Literature DB >> 25991874

(100)-Textured KNN-based thick film with enhanced piezoelectric property for intravascular ultrasound imaging.

Benpeng Zhu, Zhiqiang Zhang1, Teng Ma2, Xiaofei Yang3, Yongxiang Li1, K Kirk Shung2, Qifa Zhou2.   

Abstract

Using tape-casting technology, 35 μm free-standing (100)-textured Li doped KNN (KNLN) thick film was prepared by employing NaNbO3 (NN) as template. It exhibited similar piezoelectric behavior to lead containing materials: a longitudinal piezoelectric coefficient (d33) of ∼150 pm/V and an electromechanical coupling coefficient (kt ) of 0.44. Based on this thick film, a 52 MHz side-looking miniature transducer with a bandwidth of 61.5% at -6 dB was built for Intravascular ultrasound (IVUS) imaging. In comparison with 40 MHz PMN-PT single crystal transducer, the rabbit aorta image had better resolution and higher noise-to-signal ratio, indicating that lead-free (100)-textured KNLN thick film may be suitable for IVUS (>50 MHz) imaging.

Entities:  

Year:  2015        PMID: 25991874      PMCID: PMC4417015          DOI: 10.1063/1.4919387

Source DB:  PubMed          Journal:  Appl Phys Lett        ISSN: 0003-6951            Impact factor:   3.791


  7 in total

Review 1.  Intravascular ultrasound: novel pathophysiological insights and current clinical applications.

Authors:  S E Nissen; P Yock
Journal:  Circulation       Date:  2001-01-30       Impact factor: 29.690

2.  Correlation between high frequency intravascular ultrasound and histomorphology in human coronary arteries.

Authors:  F Prati; E Arbustini; A Labellarte; B Dal Bello; L Sommariva; M T Mallus; A Pagano; A Boccanelli
Journal:  Heart       Date:  2001-05       Impact factor: 5.994

3.  Systematic study of high-frequency ultrasonic transducer design for laser-scanning photoacoustic ophthalmoscopy.

Authors:  Teng Ma; Xiangyang Zhang; Chi Tat Chiu; Ruimin Chen; K Kirk Shung; Qifa Zhou; Shuliang Jiao
Journal:  J Biomed Opt       Date:  2014-01       Impact factor: 3.170

4.  Multi-frequency intravascular ultrasound (IVUS) imaging.

Authors:  Teng Ma; Mingyue Yu; Jiawen Li; Chelsea E Munding; Zeyu Chen; Chunlong Fei; K Kirk Shung; Qifa Zhou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-01       Impact factor: 2.725

5.  80-MHz intravascular ultrasound transducer using PMN-PT free-standing film.

Authors:  Xiang Li; Wei Wu; Youngsoo Chung; Wan Y Shih; Wei-Heng Shih; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-11       Impact factor: 2.725

6.  Micromachined PIN-PMN-PT crystal composite transducer for high-frequency intravascular ultrasound (IVUS) imaging.

Authors:  Xiang Li; Teng Ma; Jian Tian; Pengdi Han; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-07       Impact factor: 2.725

7.  Miniature optical coherence tomography-ultrasound probe for automatically coregistered three-dimensional intracoronary imaging with real-time display.

Authors:  Jiawen Li; Teng Ma; Joseph Jing; Jun Zhang; Pranav M Patel; K Kirk Shung; Qifa Zhou; Zhongping Chen
Journal:  J Biomed Opt       Date:  2013-10       Impact factor: 3.170

  7 in total
  8 in total

1.  Substantially Enhanced Properties of 2D WS2 by High Concentration of Erbium Doping against Tungsten Vacancy Formation.

Authors:  Hongquan Zhao; Guoxing Zhang; Bing Yan; Bo Ning; Chunxiang Wang; Yang Zhao; Xuan Shi
Journal:  Research (Wash D C)       Date:  2022-07-04

2.  New Potassium Sodium Niobate Single Crystal with Thickness-independent High-performance for Photoacoustic Angiography of Atherosclerotic Lesion.

Authors:  Benpeng Zhu; Yuhang Zhu; Jie Yang; Jun Ou-Yang; Xiaofei Yang; Yongxiang Li; Wei Wei
Journal:  Sci Rep       Date:  2016-12-21       Impact factor: 4.379

3.  Fabrication and Characterization of High-Frequency Ultrasound Transducers Based on Lead-Free BNT-BT Tape-Casting Thick Film.

Authors:  Junshan Zhang; Wei Ren; Yantao Liu; Xiaoqing Wu; Chunlong Fei; Yi Quan; Qifa Zhou
Journal:  Sensors (Basel)       Date:  2018-09-19       Impact factor: 3.576

4.  PIN-PMN-PT Single Crystal 1-3 Composite-based 20 MHz Ultrasound Phased Array.

Authors:  Wei Zhou; Tao Zhang; Jun Ou-Yang; Xiaofei Yang; Dawei Wu; Benpeng Zhu
Journal:  Micromachines (Basel)       Date:  2020-05-21       Impact factor: 2.891

5.  Screen Printed Copper and Tantalum Modified Potassium Sodium Niobate Thick Films on Platinized Alumina Substrates.

Authors:  Brigita Kmet; Danjela Kuščer; Soma Dutta; Hana Uršič; Aleksander Matavž; Franck Levassort; Vid Bobnar; Barbara Malič; Andreja Benčan
Journal:  Materials (Basel)       Date:  2021-11-24       Impact factor: 3.623

6.  Nb and Mn Co-Modified Na0.5Bi4.5Ti4O15 Bismuth-Layered Ceramics for High-Frequency Transducer Applications.

Authors:  Dongming Fan; Huiyan Niu; Kun Liu; Xinhao Sun; Husheng Wang; Kefei Shi; Wen Mo; Zhishui Jian; Li Wen; Meng Shen; Tianlong Zhao; Chunlong Fei; Yong Chen
Journal:  Micromachines (Basel)       Date:  2022-08-02       Impact factor: 3.523

Review 7.  Recent Advances in Transducers for Intravascular Ultrasound (IVUS) Imaging.

Authors:  Chang Peng; Huaiyu Wu; Seungsoo Kim; Xuming Dai; Xiaoning Jiang
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.847

8.  Transferred PMN-PT Thick Film on Conductive Silver Epoxy.

Authors:  Tao Zhang; Jun Ou-Yang; Xiaofei Yang; Benpeng Zhu
Journal:  Materials (Basel)       Date:  2018-09-05       Impact factor: 3.623

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.