Literature DB >> 25585394

Multi-frequency intravascular ultrasound (IVUS) imaging.

Teng Ma, Mingyue Yu, Jiawen Li, Chelsea E Munding, Zeyu Chen, Chunlong Fei, K Kirk Shung, Qifa Zhou.   

Abstract

Acute coronary syndrome (ACS) is frequently associated with the sudden rupture of a vulnerable atherosclerotic plaque within the coronary artery. Several unique physiological features, including a thin fibrous cap accompanied by a necrotic lipid core, are the targeted indicators for identifying the vulnerable plaques. Intravascular ultrasound (IVUS), a catheter-based imaging technology, has been routinely performed in clinics for more than 20 years to describe the morphology of the coronary artery and guide percutaneous coronary interventions. However, conventional IVUS cannot facilitate the risk assessment of ACS because of its intrinsic limitations, such as insufficient resolution. Renovation of the IVUS technology is essentially needed to overcome the limitations and enhance the coronary artery characterization. In this paper, a multi-frequency intravascular ultrasound (IVUS) imaging system was developed by incorporating a higher frequency IVUS transducer (80 to 150 MHz) with the conventional IVUS (30-50 MHz) system. The newly developed system maintains the advantage of deeply penetrating imaging with the conventional IVUS, while offering an improved higher resolution image with IVUS at a higher frequency. The prototyped multifrequency catheter has a clinically compatible size of 0.95 mm and a favorable capability of automated image co-registration. In vitro human coronary artery imaging has demonstrated the feasibility and superiority of the multi-frequency IVUS imaging system to deliver a more comprehensive visualization of the coronary artery. This ultrasonic-only intravascular imaging technique, based on a moderate refinement of the conventional IVUS system, is not only cost-effective from the perspective of manufacturing and clinical practice, but also holds the promise of future translation into clinical benefits.

Entities:  

Mesh:

Year:  2015        PMID: 25585394      PMCID: PMC4522164          DOI: 10.1109/TUFFC.2014.006679

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  30 in total

Review 1.  Advances in ultrasound biomicroscopy.

Authors:  F S Foster; C J Pavlin; K A Harasiewicz; D A Christopher; D H Turnbull
Journal:  Ultrasound Med Biol       Date:  2000-01       Impact factor: 2.998

Review 2.  Tissue characterisation using intravascular radiofrequency data analysis: recommendations for acquisition, analysis, interpretation and reporting.

Authors:  Héctor M García-García; Gary S Mintz; Amir Lerman; D Geoffrey Vince; M Paulina Margolis; Gerrit-Anne van Es; Marie-Angèle M Morel; Anuja Nair; Renu Virmani; Allen P Burke; Gregg W Stone; Patrick W Serruys
Journal:  EuroIntervention       Date:  2009-06       Impact factor: 6.534

3.  Assessing atherosclerotic plaque morphology: comparison of optical coherence tomography and high frequency intravascular ultrasound.

Authors:  M E Brezinski; G J Tearney; N J Weissman; S A Boppart; B E Bouma; M R Hee; A E Weyman; E A Swanson; J F Southern; J G Fujimoto
Journal:  Heart       Date:  1997-05       Impact factor: 5.994

Review 4.  Hybrid intravascular imaging: current applications and prospective potential in the study of coronary atherosclerosis.

Authors:  Christos V Bourantas; Hector M Garcia-Garcia; Katerina K Naka; Antonios Sakellarios; Lambros Athanasiou; Dimitrios I Fotiadis; Lampros K Michalis; Patrick W Serruys
Journal:  J Am Coll Cardiol       Date:  2013-04-02       Impact factor: 24.094

5.  Evaluation of four-year coronary artery response after sirolimus-eluting stent implantation using serial quantitative intravascular ultrasound and computer-assisted grayscale value analysis for plaque composition in event-free patients.

Authors:  Jiro Aoki; Alexandre C Abizaid; Patrick W Serruys; Andrew T L Ong; Eric Boersma; J Eduardo Sousa; Nico Bruining
Journal:  J Am Coll Cardiol       Date:  2005-10-10       Impact factor: 24.094

6.  PMN-PT single crystal, high-frequency ultrasonic needle transducers for pulsed-wave Doppler application.

Authors:  Qifa Zhou; Xiaochen Xu; Emanuel J Gottlieb; Lei Sun; Jonathan M Cannata; Hossein Ameri; Mark S Humayun; Pengdi Han; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-03       Impact factor: 2.725

7.  80-MHz intravascular ultrasound transducer using PMN-PT free-standing film.

