Literature DB >> 8787503

Results with mechanical cardiac valvular prostheses.

C W Akins1.   

Abstract

Mechanical cardiac valvular prostheses continue to be more popular than bioprostheses for heart valve replacement operations. Five different brands of mechanical heart valves are now approved for implantation in the United States: Starr-Edwards models 1260 and 6120, Medtronic-Hall, St. Jude Medical, Omniscience, and CarboMedics. Each model of mechanical valve has certain positive and negative attributes, but none is functionally mechanically perfect. A review of the published long term results with these valves favors the Medtronic-Hall and St. Jude Medical valves. A new method of assessing the thrombogenic potential and requirement for anticoagulation of the different mechanical valves, namely the composite thromboembolism and bleeding index, is proposed. Evaluation of the new index demonstrates a modest advantage for the Medtronic-Hall valve, particularly in the aortic position.

Entities:  

Mesh:

Year:  1995        PMID: 8787503     DOI: 10.1016/0003-4975(95)00766-0

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  9 in total

1.  Listen to your heart.

Authors:  Iacopo Bertolozzi; Angelo Pucci; Pietro Amedeo Modesti
Journal:  Intern Emerg Med       Date:  2009-02-19       Impact factor: 3.397

2.  St. Jude Medical and CarboMedics mechanical heart valves in the aortic position: comparison of long-term results.

Authors:  Ozer Kandemir; Hilmi Tokmakoglu; Ulku Yildiz; Tevfik Tezcaner; A Cem Yorgancioglu; Lihan Gunay; Kaya Suzer; Yaman Zorlutuna
Journal:  Tex Heart Inst J       Date:  2006

3.  Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices.

Authors:  Sivakkumar Arjunon; Pablo Hidalgo Ardana; Neelakantan Saikrishnan; Shalv Madhani; Brent Foster; Ari Glezer; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2015-02-11       Impact factor: 2.097

4.  Numerical investigation of the performance of three hinge designs of bileaflet mechanical heart valves.

Authors:  Hélène A Simon; Liang Ge; Fotis Sotiropoulos; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2010-06-23       Impact factor: 3.934

5.  Role of Computational Simulations in Heart Valve Dynamics and Design of Valvular Prostheses.

Authors:  Krishnan B Chandran
Journal:  Cardiovasc Eng Technol       Date:  2010-03       Impact factor: 2.495

6.  High-shear stress sensitizes platelets to subsequent low-shear conditions.

Authors:  Jawaad Sheriff; Danny Bluestein; Gaurav Girdhar; Jolyon Jesty
Journal:  Ann Biomed Eng       Date:  2010-02-05       Impact factor: 3.934

Review 7.  Advances in the management of severe aortic stenosis.

Authors:  K E O'Sullivan; S Bargenda; D Sugrue; J Hurley
Journal:  Ir J Med Sci       Date:  2016-02-17       Impact factor: 1.568

8.  Short-Term Clinical Follow-Up After Thrombolytic Therapy in Patients With Prosthetic Valve Thrombosis: A Single-Center Experience.

Authors:  Akshyaya Pradhan; Monika Bhandari; Vikas Gupta; Pravesh Vishwakarma; Rishi Sethi; Varun Shankar Narain; Gaurav Chaudhary; Sharad Chandra; Sudhanshu Dwivedi
Journal:  Cardiol Res       Date:  2019-11-24

9.  Self-management of patients with heart valve replacement and its clinical outcomes: a systematic review.

Authors:  Shirdel Zandi; Behzad Imani; Gholamreza Safarpor; Salman Khazaei
Journal:  Kardiochir Torakochirurgia Pol       Date:  2021-05-15
  9 in total