Literature DB >> 10327101

Comparison between the end-diastolic images and the summed images of gated 99mTc-sestamibi SPECT perfusion study in detection of coronary artery disease in women.

R Taillefer1, E G DePuey, J E Udelson, G A Beller, C Benjamin, A Gagnon.   

Abstract

BACKGROUND: End-diastolic images (EDI) can be easily derived from technetium 99m-sestamibi gated single photon emission computed tomography (SPECT) perfusion study (SGS). This may reduce the effect of myocardial wall thickening during systole and potentially improve the sensitivity of radionuclide perfusion imaging, especially in patients with small hearts.
METHODS: This prospective study was conducted in 53 consecutive female patients to compare the diagnostic accuracy of EDI with that of the summed images (SI) of SGS. Fifty-three patients with suspected coronary artery disease (CAD), scheduled for coronary angiography within 2 months, were evaluated with SGS. Treadmill stress testing was used in 28 patients, and dipyridamole injection was used in the remaining 25 patients. A 2-day protocol was used as follows: stress test with 25 to 30 mCi of 99mTc-sestamibi and a rest study performed at least 24 hours later with the same dose. Sixteen frames per cardiac cycle were acquired for both the rest and the stress studies. Three end-diastolic frames were used for EDI, and all the 16 frames were summed for SI. SI and EDI data reconstruction were interpreted by 3 experienced blinded observers (consensus reading) during two distinct reading sessions, one with SI alone and the second with EDI alone. The heart was divided into 17 segments.
RESULTS: Coronary angiography showed > or = 50% stenoses in 1 or more major coronary arteries in 38 patients and was normal in 15 patients. The sensitivity was 73.7% (28/38) and 84.2% (32/38), respectively, for SI and EDI. Three of 4 patients with CAD not detected by SI but seen with EDI were considered to have relatively small hearts. The specificity was 86.7% (13/15) and 80.0% (12/15) for SI and EDI, respectively. On a total of 901 segments, 106 ischemic defects were detected by SI and 173 by EDI (P = .001). The segmental agreement between the two techniques was 88.6% (798/901 segments).
CONCLUSION: EDI showed more ischemic defects than SI, and there was also a nonsignificant trend toward an improved sensitivity of EDI in comparison to SI in detection of coronary artery disease in women, especially in patients with small hearts. EDI may be a useful adjunct to the standard perfusion imaging with SGS in such a clinical situation.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10327101     DOI: 10.1016/s1071-3581(99)90077-6

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  18 in total

1.  Myocardial gated tomoscintigraphy with 99Tcm-methoxy-isobutyl-isonitrile (MIBI): regional and temporal activity curve analysis.

Authors:  D Grucker; P Florentz; T Oswald; J Chambron
Journal:  Nucl Med Commun       Date:  1989-10       Impact factor: 1.690

2.  Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women.

Authors:  R Taillefer; E G DePuey; J E Udelson; G A Beller; Y Latour; F Reeves
Journal:  J Am Coll Cardiol       Date:  1997-01       Impact factor: 24.094

3.  Validation of global and segmental left ventricular contractile function using gated planar technetium-99m sestamibi myocardial perfusion imaging.

Authors:  M D Tischler; J B Niggel; R W Battle; J T Fairbank; K A Brown
Journal:  J Am Coll Cardiol       Date:  1994-01       Impact factor: 24.094

4.  Simultaneous assessment of left ventricular perfusion and function with technetium-99m sestamibi after coronary artery bypass grafting.

Authors:  A E Iskandrian; J G Kegel; M A Tecce; V Wasserleben; V Cave; J Heo
Journal:  Am Heart J       Date:  1993-11       Impact factor: 4.749

5.  Left ventricular ejection fraction assessed from gated technetium-99m-sestamibi SPECT.

Authors:  E G DePuey; K Nichols; C Dobrinsky
Journal:  J Nucl Med       Date:  1993-11       Impact factor: 10.057

6.  Gated SPECT with technetium-99m-sestamibi for assessment of myocardial perfusion abnormalities.

Authors:  F Mannting; M G Morgan-Mannting
Journal:  J Nucl Med       Date:  1993-04       Impact factor: 10.057

7.  Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact.

