Caroline Scemama1, Philippe Anract2, Valérie Dumaine2, Antoine Babinet2, Jean Pierre Courpied2, Moussa Hamadouche2. 1. Department of Orthopaedic and Reconstructive Surgery, Clinical Orthopaedic Research Center, Centre Hospitalo-Universitaire Pitié Salpétrière, 83 boulevard de l'hôpital, 75013, Paris, France. scemamacaroline@gmail.com. 2. Department of Orthopaedic and Reconstructive Surgery, Clinical Orthopaedic Research Centre, Service A, Centre Hospitalo-Universitaire Cochin- Port Royal, 27 Rue du Faubourg St Jacques, 75014, Paris, France.
Abstract
PURPOSE: Some data indicate that first-generation highly cross-linked polyethylene (HXLPE) can oxidise in vivo and is associated with reduced mechanical properties. To overcome these limitations, a natural anti-oxidant vitamin E has been added to HXLPE to preserve the mechanical properties and decrease oxidative degradation whilst conserving high wear resistance. We hypothesised that after a minimal three years of follow-up the use of vitamin E-blended HXLPE would result in lower radiographic wear when compared with ultra-high molecular weight polyethylene (UHMWPE). METHODS:One hundred patients were randomised to receive hybrid total hip arthroplasty (THA) using a monoblock cementless acetabular component made either of UHMWPE or vitamin E-blended HXLPE. All other parameters were identical in both groups. Complete follow-up was available for 74 of these patients. Femoral head penetration was measured using a validated computer-assisted method. RESULTS: The median creep measured 0.111 mm (range, -0.576 - +0.444 mm) in the vitamin E-blended group versus 0.170 mm (range, -0.861 - +0.884 mm) in the UHMWPE group (difference of medians, 0.059; p = 0.046). The median steady state penetration rate was -0.008 mm/year (range, -0.88 - +0.64 mm/year) in the vitamin E-blended group versus 0.133 mm/year (range, -0.84 - +0.85 mm/year) in the UHMWPE group (difference of medians 0.141, p = 0.043). CONCLUSIONS: This study demonstrated that femoral head penetration was lower when using vitamin E-blended HXLPE when compared with UHMWPE, with a steady-state penetration rate far below the osteolysis threshold. Longer-term follow-up is needed to warrant whether wear reduction will generate less occurrence of osteolysis and aseptic loosening.
RCT Entities:
PURPOSE: Some data indicate that first-generation highly cross-linked polyethylene (HXLPE) can oxidise in vivo and is associated with reduced mechanical properties. To overcome these limitations, a natural anti-oxidant vitamin E has been added to HXLPE to preserve the mechanical properties and decrease oxidative degradation whilst conserving high wear resistance. We hypothesised that after a minimal three years of follow-up the use of vitamin E-blended HXLPE would result in lower radiographic wear when compared with ultra-high molecular weight polyethylene (UHMWPE). METHODS: One hundred patients were randomised to receive hybrid total hip arthroplasty (THA) using a monoblock cementless acetabular component made either of UHMWPE or vitamin E-blended HXLPE. All other parameters were identical in both groups. Complete follow-up was available for 74 of these patients. Femoral head penetration was measured using a validated computer-assisted method. RESULTS: The median creep measured 0.111 mm (range, -0.576 - +0.444 mm) in the vitamin E-blended group versus 0.170 mm (range, -0.861 - +0.884 mm) in the UHMWPE group (difference of medians, 0.059; p = 0.046). The median steady state penetration rate was -0.008 mm/year (range, -0.88 - +0.64 mm/year) in the vitamin E-blended group versus 0.133 mm/year (range, -0.84 - +0.85 mm/year) in the UHMWPE group (difference of medians 0.141, p = 0.043). CONCLUSIONS: This study demonstrated that femoral head penetration was lower when using vitamin E-blended HXLPE when compared with UHMWPE, with a steady-state penetration rate far below the osteolysis threshold. Longer-term follow-up is needed to warrant whether wear reduction will generate less occurrence of osteolysis and aseptic loosening.
Entities:
Keywords:
HXLPE; Polyethylene; Total hip arthroplasty; UHMWPE; Vitamin E; Wear
Authors: Keith K Wannomae; Shayan Bhattacharyya; Andrew Freiberg; Daniel Estok; William H Harris; Orhun Muratoglu Journal: J Arthroplasty Date: 2006-07-17 Impact factor: 4.757
Authors: Hannah Spece; Jaclyn T Schachtner; Daniel W MacDonald; Gregg R Klein; Michael A Mont; Gwo-Chin Lee; Steven M Kurtz Journal: J Arthroplasty Date: 2019-07-18 Impact factor: 4.757
Authors: Steffen Braun; Sebastian Jaeger; Robert Sonntag; Stefan Schroeder; J Philippe Kretzer Journal: Materials (Basel) Date: 2020-04-15 Impact factor: 3.623
Authors: André Busch; Marcus Jäger; Harald Engler; Marcel Haversath; Charlotte Bielefeld; Stefan Landgraeber; Alexander Wegner Journal: BMC Musculoskelet Disord Date: 2020-04-20 Impact factor: 2.362
Authors: Yama Afghanyar; Sebastian Joser; Jonas Tecle; Philipp Drees; Jens Dargel; Philipp Rehbein; Karl Philipp Kutzner Journal: BMC Musculoskelet Disord Date: 2021-01-23 Impact factor: 2.362
Authors: Joost H J van Erp; Julie R A Massier; Jelle J Halma; Thom E Snijders; Arthur de Gast Journal: Acta Orthop Date: 2020-02-26 Impact factor: 3.717