A Single-opening&closing Valve Tester for Direct Measurement of Closing Volume of the Heart Valve.

Hao Wang1, Zhan Cui1, Zhongxi Zhou1, Zhaoming He2.   

Abstract

PURPOSE: The objective of this study was to develop a novel single opening&closing pulsatile flow in-vitro valve tester for direct measurement of closing volume of the heart valve.
METHODS: A single opening&closing valve tester was composed of a piston pump, valve mounting chamber, reservoir, measurement and control system. The piston pump was used to drive a valve to open and close with dictated flow which comprised three phases of accelerated, constant, and decelerated flow with six slopes. A high speed camera was used to record valve opening and closing images. Two pressure transducers across the tested valve were used to capture the ending time of valve closing which was verified by the high-speed photography. The closing time was measured and closing volume was calculated with a piston displacement volume during valve closing. A tilting disc valve and porcine mitral valve were tested.
RESULTS: There was a big difference in flowrate between the Transonic flowmeter and piston pump. The heart valve opened and closed under the dictated flow driven by the piston pump. The transvalvular pressure was minor during valve opening and then increased sharply during valve closing. The closing time varied approximately linearly with the slope of the decelerated flow and was comparable between the two methods by the transvalvular pressure and high-speed photography. The closing volumes did not change much with the slope of the decelerated flow and were 7.0 ± 1.0 and 14.0 ± 1.5 mL for the tilting disc valve and mitral valve, respectively.
CONCLUSION: Pulsatile flow is challenging to the flowmeter. A novel single opening&closing pulsatile flow in-vitro valve tester for the heart valve has successfully been developed and can be used to simulate and evaluate the opening and closing hemodynamics of the heart valve. The tester can be used to measure valve closing volume and time accurately with a standardized testing protocol free from effect of other components such as the resistance, compliance units and auxiliary valve in the continuous pulsatile flow valve tester.
© 2021. Biomedical Engineering Society.

Entities:  

Keywords:  Heart valve; Regurgitation; Replacement and repair; Standardized pulsatile tester

Mesh:

Year:  2021        PMID: 34173164     DOI: 10.1007/s13239-021-00560-9

Source DB:  PubMed          Journal:  Cardiovasc Eng Technol        ISSN: 1869-408X            Impact factor:   2.495


  37 in total

1.  Transit time flow measurement: experimental validation and comparison of three different systems.

Authors:  G Beldi; A Bosshard; O M Hess; U Althaus; B H Walpoth
Journal:  Ann Thorac Surg       Date:  2000-07       Impact factor: 4.330

2.  Passive flow control of bileaflet mechanical heart valve leakage flow.

Authors:  Lakshmi P Dasi; David W Murphy; Ari Glezer; Ajit P Yoganathan
Journal:  J Biomech       Date:  2008-03-28       Impact factor: 2.712

3.  Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices.

Authors:  Sivakkumar Arjunon; Pablo Hidalgo Ardana; Neelakantan Saikrishnan; Shalv Madhani; Brent Foster; Ari Glezer; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2015-02-11       Impact factor: 2.097

Review 4.  Transcatheter Tricuspid Valve Interventions: An Emerging Field.

Authors:  Livia Gheorghe; Benno J W M Rensing; Jan A S Van der Heyden; Frank D Eefting; Martijn C Post; Bushra Rana; Martin J Swaans
Journal:  Curr Cardiol Rep       Date:  2019-03-28       Impact factor: 2.931

5.  Validation of a numerical FSI simulation of an aortic BMHV by in vitro PIV experiments.

Authors:  S Annerel; T Claessens; J Degroote; P Segers; J Vierendeels
Journal:  Med Eng Phys       Date:  2014-06-10       Impact factor: 2.242

6.  Effects of annular contraction on anterior leaflet strain using an in vitro simulator with a dynamically contracting mitral annulus.

Authors:  Thomas F Easley; Charles H Bloodworth; Vinay Bhal; Ajit P Yoganathan
Journal:  J Biomech       Date:  2017-11-21       Impact factor: 2.712

7.  Surface Strains of Porcine Tricuspid Valve Septal Leaflets Measured in Ex Vivo Beating Hearts.

Authors:  Keyvan Amini Khoiy; Dipankar Biswas; Thomas N Decker; Kourosh T Asgarian; Francis Loth; Rouzbeh Amini
Journal:  J Biomech Eng       Date:  2016-11-01       Impact factor: 2.097

8.  Ex Vivo Methods for Informing Computational Models of the Mitral Valve.

Authors:  Charles H Bloodworth; Eric L Pierce; Thomas F Easley; Andrew Drach; Amir H Khalighi; Milan Toma; Morten O Jensen; Michael S Sacks; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2016-10-03       Impact factor: 3.934

9.  Transcatheter interventions for functional mitral regurgitation.

Authors:  William Z Chancellor; Sarah A Schubert; Gorav Ailawadi
Journal:  Ann Cardiothorac Surg       Date:  2018-11

10.  Dilation of tricuspid valve annulus immediately after rupture of chordae tendineae in ex-vivo porcine hearts.

Authors:  Keyvan Amini Khoiy; Kourosh T Asgarian; Francis Loth; Rouzbeh Amini
Journal:  PLoS One       Date:  2018-11-08       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.