Authors:  E G DePuey; A Rozanski
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

8.  Simultaneous assessment of left ventricular wall motion and myocardial perfusion with technetium-99m-methoxy isobutyl isonitrile at stress and rest in patients with angina: comparison with thallium-201 SPECT.

Authors:  J Villanueva-Meyer; I Mena; K A Narahara
Journal:  J Nucl Med       Date:  1990-04       Impact factor: 10.057

9.  Technetium-99m methoxy isobutyl isonitrile simultaneous evaluation of ventricular function and myocardial perfusion in patients with congenital heart disease.

Authors:  M Imbriaco; A Cuocolo; L Pace; E Nicolai; A Nappi; L Celentano; G Palma; C Vosa
Journal:  Clin Nucl Med       Date:  1994-01       Impact factor: 7.794

10.  Left ventricular ejection fraction and volumes calculated from dual gated SPECT myocardial imaging with 99Tcm-MIBI.

Authors:  K Kouris; H M Abdel-Dayem; B Taha; N Ballani; I M Hassan; C Constantinides
Journal:  Nucl Med Commun       Date:  1992-09       Impact factor: 1.690

View more
  15 in total

1.  Comparison of two three-dimensional gated SPECT methods with thallium in patients with large myocardial infarction.

Authors:  P Véra; R Koning; A Cribier; A Manrique
Journal:  J Nucl Cardiol       Date:  2000 Jul-Aug       Impact factor: 5.952

2.  Advances in SPECT camera software and hardware: currently available and new on the horizon.

Authors:  E Gordon DePuey
Journal:  J Nucl Cardiol       Date:  2012-06       Impact factor: 5.952

Review 3.  Recent developments in non-invasive cardiology.

Authors:  Sanjay K Prasad; Ravi G Assomull; Dudley J Pennell
Journal:  BMJ       Date:  2004-12-11

4.  Fourth annual Mario S. Verani, MD Memorial Lecture: noninvasive imaging in coronary artery disease: changing roles, changing players.

Authors:  Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2006-07       Impact factor: 5.952

5.  Gender differences in the diagnostic accuracy of SPECT myocardial perfusion imaging: a bivariate meta-analysis.

Authors:  Aline Iskandar; Brendan Limone; Matthew W Parker; Andrew Perugini; Hyejin Kim; Charles Jones; Brian Calamari; Craig I Coleman; Gary V Heller
Journal:  J Nucl Cardiol       Date:  2012-11-13       Impact factor: 5.952

6.  Novel SPECT Technologies and Approaches in Cardiac Imaging.

Authors:  Piotr Slomka; Guang-Uei Hung; Guido Germano; Daniel S Berman
Journal:  Cardiovasc Innov Appl       Date:  2016-12-01

7.  The influence of attenuation and scatter compensation on the apparent distribution of Tc-99m sestamibi in cardiac slices.

Authors:  P H Pretorius; M V Narayanan; S T Dahlberg; J A Leppo; M A King
Journal:  J Nucl Cardiol       Date:  2001 May-Jun       Impact factor: 5.952

8.  Lower accuracy of TI-201 SPECT in women is not improved by size-based normal databases or Wiener filtering.

Authors:  C L Hansen; M Kramer; A Rastogi
Journal:  J Nucl Cardiol       Date:  1999 Mar-Apr       Impact factor: 5.952

9.  Risk stratification with attenuation corrected stress Tc-99m sestamibi SPECT myocardial perfusion imaging in the absence of ECG-gating due to arrhythmias.

Authors:  Sarkis B Baghdasarian; Gavin L Noble; Alan W Ahlberg; Deborah Katten; Gary V Heller
Journal:  J Nucl Cardiol       Date:  2009-03-14       Impact factor: 5.952

Review 10.  Automated Quantitative Nuclear Cardiology Methods.

Authors:  Manish Motwani; Daniel S Berman; Guido Germano; Piotr Slomka
Journal:  Cardiol Clin       Date:  2015-10-20       Impact factor: 2.213

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.