Literature DB >> 11259709

Stereotactic localization of breast lesions: how it works and methods to improve accuracy.

J J Carr1, P F Hemler, P W Halford, R I Freimanis, R H Choplin, M Y Chen.   

Abstract

A computer simulation of stereotactic breast biopsy was developed that paralleled the geometric configuration of a currently available breast biopsy system. This model was developed to define and improve the targeting of breast lesions with stereotactic biopsy techniques. Lesions must be clearly identified and accurately targeted on both views for successful localization. Nonvisualization of a lesion may result from overlying tissue or from the geometric configuration of the imaging system. Familiarity with the geometric configuration of the biopsy unit, especially the location of the reference point and center of rotation, facilitates understanding of apparent changes in lesion position (parallax shift). Inaccuracy in lesion targeting on one or both views will manifest predominantly as an error in the calculated z value (depth). The magnitude and direction of this error are largely determined by the direction of the targeting error. Compensatory strategies include use of a long-throw core biopsy gun or directional vacuum-assisted biopsy device and additional sampling along the z axis and should be accompanied by critical evaluation of both pre- and postfire images. Understanding geometric considerations as well as how targeting accuracy affects accuracy in lesion localization should lead to greater success in sampling even challenging breast lesions at stereotactic biopsy.

Entities:  

Mesh:

Year:  2001        PMID: 11259709     DOI: 10.1148/radiographics.21.2.g01mr11463

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  5 in total

1.  Robust path planning for flexible needle insertion using Markov decision processes.

Authors:  Xiaoyu Tan; Pengqian Yu; Kah-Bin Lim; Chee-Kong Chui
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-05-11       Impact factor: 2.924

2.  Does needle rotation improve lesion targeting?

Authors:  Shadi Badaan; Doru Petrisor; Chunwoo Kim; Pierre Mozer; Dumitru Mazilu; Lucian Gruionu; Alex Patriciu; Kevin Cleary; Dan Stoianovici
Journal:  Int J Med Robot       Date:  2011-03-01       Impact factor: 2.547

3.  Design and development of a mobile image overlay system for needle interventions.

Authors:  M Anand; F King; T Ungi; A Lasso; J Rudan; J Jayender; J Fritz; J A Carrino; F A Jolesz; G Fichtinger
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

Review 4.  Stereotactic breast biopsy: A review & applicability in the Indian context.

Authors:  Suma Chakrabarthi
Journal:  Indian J Med Res       Date:  2021-08       Impact factor: 5.274

5.  Accuracy evaluation of a 3D-printed individual template for needle guidance in head and neck brachytherapy.

Authors:  Ming-Wei Huang; Jian-Guo Zhang; Lei Zheng; Shu-Ming Liu; Guang-Yan Yu
Journal:  J Radiat Res       Date:  2016-07-15       Impact factor: 2.724

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.