Source placement error for permanent implant of the prostate.

P L Roberson1, V Narayana, D L McShan, R J Winfield, P W McLaughlin.   

Abstract

The performance of ultrasound (US) and fluoroscopic-guided permanent 125I source implant of the prostate using CT identification of the source positions has been evaluated. Marker seeds were implanted during the planning study to assist in the alignment of the US and CT prostate volumes for treatment planning and to guide the placement of needles. The relative positions of the needles and marker seeds were checked by fluoroscopy. A postimplant CT study was used to input the radioactive source positions and to register the sources relative to the preimplant CT and US prostate volumes and the planned source distribution. Source placement errors observed were categorized as: (1) source-to-source spacing differences; (2) needle placement error, both depth and position; and (3) seed splaying, particularly near the prostate periphery. Errors due to source splaying and spacing were in part attributed to prostate motion. Later refinements included fixed-spaced string sources, for which placement errors were smaller than for unattached sources. However, source placement errors due to needle placement error and prostate motion remained unchanged.

Mesh:

Substances:

Year:  1997        PMID: 9048365     DOI: 10.1118/1.598058

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  Robotic needle guide for prostate brachytherapy: clinical testing of feasibility and performance.

Authors:  Danny Y Song; Everette C Burdette; Jonathan Fiene; Elwood Armour; Gernot Kronreif; Anton Deguet; Zhe Zhang; Iulian Iordachita; Gabor Fichtinger; Peter Kazanzides
Journal:  Brachytherapy       Date:  2010-08-21       Impact factor: 2.362

2.  Magnetic resonance imaging compatible robotic system for fully automated brachytherapy seed placement.

Authors:  Michael Muntener; Alexandru Patriciu; Doru Petrisor; Dumitru Mazilu; Herman Bagga; Louis Kavoussi; Kevin Cleary; Dan Stoianovici
Journal:  Urology       Date:  2006-12       Impact factor: 2.649

3.  Permanent prostate brachytherapy: the significance of postimplant dosimetry.

Authors:  W Robert Lee
Journal:  Rev Urol       Date:  2004

4.  Transurethral light delivery for prostate photoacoustic imaging.

Authors:  Muyinatu A Lediju Bell; Xiaoyu Guo; Danny Y Song; Emad M Boctor
Journal:  J Biomed Opt       Date:  2015-03       Impact factor: 3.170

5.  Design and development of a mobile image overlay system for needle interventions.

Authors:  M Anand; F King; T Ungi; A Lasso; J Rudan; J Jayender; J Fritz; J A Carrino; F A Jolesz; G Fichtinger
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

6.  Investigating the dosimetric and tumor control consequences of prostate seed loss and migration.

Authors:  Courtney Knaup; Panayiotis Mavroidis; Carlos Esquivel; Sotirios Stathakis; Gregory Swanson; Dimos Baltas; Nikos Papanikolaou
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

7.  Towards Automatic Robotic Calibration System for Flexible Needles with FBG Sensors.

Authors:  Kefan Song; Dimitri A Lezcano; Ge Sun; Jin Seob Kim; Iulian I Iordachita
Journal:  Int Symp Med Robot       Date:  2021-11

8.  Quantification of edematic effects in prostate brachytherapy interventions.

Authors:  Mohamed Hefny; Purang Abolmaesumi; Zahra Karimaghaloo; David G Gobbi; Randy Ellis; Gabor Fichtinger
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

9.  CT-guided iodine-125 brachytherapy as salvage therapy for recurrent mediastinal lymph node metastasis.

Authors:  Hong Dong; Lin Li; Dianjin Xing; Yuliang Li; Wujie Wang
Journal:  Thorac Cancer       Date:  2021-03-14       Impact factor: 3.500

10.  Impact of edema and seed movement on the dosimetry of prostate seed implants.

Authors:  Ron S Sloboda; N Usmani; T T Monajemi; D M-C Liu
Journal:  J Med Phys       Date:  2012-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.