Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices.

Sivakkumar Arjunon, Pablo Hidalgo Ardana, Neelakantan Saikrishnan, Shalv Madhani, Brent Foster, Ari Glezer, Ajit P Yoganathan.   

Abstract

Due to expensive nature of clinical trials, implantable cardiac devices should first be extensively characterized in vitro. Prosthetic heart valves (PHVs), an important class of these devices, have been shown to be associated with thromboembolic complications. Although various in vitro systems have been designed to quantify blood-cell damage and platelet activation caused by nonphysiological hemodynamic shear stresses in these PHVs, very few systems attempt to characterize both blood damage and fluid dynamics aspects of PHVs in the same test system. Various numerical modeling methodologies are also evolving to simulate the structural mechanics, fluid mechanics, and blood damage aspects of these devices. This article presents a completely hemocompatible small-volume test-platform that can be used for thrombogenicity studies and experimental fluid mechanics characterization. Using a programmable piston pump to drive freshly drawn human blood inside a cylindrical column, the presented system can simulate various physiological and pathophysiological conditions in testing PHVs. The system includes a modular device-mounting chamber, and in this presented case, a 23 mm St. Jude Medical (SJM) Regents® mechanical heart valve (MHV) in aortic position was used as the test device. The system was validated for its capability to quantify blood damage by measuring blood damage induced by the tester itself (using freshly drawn whole human blood). Blood damage levels were ascertained through clinically relevant assays on human blood while fluid dynamics were characterized using time-resolved particle image velocimetry (PIV) using a blood-mimicking fluid. Blood damage induced by the tester itself, assessed through Thrombin-anti-Thrombin (TAT), Prothrombin factor 1.2 (PF1.2), and hemolysis (Drabkins assay), was within clinically accepted levels. The hydrodynamic performance of the tester showed consistent, repeatable physiological pressure and flow conditions. In addition, the system contains proximity sensors to accurately capture leaflet motion during the entire cardiac cycle. The PIV results showed skewing of the leakage jet, caused by the asymmetric closing of the two leaflets. All these results are critical to characterizing the blood damage and fluid dynamics characteristics of the SJM Regents® MHV, proving the utility of this tester as a precise system for assessing the hemodynamics and thrombogenicity for various PHVs.

Entities:  

Mesh:

Year:  2015        PMID: 25587891      PMCID: PMC4347304          DOI: 10.1115/1.4029579

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  76 in total

1.  The role of whole blood in thrombin generation in contact with various titanium surfaces.

Authors:  Andreas Thor; Lars Rasmusson; Ann Wennerberg; Peter Thomsen; Jan-Michael Hirsch; Bo Nilsson; Jaan Hong
Journal:  Biomaterials       Date:  2006-11-13       Impact factor: 12.479

Review 2.  Results with mechanical cardiac valvular prostheses.

Authors:  C W Akins
Journal:  Ann Thorac Surg       Date:  1995-12       Impact factor: 4.330

3.  An in vitro model for preclinical testing of thrombogenicity of resorbable metallic stents.

Authors:  Emily K Walker; Eric A Nauman; Jean Paul Allain; Lia A Stanciu
Journal:  J Biomed Mater Res A       Date:  2014-10-21       Impact factor: 4.396

4.  Neuropsychological deficits after mechanical aortic valve replacement.

Authors:  Jennifer Uekermann; Boris Suchan; Irene Daum; Samer Kseibi; Mathias Perthel; Joachim Laas
Journal:  J Heart Valve Dis       Date:  2005-05

5.  Flow visualization of a pediatric ventricular assist device during stroke volume reductions related to weaning.

Authors:  Breigh N Roszelle; Steven Deutsch; William J Weiss; Keefe B Manning
Journal:  Ann Biomed Eng       Date:  2011-03-15       Impact factor: 3.934

6.  Functional and biocompatibility performances of an integrated Maglev pump-oxygenator.

Authors:  Tao Zhang; Guangming Cheng; Andrew Koert; Juntao Zhang; Barry Gellman; G Kwame Yankey; Aditee Satpute; Kurt A Dasse; Richard J Gilbert; Bartley P Griffith; Zhongjun J Wu
Journal:  Artif Organs       Date:  2009-01       Impact factor: 3.094

7.  Initiation of platelet adhesion by arrest onto fibrinogen or translocation on von Willebrand factor.

Authors:  B Savage; E Saldívar; Z M Ruggeri
Journal:  Cell       Date:  1996-01-26       Impact factor: 41.582

Review 8.  Thromboembolic and bleeding complications in patients with mechanical heart valve prostheses.

Authors:  S C Cannegieter; F R Rosendaal; E Briët
Journal:  Circulation       Date:  1994-02       Impact factor: 29.690

9.  Evaluation of shear-induced platelet activation models under constant and dynamic shear stress loading conditions relevant to devices.

Authors:  Jawaad Sheriff; João Silva Soares; Michalis Xenos; Jolyon Jesty; Marvin J Slepian; Danny Bluestein
Journal:  Ann Biomed Eng       Date:  2013-02-12       Impact factor: 3.934

10.  New stent surface materials: the impact of polymer-dependent interactions of human endothelial cells, smooth muscle cells, and platelets.

Authors:  Raila Busch; Anne Strohbach; Stefanie Rethfeldt; Simon Walz; Mathias Busch; Svea Petersen; Stephan Felix; Katrin Sternberg
Journal:  Acta Biomater       Date:  2013-10-19       Impact factor: 8.947

View more
  5 in total

1.  Three-dimensional extent of flow stagnation in transcatheter heart valves.

Authors:  Vrishank Raghav; Chris Clifford; Prem Midha; Ikechukwu Okafor; Brian Thurow; Ajit Yoganathan
Journal:  J R Soc Interface       Date:  2019-05-31       Impact factor: 4.118

Review 2.  In Vitro models for thrombogenicity testing of blood-recirculating medical devices.

Authors:  Deepika N Sarode; Shuvo Roy
Journal:  Expert Rev Med Devices       Date:  2019-06-10       Impact factor: 3.166

3.  Integrated strategy for in vitro characterization of a bileaflet mechanical aortic valve.

Authors:  Francesca Maria Susin; Stefania Espa; Riccardo Toninato; Stefania Fortini; Giorgio Querzoli
Journal:  Biomed Eng Online       Date:  2017-02-16       Impact factor: 2.819

4.  Hydrodynamic Noise of Pulsating Jets through Bileaflet Mechanical Mitral Valve.

Authors:  Vladimir Voskoboinick; Oleksandr Voskoboinyk; Oleg Chertov; Andrey Voskoboinick; Lidiia Tereshchenko
Journal:  Biomed Res Int       Date:  2020-05-30       Impact factor: 3.411

5.  A Single-opening&closing Valve Tester for Direct Measurement of Closing Volume of the Heart Valve.

Authors:  Hao Wang; Zhan Cui; Zhongxi Zhou; Zhaoming He
Journal:  Cardiovasc Eng Technol       Date:  2021-06-25       Impact factor: 2.495

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.