authors:  Sarabjeet Singh; Mannudeep K Kalra; Matthew D Gilman; Jiang Hsieh; Homer H Pien; Subba R Digumarthy; Jo-Anne O Shepard
Journal:  Radiology       Date:  2011-03-08       Impact factor: 11.105

10.  CT pulmonary angiography: a comparative analysis of the utilization patterns in emergency department and hospitalized patients between 1998 and 2003.

Authors:  J David Prologo; Robert C Gilkeson; Mireya Diaz; Joe Asaad
Journal:  AJR Am J Roentgenol       Date:  2004-10       Impact factor: 3.959

View more
  13 in total

1.  Ultra-low dose contrast CT pulmonary angiography in oncology patients using a high-pitch helical dual-source technology.

Authors:  Prabhakar Rajiah; Leslie Ciancibello; Ronald Novak; Jennifer Sposato; Luis Landeras; Robert Gilkeson
Journal:  Diagn Interv Radiol       Date:  2019-05       Impact factor: 2.630

2.  90-kVp low-tube-voltage CT pulmonary angiography in combination with advanced modeled iterative reconstruction algorithm: effects on radiation dose, image quality and diagnostic accuracy for the detection of pulmonary embolism.

Authors:  Doris Leithner; Tatjana Gruber-Rouh; Martin Beeres; Julian L Wichmann; Scherwin Mahmoudi; Simon S Martin; Lukas Lenga; Moritz H Albrecht; Christian Booz; Thomas J Vogl; Jan-Erik Scholtz
Journal:  Br J Radiol       Date:  2018-06-05       Impact factor: 3.039

3.  Follow-up CT pulmonary angiograms in patients with acute pulmonary embolism.

Authors:  Paul D Stein; Fadi Matta; Patrick G Hughes; Zak N Hourmouzis; Nina P Hourmouzis; Robert E Schweiss; Jennifer A Bach; Viviane M Kazan; Edward J Kakish; Daniel C Keyes; Mary J Hughes
Journal:  Emerg Radiol       Date:  2016-07-12

4.  Attenuation-based kV pair selection in dual source dual energy computed tomography angiography of the chest: impact on radiation dose and image quality.

Authors:  Rahul D Renapurkar; Andrew Primak; Joseph Azok; Jason Lempel; Yasmeen Tandon; Jennifer Bullen; Frank Dong; Wadih Karim; Ruffin Graham
Journal:  Eur Radiol       Date:  2017-01-13       Impact factor: 5.315

5.  CT pulmonary angiogram quality comparison between early and later pregnancy.

Authors:  Yoel Siegel; Russ Kuker; James Banks; Gary Danton
Journal:  Emerg Radiol       Date:  2017-05-04

Review 6.  Imaging of acute pulmonary embolism: an update.

Authors:  Alastair J E Moore; Jason Wachsmann; Murthy R Chamarthy; Lloyd Panjikaran; Yuki Tanabe; Prabhakar Rajiah
Journal:  Cardiovasc Diagn Ther       Date:  2018-06

7.  CT pulmonary angiography: simultaneous low-pitch dual-source acquisition mode with 70 kVp and 40 ml of contrast medium and comparison with high-pitch spiral dual-source acquisition with automated tube potential selection.

Authors:  Johannes Boos; Patric Kröpil; Rotem S Lanzman; Joel Aissa; Christoph Schleich; Philipp Heusch; Lino M Sawicki; Gerald Antoch; Christoph Thomas
Journal:  Br J Radiol       Date:  2016-03-23       Impact factor: 3.039

8.  Clinical value of cardiac color ultrasound and cardiac troponin T combined with dynamic electrocardiogram in treatment of acute pulmonary embolism.

Authors:  Hongjun Li; Lixin Kang; Yongqiang Sun
Journal:  Exp Ther Med       Date:  2017-12-18       Impact factor: 2.447

9.  Image quality, diagnostic accuracy, and potential for radiation dose reduction in thoracoabdominal CT, using Sinogram Affirmed Iterative Reconstruction (SAFIRE) technique in a longitudinal study.

Authors:  Michael Scharf; Stephanie Brendel; Katja Melzer; Christian Hentschke; Matthias May; Michael Uder; Michael M Lell
Journal:  PLoS One       Date:  2017-07-05       Impact factor: 3.240

10.  Low-dose CT pulmonary angiography on a 15-year-old CT scanner: a feasibility study.

Authors:  Moritz Kaup; Tatjana Gruber-Rouh; Jan E Scholtz; Moritz H Albrecht; Andreas Bucher; Claudia Frellesen; Thomas J Vogl; Martin Beeres
Journal:  Acta Radiol Open       Date:  2016-12-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.