Literature DB >> 25612263

The development and initial evaluation of a realistic simulated SPECT dataset with simultaneous respiratory and cardiac motion for gated myocardial perfusion SPECT.

Taek-Soo Lee1, Benjamin M W Tsui.   

Abstract

We developed a realistic simulation dataset for simultaneous respiratory and cardiac (R&C) gated SPECT/CT using the 4D NURBS-based Cardiac-Torso (NCAT) Phantom and Monte Carlo simulation methods, and evaluated it for a sample application study. The 4D NCAT phantom included realistic respiratory motion and beating heart motion based on respiratory gated CT and cardiac tagged MRI data of normal human subjects. To model the respiratory motion, a set of 24 separate 3D NCAT phantoms excluding the heart was generated over a respiratory cycle. The beating heart motion was modeled separately with 48 frames per cardiac cycle for each of the 24 respiratory phases. The resultant set of 24  ×  48 3D NCAT phantoms provides a realistic model of a normal human subject at different phases of combined R&C motions. An almost noise-free SPECT projection dataset for each of the 1152 3D NCAT phantoms was generated using Monte Carlo simulation techniques and the radioactivity uptake distribution of (99m)Tc sestamibi in different organs. By grouping and summing the separate projection datasets, separate or simultaneous R&C gated acquired data with different gating schemes could be simulated. In the initial evaluation, we combined the projection datasets into ungated, 6 respiratory-gates only, 8 cardiac-gates only, and combined 6 respiratory-gates & 8 cardiac-gates projection datasets. Each dataset was reconstructed using 3D OS-EM without and with attenuation correction using the averaged and respiratory-gated attenuation maps, and the resulting reconstructed images were compared. These results were used to demonstrate the effects of R&C motions and the reduction of image artifact due to R&C motions by gating and attenuation corrections. We concluded that the realistic 4D NCAT phantom and Monte Carlo simulated SPECT projection datasets with R&C motions are powerful tools in the study of the effects of R&C motions, as well as in the development of R&C gating schemes and motion correction methods for improved SPECT/CT imaging.

Entities:  

Mesh:

Year:  2015        PMID: 25612263      PMCID: PMC4356536          DOI: 10.1088/0031-9155/60/4/1399

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  40 in total

1.  "Motion-frozen" display and quantification of myocardial perfusion.

Authors:  Piotr J Slomka; Hidetaka Nishina; Daniel S Berman; Xingping Kang; Cigdem Akincioglu; John D Friedman; Sean W Hayes; Usaf E Aladl; Guido Germano
Journal:  J Nucl Med       Date:  2004-07       Impact factor: 10.057

2.  Joint reconstruction of image and motion in gated positron emission tomography.

Authors:  Moritz Blume; Axel Martinez-Möller; Andreas Keil; Nassir Navab; Magdalena Rafecas
Journal:  IEEE Trans Med Imaging       Date:  2010-06-17       Impact factor: 10.048

3.  Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function.

Authors:  X Song; W P Segars; Y Du; B M W Tsui; E C Frey
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

4.  An investigation of the estimation of ejection fractions and cardiac volumes by a quantitative gated SPECT software package in simulated gated SPECT images.

Authors:  A D Achtert; M A King; S T Dahlberg; P H Pretorius; K J LaCroix; B M Tsui
Journal:  J Nucl Cardiol       Date:  1998 Mar-Apr       Impact factor: 5.952

5.  Comparison between the end-diastolic images and the summed images of gated 99mTc-sestamibi SPECT perfusion study in detection of coronary artery disease in women.

Authors:  R Taillefer; E G DePuey; J E Udelson; G A Beller; C Benjamin; A Gagnon
Journal:  J Nucl Cardiol       Date:  1999 Mar-Apr       Impact factor: 5.952

6.  Dual cardiac-respiratory gated PET: implementation and results from a feasibility study.

Authors:  Axel Martinez-Möller; Darko Zikic; René M Botnar; Ralph A Bundschuh; William Howe; Sibylle I Ziegler; Nassir Navab; Markus Schwaiger; Stephan G Nekolla
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-02-21       Impact factor: 9.236

7.  Quantitative analysis of the tomographic thallium-201 myocardial bullseye display: critical role of correcting for patient motion.

Authors:  R Eisner; A Churchwell; T Noever; D Nowak; K Cloninger; D Dunn; W Carlson; J Oates; J Jones; D Morris
Journal:  J Nucl Med       Date:  1988-01       Impact factor: 10.057

8.  Gated fluorine 18 fluorodeoxyglucose positron emission tomography: determination of global and regional left ventricular function and myocardial tissue characterization.

Authors:  George Saab; Robert A Dekemp; Heikki Ukkonen; Terrence D Ruddy; Guido Germano; Robert S B Beanlands
Journal:  J Nucl Cardiol       Date:  2003 May-Jun       Impact factor: 5.952

9.  Respiratory gating of cardiac PET data in list-mode acquisition.

Authors:  Lefteris Livieratos; Kim Rajappan; Lars Stegger; Klaus Schafers; Dale L Bailey; Paolo G Camici
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-01-17       Impact factor: 9.236

10.  Comparing approaches to correct for respiratory motion in NH3 PET-CT cardiac perfusion imaging.

Authors:  Paul J Schleyer; Michael J O'Doherty; Sally F Barrington; Geraint Morton; Paul K Marsden
Journal:  Nucl Med Commun       Date:  2013-12       Impact factor: 1.690

View more
  4 in total

1.  Impact of data-driven cardiac respiratory motion correction on the extent and severity of myocardial perfusion defects with free-breathing CZT SPECT.

Authors:  Doumit Daou; Rémy Sabbah; Carlos Coaguila; Hatem Boulahdour
Journal:  J Nucl Cardiol       Date:  2017-02-03       Impact factor: 5.952

2.  Gated SPECT myocardial perfusion imaging quality assurance in current and future practice.

Authors:  Kenneth J Nichols; Andrew Van Tosh
Journal:  J Nucl Cardiol       Date:  2016-12-21       Impact factor: 5.952

3.  4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT.

Authors:  Wenyuan Qi; Yongyi Yang; Chao Song; Miles N Wernick; P Hendrik Pretorius; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2017-04-04       Impact factor: 10.048

4.  Image reconstruction in higher dimensions: myocardial perfusion imaging of tracer dynamics with cardiac motion due to deformation and respiration.

Authors:  Uttam M Shrestha; Youngho Seo; Elias H Botvinick; Grant T Gullberg
Journal:  Phys Med Biol       Date:  2015-10-09       Impact factor: 3.609

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.