Authors:  Xiang Li; Wei Wu; Youngsoo Chung; Wan Y Shih; Wei-Heng Shih; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-11       Impact factor: 2.725

8.  Coronary artery imaging with intravascular high-frequency ultrasound.

Authors:  B N Potkin; A L Bartorelli; J M Gessert; R F Neville; Y Almagor; W C Roberts; M B Leon
Journal:  Circulation       Date:  1990-05       Impact factor: 29.690

9.  Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications.

Authors:  Jonathan M Cannata; Timothy A Ritter; Wo-Hsing Chen; Ronald H Silverman; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

10.  Micromachined PIN-PMN-PT crystal composite transducer for high-frequency intravascular ultrasound (IVUS) imaging.

Authors:  Xiang Li; Teng Ma; Jian Tian; Pengdi Han; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-07       Impact factor: 2.725

View more
  24 in total

1.  Dual-element needle transducer for intravascular ultrasound imaging.

Authors:  Sangpil Yoon; Min Gon Kim; Jay A Williams; Changhan Yoon; Bong Jin Kang; Nestor Cabrera-Munoz; K Kirk Shung; Hyung Ham Kim
Journal:  J Med Imaging (Bellingham)       Date:  2015-04-13

2.  Optimal flushing agents for integrated optical and acoustic imaging systems.

Authors:  Jiawen Li; Hataka Minami; Earl Steward; Teng Ma; Dilbahar Mohar; Claire Robertson; Kirk Shung; Qifa Zhou; Pranav Patel; Zhongping Chen
Journal:  J Biomed Opt       Date:  2015-05       Impact factor: 3.170

3.  Analysis and Design of High-Frequency 1-D CMUT Imaging Arrays in Noncollapsed Mode.

Authors:  Evren Fatih Arkan; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-17       Impact factor: 2.725

4.  (100)-Textured KNN-based thick film with enhanced piezoelectric property for intravascular ultrasound imaging.

Authors:  Benpeng Zhu; Zhiqiang Zhang; Teng Ma; Xiaofei Yang; Yongxiang Li; K Kirk Shung; Qifa Zhou
Journal:  Appl Phys Lett       Date:  2015-04-28       Impact factor: 3.791

5.  Intravascular Ultrasound Imaging With Virtual Source Synthetic Aperture Focusing and Coherence Factor Weighting.

Authors:  Mingyue Yu; Yang Li; Teng Ma; K Kirk Shung; Qifa Zhou
Journal:  IEEE Trans Med Imaging       Date:  2017-07-04       Impact factor: 10.048

6.  High contrast power Doppler imaging in side-viewing intravascular ultrasound imaging via angular compounding.

Authors:  Graham C Collins; Bowen Jing; Brooks D Lindsey
Journal:  Ultrasonics       Date:  2020-06-02       Impact factor: 2.890

7.  Two-Point Stretchable Electrode Array for Endoluminal Electrochemical Impedance Spectroscopy Measurements of Lipid-Laden Atherosclerotic Plaques.

Authors:  René R Sevag Packard; XiaoXiao Zhang; Yuan Luo; Teng Ma; Nelson Jen; Jianguo Ma; Linda L Demer; Qifa Zhou; James W Sayre; Rongsong Li; Yu-Chong Tai; Tzung K Hsiai
Journal:  Ann Biomed Eng       Date:  2016-02-08       Impact factor: 3.934

Review 8.  A Review of Intravascular Ultrasound-based Multimodal Intravascular Imaging: The Synergistic Approach to Characterizing Vulnerable Plaques.

Authors:  Teng Ma; Bill Zhou; Tzung K Hsiai; K Kirk Shung
Journal:  Ultrason Imaging       Date:  2015-09-22       Impact factor: 1.578

Review 9.  Mechanically Rotating Intravascular Ultrasound (IVUS) Transducer: A Review.

Authors:  Jin-Ho Sung; Jin-Ho Chang
Journal:  Sensors (Basel)       Date:  2021-06-05       Impact factor: 3.576

10.  High-speed intravascular photoacoustic imaging at 1.7 μm with a KTP-based OPO.

Authors:  Jie Hui; Qianhuan Yu; Teng Ma; Pu Wang; Yingchun Cao; Rebecca S Bruning; Yueqiao Qu; Zhongping Chen; Qifa Zhou; Michael Sturek; Ji-Xin Cheng; Weibiao Chen
Journal:  Biomed Opt Express       Date:  2015-10-23       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.