Literature DB >> 18807565

Abutment screw loosening in single-implant restorations: a systematic review.

Anna Theoharidou1, Haralampos P Petridis, Konstantinos Tzannas, Pavlos Garefis.   

Abstract

PURPOSE: The purpose of this study was to systematically review clinical studies on the incidence of abutment screw loosening in single-implant restorations with different implant-abutment connection geometries.
MATERIALS AND METHODS: The literature search was conducted using several electronic databases. Specific terms were used for the database search, which spanned the years 1990 to 2006. The search was augmented by using the option of "related articles" as well as hand searching of references and relevant journals. Relevant studies were selected according to predetermined inclusion and exclusion criteria. Agreement between reviewers was determined by using Cohen's kappa coefficients. Three-year complication-free rates (survival proportions) were calculated with the aid of a survival function, assuming constant failure rates. Summary estimates per group for complication-free rate after 3 years (M-estimator) were calculated using Tukey's biweight estimator.
RESULTS: The initial database search yielded 1,526 relevant titles. After the subsequent filtering process, 27 studies were finally selected. Interexaminer agreement ranged from good to perfect. The external-connection group comprised 12 studies following 586 single-implant restorations for a mean follow-up time that ranged from 3 to 5 years. The estimated percent of complication-free single-implant restorations after 3 years was 97.3% (95% CI: 95.6-98.3). The internal connection group comprised 15 studies following 1,113 single-implant restorations for a mean follow-up time that ranged from 3 to 10 years. The estimated percentage of complication-free single-implant restorations after 3 years was 97.6% (95% CI: 96.5-98.3).
CONCLUSION: The results show that abutment screw loosening is a rare event in single-implant restorations regardless of the geometry of implant-abutment connection, provided that proper antirotational features and torque are employed.

Mesh:

Year:  2008        PMID: 18807565

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  22 in total

1.  Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems.

Authors:  Jae-Young Jo; Dong-Seok Yang; Jung-Bo Huh; Jae-Chan Heo; Mi-Jung Yun; Chang-Mo Jeong
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

2.  Mechanical behavior of single-layer ceramized zirconia abutments for dental implant prosthetic rehabilitation.

Authors:  Manuel Jiménez-Melendo; Oriol Llena-Blasco; August Bruguera; Jaime Llena-Blasco; Rosa-María Yáñez-Vico; Manuel García-Calderón; Cristina Vaquero-Aguilar; Rocío Velázquez-Cayón; José-Luis Gutiérrez-Pérez; Daniel Torres-Lagares
Journal:  J Clin Exp Dent       Date:  2014-12-01

3.  Experimental study on the factors affecting torque of beam-type implant torque wrenches.

Authors:  Hiroki Shiba; Yuji Sato; Junichi Furuya; Tokiko Osawa; Akio Isobe; Myu Hayashi; Noboru Kitagawa
Journal:  BMC Oral Health       Date:  2021-07-15       Impact factor: 2.757

4.  Nonlinear finite element analysis of three implant- abutment interface designs.

Authors:  Chun-Bo Tang; Si-Yu Liul; Guo-Xing Zhou; Jin-Hua Yu; Guang-Dong Zhang; Yi-Dong Bao; Qiu-Ju Wang
Journal:  Int J Oral Sci       Date:  2012-06       Impact factor: 6.344

5.  Analytical and experimental position stability of the abutment in different dental implant systems with a conical implant-abutment connection.

Authors:  Wiebke Semper-Hogg; Silvan Kraft; Sebastian Stiller; Juergen Mehrhof; Katja Nelson
Journal:  Clin Oral Investig       Date:  2012-07-22       Impact factor: 3.573

6.  Effect of cyclic loading and retightening on reverse torque value in external and internal implants.

Authors:  Woong-Rae Cho; Yoon-Hyuk Huh; Chan-Jin Park; Lee-Ra Cho
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

7.  One-piece implant in reduced edentulous space closure: A report of two cases.

Authors:  Sunil Dutt Christopher; A N Savitha
Journal:  Contemp Clin Dent       Date:  2013-10

8.  A rationale method for evaluating unscrewing torque values of prosthetic screws in dental implants.

Authors:  Felipe Miguel Saliba; Mayra Cardoso; Marcelo Ferreira Torres; Alexandre Carvalho Teixeira; Eduardo José Veras Lourenço; Daniel de Moraes Telles
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

9.  Resistance of three implant-abutment interfaces to fatigue testing.

Authors:  Cleide Gisele Ribeiro; Maria Luiza Cabral Maia; Susanne S Scherrer; Antonio Carlos Cardoso; H W Anselm Wiskott
Journal:  J Appl Oral Sci       Date:  2011-07-01       Impact factor: 2.698

10.  Influence of the implant abutment types and the dynamic loading on initial screw loosening.

Authors:  Eun-Sook Kim; Soo-Yeon Shin
Journal:  J Adv Prosthodont       Date:  2013-02-28       Impact factor: 1.904

View more