Literature DB >> 25542245

Do the radial head prosthesis components fit with the anatomical structures of the proximal radioulnar joint?

Kilian Wegmann1, Moritz K Hain, Christian Ries, Wolfram F Neiss, Lars P Müller, Klaus J Burkhart.   

Abstract

PURPOSE: The fitting accuracy of radial head components has been investigated in the capitulo-radial joint, and reduced contact after prosthetic replacement of the radial head has been observed. The kinematics of the proximal radioulnar joint (PRUJ) are affected by radial head arthroplasty as well, but have not yet been investigated in this regard.
METHODS: The elbow joints of 60 upper extremities of formalin-fixed body donors were disarticulated to obtain a good view of the PRUJ. Each specimen was mounted on the examining table and radial head position in the native PRUJ was assessed in neutral position, full pronation, and full supination. Measurements were repeated after implantation of mono- and bi-polar prostheses.
RESULTS: Analysis of the distribution of the joint contacts in the compartments showed significant differences after radial head replacement. In comparison to the native joint, after bipolar and monopolar radial head replacement, the physiological shift of the proximal radius was altered. DISCUSSION: The physiological shift of the joint contact of the radial head from anterior to posterior during forearm rotation that was found in the native joint in our cadaver model was not observed after prosthetic replacement. With higher conformity and physiological kinematic of radial head prostheses, possibly lower shear forces and lower contact pressures would be generated. CLINICAL RELEVANCE: The tested radial head prostheses do not replicate the physiological kinematics of the radial head. Further development in the prosthesis design has to be made. The meticulous reconstruction of the annular ligament seems to be of importance to increase joint contact.

Entities:  

Mesh:

Year:  2014        PMID: 25542245     DOI: 10.1007/s00276-014-1407-2

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  18 in total

1.  The effect of metallic radial head arthroplasty on radiocapitellar joint contact area.

Authors:  Victor S Liew; Ian C Cooper; Louis M Ferreira; James A Johnson; Graham J W King
Journal:  Clin Biomech (Bristol, Avon)       Date:  2003-02       Impact factor: 2.063

2.  Morphometric parameters of the radial head: an anatomical study.

Authors:  T C Koslowsky; I Germund; F Beyer; K Mader; C F Krieglstein; J Koebke
Journal:  Surg Radiol Anat       Date:  2007-03-07       Impact factor: 1.246

3.  [Prosthesis after comminuted radial head fractures : midterm results].

Authors:  A Moghaddam; A Lennert; S Studier-Fischer; A Wentzensen; G Zimmermann
Journal:  Unfallchirurg       Date:  2008-12       Impact factor: 1.000

4.  Radiocapitellar joint contacts after bipolar radial head arthroplasty.

Authors:  Fabian Moungondo; Wissam El Kazzi; Roger van Riet; Véronique Feipel; Marcel Rooze; Frédéric Schuind
Journal:  J Shoulder Elbow Surg       Date:  2009-12-29       Impact factor: 3.019

5.  The anatomy of the proximal radioulnar joint.

Authors:  A P Weiss; H Hastings
Journal:  J Shoulder Elbow Surg       Date:  2009-02-25       Impact factor: 3.019

6.  Comminuted radial head fractures treated with a modular metallic radial head arthroplasty. Study of outcomes.

Authors:  Ruby Grewal; Joy C MacDermid; Kenneth J Faber; Darren S Drosdowech; Graham J W King
Journal:  J Bone Joint Surg Am       Date:  2006-10       Impact factor: 5.284

7.  Biomechanical and computer analysis of radial head prostheses.

Authors:  G G Gupta; G Lucas; D L Hahn
Journal:  J Shoulder Elbow Surg       Date:  1997 Jan-Feb       Impact factor: 3.019

8.  Midterm results with a bipolar radial head prosthesis: radiographic evidence of loosening at the bone-cement interface.

Authors:  Nebojsa Popovic; Roger Lemaire; Pierre Georis; Philippe Gillet
Journal:  J Bone Joint Surg Am       Date:  2007-11       Impact factor: 5.284

9.  Radial head arthroplasty with a modular metal spacer to treat acute traumatic elbow instability. Surgical technique.

Authors:  David Ring; Graham King
Journal:  J Bone Joint Surg Am       Date:  2008-03       Impact factor: 5.284

10.  The Essex-Lopresti lesion.

Authors:  K Wegmann; J Dargel; K J Burkhart; G P Brüggemann; L P Müller
Journal:  Strategies Trauma Limb Reconstr       Date:  2012-10-25
View more
  2 in total

1.  Proximal ulna fractures in adults: A review of diagnosis and management.

Authors:  Qazi Manaan Masood; Mahdi Qulaghassi; Urpinder Grewal; Rajesh Bawale; Madhavi Kammela; Bijayendra Singh
Journal:  J Clin Orthop Trauma       Date:  2021-06-20

2.  Validation of the contralateral side as reference for selecting radial head implant sizes.

Authors:  Paul W L Ten Berg; Johannes G G Dobbe; Gerhard van Wolfswinkel; Simon D Strackee; Geert J Streekstra
Journal:  Surg Radiol Anat       Date:  2016-01-21       Impact factor: 1.246

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.