Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT.

Yiannis Kyriakou1, Thomas Riedel, Willi A Kalender.   

Abstract

A side effect of increased volume coverage by using multi-row and flat-panel detectors in computed tomography (CT) is the concurrently growing contribution of scattered radiation to the measured signal. In order to investigate the effect of scatter on x-ray projections used for CT imaging, our study aimed at the development of a simulation tool for fast calculation of primary and scatter intensities. We developed a deterministic method to assess the contribution of single-scatter events to the measured signal. The investigation of multiple scatter by Monte Carlo simulations showed that it results in a smooth signal as compared to single scatter. A hybrid method is proposed in order to optimize the performance of the scatter simulation: a fast and exact analytical calculation of the single-scatter intensity combined with a coarse Monte Carlo (MC) estimate of multiple scatter to reduce overall computational expenses, while assuring an acceptable signal quality. The results of the hybrid simulation of total scatter were in excellent agreement with the corresponding MC only simulations, thereby allowing us to reduce computational time by orders of magnitude. Estimates of two-dimensional scatter distributions for flat-panel CT imaging took about 30-40 s (per projection). The hybrid method provides a realistic simulation of x-ray scatter and offers a basis for scatter correction approaches.

Mesh:

Year:  2006        PMID: 16953043     DOI: 10.1088/0031-9155/51/18/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  31 in total

1.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

Review 2.  PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques.

Authors:  Habib Zaidi; Issam El Naqa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-03-25       Impact factor: 9.236

3.  Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

Review 4.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

Review 5.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

6.  Noise suppression in scatter correction for cone-beam CT.

Authors:  Lei Zhu; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

7.  X-ray scatter correction method for dedicated breast computed tomography.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

Review 8.  [Basic principles of flat detector computed tomography (FD-CT)].

Authors:  Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

9.  Scatter correction for cone-beam CT in radiation therapy.

Authors:  Lei Zhu; Yaoqin Xie; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

10.  4D cone-beam computed tomography (CBCT) using a moving blocker for simultaneous radiation dose reduction and scatter correction.

Authors:  Cong Zhao; Yuncheng Zhong; Xinhui Duan; You Zhang; Xiaokun Huang; Jing Wang; Mingwu Jin
Journal:  Phys Med Biol       Date:  2018-05-29       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.