Literature DB >> 25571403

Design and development of a mobile image overlay system for needle interventions.

M Anand, F King, T Ungi, A Lasso, J Rudan, J Jayender, J Fritz, J A Carrino, F A Jolesz, G Fichtinger.   

Abstract

Previously, a static and adjustable image overlay systems were proposed for aiding needle interventions. The system was either fixed to a scanner or mounted over a large articulated counterbalanced arm. Certain drawbacks associated with these systems limited the clinical translation. In order to minimize these limitations, we present the mobile image overlay system with the objective of reduced system weight, smaller dimension, and increased tracking accuracy. The design study includes optimal workspace definition, selection of display device, mirror, and laser source. The laser plane alignment, phantom design, image overlay plane calibration, and system accuracy validation methods are discussed. The virtual image is generated by a tablet device and projected into the patient by using a beamsplitter mirror. The viewbox weight (1.0 kg) was reduced by 8.2 times and image overlay plane tracking precision (0.21 mm, STD = 0.05) was improved by 5 times compared to previous system. The automatic self-calibration of the image overlay plane was achieved in two simple steps and can be done away from patient table. The fiducial registration error of the physical phantom to scanned image volume registration was 1.35 mm (STD = 0.11). The reduced system weight and increased accuracy of optical tracking should enable the system to be hand held by the physician and explore the image volume over the patient for needle interventions.

Entities:  

Mesh:

Year:  2014        PMID: 25571403      PMCID: PMC4437519          DOI: 10.1109/EMBC.2014.6945035

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  7 in total

1.  Overlaying ultrasonographic images on direct vision.

Authors:  G D Stetten; V S Chib
Journal:  J Ultrasound Med       Date:  2001-03       Impact factor: 2.153

2.  Stereotactic localization of breast lesions: how it works and methods to improve accuracy.

Authors:  J J Carr; P F Hemler; P W Halford; R I Freimanis; R H Choplin; M Y Chen
Journal:  Radiographics       Date:  2001 Mar-Apr       Impact factor: 5.333

3.  Image overlay guidance for needle insertion in CT scanner.

Authors:  Gabor Fichtinger; Anton Deguet; Ken Masamune; Emese Balogh; Gregory S Fischer; Herve Mathieu; Russell H Taylor; S James Zinreich; Laura M Fayad
Journal:  IEEE Trans Biomed Eng       Date:  2005-08       Impact factor: 4.538

Review 4.  MRI image overlay: application to arthrography needle insertion.

Authors:  Gregory S Fischer; Anton Deguet; Csaba Csoma; Russell H Taylor; Laura Fayad; John A Carrino; S James Zinreich; Gabor Fichtinger
Journal:  Comput Aided Surg       Date:  2007-01

5.  Source placement error for permanent implant of the prostate.

Authors:  P L Roberson; V Narayana; D L McShan; R J Winfield; P W McLaughlin
Journal:  Med Phys       Date:  1997-02       Impact factor: 4.071

6.  Augmented reality visualization with use of image overlay technology for MR imaging-guided interventions: assessment of performance in cadaveric shoulder and hip arthrography at 1.5 T.

Authors:  Jan Fritz; Paweena U-Thainual; Tamas Ungi; Aaron J Flammang; Gabor Fichtinger; Iulian I Iordachita; John A Carrino
Journal:  Radiology       Date:  2012-07-27       Impact factor: 11.105

7.  Augmented reality visualisation using an image overlay system for MR-guided interventions: technical performance of spine injection procedures in human cadavers at 1.5 Tesla.

Authors:  Jan Fritz; Paweena U-Thainual; Tamas Ungi; Aaron J Flammang; Gabor Fichtinger; Iulian I Iordachita; John A Carrino
Journal:  Eur Radiol       Date:  2012-07-15       Impact factor: 5.315

  7 in total
  3 in total

1.  1.5 T augmented reality navigated interventional MRI: paravertebral sympathetic plexus injections.

Authors:  David R Marker; Paweena U Thainual; Tamas Ungi; Aaron J Flammang; Gabor Fichtinger; Iulian I Iordachita; John A Carrino; Jan Fritz
Journal:  Diagn Interv Radiol       Date:  2017 May-Jun       Impact factor: 2.630

2.  New simple image overlay system using a tablet PC for pinpoint identification of the appropriate site for anastomosis in peripheral arterial reconstruction.

Authors:  Yasuaki Mochizuki; Akihiro Hosaka; Hiroki Kamiuchi; Jun Xiao Nie; Ken Masamune; Katsuyuki Hoshina; Tetsuro Miyata; Toshiaki Watanabe
Journal:  Surg Today       Date:  2016-03-17       Impact factor: 2.549

Review 3.  MRI-guided sacroiliac joint injections in children and adults: current practice and future developments.

Authors:  Danoob Dalili; Amanda Isaac; Jan Fritz
Journal:  Skeletal Radiol       Date:  2022-08-25       Impact factor: 2.128

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.